This paper presents the historical fog climate dataset from 1886 to 1919 for Hungary and its neighbouring countries in the Carpathian Basin. The dataset was obtained from the yearbooks of the Royal Hungarian Central Institute of Meteorology and Earth Magnetism (RHCIMEM) established in 1870 to investigate the climatic features of Hungary during the time of the Austro-Hungarian Monarchy. Monthly observations were recorded from 1871 and daily observations were recorded from 1886.
View Article and Find Full Text PDFIntroduction: With advent of gallium-labeling somatostatin analogs and its evaluation under positron emission tomography-computed tomography, there has been a tremendous surge in its application. Gallium 68 can be made available either from onsite cyclotron production or in the form of ready-to-use Ge/Ga generators. Wherein setting up and running of cyclotron amounts to huge investment and dedicated team, the Ge/Ga generator has proved to be a better option and viable project.
View Article and Find Full Text PDFThis article briefly describes the event of a defective detector block in a daily quality assurance scan/blank scan and insists on implementing guidelines to scan or not to scan in such a scenario. The nuclear medicine physicist should have a clear understanding of the blank scan graph, which shall help rectify the right cause of problem and give confidence to the physician in reporting the acquired study. A routine blank scan in positron emission tomography signifies various parameters of the crystal (coincidence count rate, single count rate, dead time, and coincidence time along with energy response) and in some respect is analogous to the daily uniformity flood image for gamma cameras, providing an overall assessment of detector response.
View Article and Find Full Text PDFPurpose Of Study: The purpose of the study was to evaluate the effect of patient characteristics and equipment-related factors on the computed tomography (CT) dose received by patients from positron emission tomography-CT (PET-CT) using system-generated dose-length product (DLP) values and also to check the effective dose (ED) received from various CT protocols at our institute.
Materials And Methods: This retrospective study included 78 adult patients who underwent F-18 fluorodeoxyglucose whole-body PET-CT and were divided into three groups based on the area of primary cancerous lesion. In Group A, we had 44 patients who underwent PET-CT (head-and-neck protocol), in Group B, we had 24 patients who underwent PET-CT (whole body with brain protocol), and in Group C, we had 10 patients who underwent PET-CT (pelvis protocol).
Positron emission tomography/computed tomography (PET/CT) scanner is a state-of-art imaging device. Susceptibility of PET scanner in fluctuation environmental condition is known. Hence, every vendor prescribes the optimal conditions such as temperature and humidity to maintain the equipment in its best condition.
View Article and Find Full Text PDFAim: The aim of this study is to commission and validate the portal dosimetry (PD) system using an indirect method for flattening filter free (FFF) photon beam of the upgraded c-series linear accelerator.
Background: Varian Medical System clinacs with amorphous-silicon portal imager panel (aSi-1000) do not have PD for FFF beams. Recently, our c-series linear accelerator was upgraded to deliver 6MV FFF (6MVFFF) photon beam with the highest dose rate of 1400 monitor unit (MU)/min.
Objective: The purpose of this study is to develop a method to estimate the dose using amorphous silicon detector panel cone beam computed tomography (aSi-kVCBCT) for the OARs and targets in prostate radiotherapy and to compare with the actual planned dose. Methods: The aSi-kVCBCT is used widely in radiotherapy to verify the patient position before treatment. The advancement in aSi-kVCBCT combined with adaptive software allows us to verify the dose distribution in daily acquired CBCT images.
View Article and Find Full Text PDFIndian J Nucl Med
January 2018
A failure in any of the hardware components can lead to degradation in image quality and accuracy of quantification. Few artifacts may bring serious impacts on the image quality and finally lead to the wrong diagnosis. We encountered a sudden appearance of the cold area, being more prominently visible on Positron Emission Tomography image in comparison to the fused image.
View Article and Find Full Text PDFObjectives: To explore the feasibility of multi-isocentric 4π volumetric-modulated arc therapy (MI4π-VMAT) for the complex targets of head and neck cancers.
Methods: Twenty-five previously treated patients of HNC underwent re-planning to improve the dose distributions with either coplanar VMAT technique (CP-VMAT) or noncoplanar MI4π-VMAT plans. The latter, involving 3-6 noncoplanar arcs and 2-3 isocenters were re-optimized using the same priorities and objectives.
We present a case report of overlap of granulomatosis with polyangiitis (GPA; formerly known as Wegener's granulomatosis) and eosinophilic granulomatosis with polyangiitis (EGPA; formerly known as Churg-Strauss syndrome). We report a 45-year-old female who presented with rapidly progressive renal failure associated with fever, polyarthralgia, and respiratory symptoms with cytoplasmic antineutrophilic cytoplasmic antibody (ANCA) and proteinase (PR-3) antigen positivity. Computerized tomography scan of the chest showed diffuse alveolar hemorrhage with renal biopsy revealing pauci-immune necrotizing crescentic glomerulonephritis with intense eosinophilic infiltration suggestive of eosinophilic GPA (EGPA).
View Article and Find Full Text PDFAim: Purpose of this study is to dosimetrically compare head and neck (H and N) cancer patients planned with multivendor volumetric modulated arc therapy (VMAT) technology. VMAT treatment planning can be done using biological (treatment planning system [TPSB]: Monaco) or physical (TPSP: Eclipse)-based cost function optimization techniques. Planning and dosimetric comparisons were done in both techniques for H and N cases.
View Article and Find Full Text PDFObjective: The purpose of the study was to use deformable mapping of planning CT (pCT) electron density values on weekly cone-beam CT (CBCT) to quantify the anatomical changes and determine the dose-volume relationship in offline adaptive volumetric-modulated arc therapy.
Methods: 10 patients treated with RapidArc plans who had weekly CBCTs were selected retrospectively. The pCT was deformed to weekly CBCTs and the deformed contours were checked for any discrepancies.
J Appl Clin Med Phys
July 2015
The aim of this study is to assess the suitability of 5 mm millennium multileaf collimator (MMLC) for volumetric-modulated arc therapy (VMAT)-based lung stereotactic body radiotherapy (SBRT). Thirty lung SBRT patient treatment plans along with their planning target volumes (ranging from 2.01 cc to 150.
View Article and Find Full Text PDFBackground: The purpose of this study was to assess the dosimetric and clinical feasibility of volumetric modulated arc based hypofractionated stereotactic radiotherapy (RapidArc) treatment for large acoustic schwannoma (AS>10 cc).
Materials And Methods: Ten AS patients were immobilized using BrainLab mask. They were subject to multimodality imaging (magnetic resonance and computed tomography) to contour target and organs at risk (brainstem and cochlea).
Background: The purpose of this study was to assess the feasibility of deep inspiration breath-hold (DIBH) based volumetric modulated arc therapy (VMAT) for locally advanced left sided breast cancer patients undergoing radical mastectomy. DIBH immobilizes the tumor bed providing dosimetric benefits over free breathing (FB).
Materials And Methods: Ten left sided post mastectomy patients were immobilized in a supine position with both the arms lifted above the head on a hemi-body vaclock.
Purpose: To study the (18)F-FDG uptake pattern in brown adipose tissue (BAT) over an extended time period, by multiple-time-point fluorodeoxyglucose positron emission tomography (FDG-PET) imaging. The primary objective for this kind of research was that it could form a basis and may have further implications for obesity research, metabolic diseases and for cachexia of both malignant and benign origin.
Methods: A total of 12 patients who had undergone routine FDG-PET for disease evaluation and had demonstrated prominent BAT uptake in their baseline scans were selected.
Indian J Gastroenterol
January 2014
Mucocele of the appendix is an uncommon condition characterized by luminal distension and accumulation of a mucoid material. Occasionally, it can be caused due to malignancy like cystadenocarcinoma, and the preoperative diagnosis of which is very rare. We report a case of a 64-year-old lady presenting with intermittent abdominal pain diagnosed on ultrasonography as a mucocele where preoperative (18)F-flurodeoxyglucose positron emission tomography/computerized tomography (FDG PET/CT) findings raised a strong suspicion of malignancy.
View Article and Find Full Text PDFBackground: The accuracy of the two dose calculation engines available for RapidArc planning (both released for clinical use) is investigated in comparison to the COMPASS data.
Methods: Two dose calculation algorithms (Acuros-XB and Anisotropic Analytic Algorithm (AAA)) were used to calculate RA plans and compared to calculations with the Collapsed Cone Convolution algorithm (CC) from the COMPASS system (IBA Dosimetry). CC calculations, performed on patient data, are based on experimental fluence measurements with a 2D array of ion chambers mounted on the linac head.
Dyslipidemia is an important etiologic factor in the development of cardiovascular disease (CVD), which is a leading cause of death worldwide. As CVD begins in childhood, and as dyslipidemia is an important risk factor for CVD, screening and treatment of dyslipidemia in adolescents and children becomes an important health matter. This review deals with issues related to screening, diagnosis and treatment of dyslipidemia in children and adolescents.
View Article and Find Full Text PDF