Publications by authors named "Arsam Shiraz"

Online monitoring of electroencephalogram (EEG) signals is challenging due to the high volume of data and power requirements. Compressed sensing (CS) may be employed to address these issues. Compressed sensing using a sparse binary matrix, owing to its low power features, and reconstruction/decompression using spatiotemporal sparse Bayesian learning have been shown to constitute a robust framework for fast, energy efficient and accurate multichannel bio-signal monitoring.

View Article and Find Full Text PDF

Objective: Conventional treatment methods for migraine often have side effects. One treatment involves a wearable neuromodulator targeting frontal nerves. Studies based on this technique have shown limited efficacy and the existing setting can cause pain.

View Article and Find Full Text PDF

Objective: Conditional trans-rectal stimulation of the pudendal nerve could provide a viable solution to treat hyperreflexive bladder in spinal cord injury. A set threshold of the amplitude estimate of the external anal sphincter surface electromyography (sEMG) may be used as the trigger signal. The efficacy of such a device should be tested in a large scale clinical trial.

View Article and Find Full Text PDF

Objective: Colorectal cancer is the fourth most common cancer worldwide, with a lifetime risk of around 20%. Current techniques do not allow clinicians to objectively assess tissue abnormality during endoscopy and perioperatively. A method capable of objectively assessing samples in real time and which can be included in minimally invasive diagnostic and management strategies would be highly transformative.

View Article and Find Full Text PDF

After spinal cord injury, lower urinary tract functions may be disrupted. Trans-rectal stimulation of the pudendal nerve may enable patients to regain these functions via minimally invasive means. Using a finite element model of a wearable trans-rectal stimulator in the pelvic region, and a computational model of mammalian nerve fiber, various electrode configurations and the corresponding required current levels were studied.

View Article and Find Full Text PDF

After spinal cord injury, functions of the lower urinary tract may be disrupted. A wearable device with surface electrodes which can effectively control the bladder functions would be highly beneficial to the patients. A trans-rectal pudendal nerve stimulator may provide such a solution.

View Article and Find Full Text PDF