Purpose: The objective is to show that TR-MRA is a useful non-invasive technique without ionizing radiation of traditional angiography in evaluating VMs.
Materials And Methods: Retrospective search utilizing M-Power for MRA studies done at 3 T (Trio, Siemens) with both 3D contrast enhanced TR-MRA and 3D CE-MRA sequences from 2009 to 2018 were obtained after IRB approval. The images were blindly reviewed by two experienced cardiovascular radiologists for informations regarding vascular malformations with the ability to separate arteries and veins without any overlay or contamination in real time.