We present the first clinical application of non-invasive stereotaxic radioablation of ventricular tachycardia (VT) refractory to medical and surgical treatment. Based on the results of invasive navigational activation mapping, a pericicatrical zone in the interventricular septum associated with VT was verified. Radiosurgical irradiation of the target in the region of the interventricular septum and the posterior apical segment of the left ventricle was performed on a TrueBeam linear electron accelerator (Varian) in accordance with the segmental scheme of the left ventricle.
View Article and Find Full Text PDFPurpose: Our study aimed to assess the achievement of target ablation index (AI) values and their impact on first-pass pulmonary vein isolation (FPI) as well as to identify FPI predictors.
Methods: Atrial fibrillation (AF) ablation was performed according to the local practice, and target AIs were evaluated. The actual AI was calculated as the median value of all ablation points for the anterior and posterior left atrial (LA) walls.
We developed a new technique of noninvasive stereotactic radioablation for the treatment of life-threatening tachyrhythmias. The study is performed on pigs (Sus scrofa domesticus). The zones of planned exposure were atrioventricular node (heart loading dose 40 Gy) and the apex of the left ventricle with a part of the interventricular septum (35 Gy) in animal No.
View Article and Find Full Text PDFThis review shows historical steps in the development of topical diagnostics for ventricular arrhythmias, the current status of this issue, and the relevance of developing topical, noninvasive electrophysiological cardiac mapping.
View Article and Find Full Text PDFThis is a prospective multicenter registry of atrial fibrillation (AF) ablation with the Ablation Index (AI) technology, which has been introduced as a marker predicting ablation lesion depth. The index incorporates the main parameters of radiofrequency point-by-point ablation: power, contact force, and time of ablation. The AI is calculated for every operator depending on personal skills, and there are no strict indications on the range of the parameter considering its safety and efficacy during pulmonary vein isolation.
View Article and Find Full Text PDFWe studied a biomaterial for a new domestic product, a biological envelope for implantation of cardiac electronic devices. The product is designed to prevent complications after pacemaker implantation and to facilitate the reimplantation procedure. By chemical and biological processing of raw materials (submucosa of porcine small intestine), an acellular extracellular collagen matrix was obtained.
View Article and Find Full Text PDF