Publications by authors named "Arnt E Fiane"

Background: Pregnant women with COVID-19 are probably at increased risk of serious illness. The objective of this study was to describe the course of illness in pregnant women admitted to the intensive care unit (ICU) with acute respiratory distress syndrome triggered by COVID-19.

Material And Method: Pregnant women with COVID-19 were registered on admission to an ICU at Rikshospitalet, Oslo University Hospital in the period March 2020 to May 2023.

View Article and Find Full Text PDF

Aims: Heart failure is a condition with high mortality rates, and there is a lack of therapies that directly target maladaptive changes in the extracellular matrix (ECM), such as fibrosis. We investigated whether the ECM enzyme known as A disintegrin and metalloprotease with thrombospondin motif (ADAMTS) 4 might serve as a therapeutic target in treatment of heart failure and cardiac fibrosis.

Methods And Results: The effects of pharmacological ADAMTS4 inhibition on cardiac function and fibrosis were examined in rats exposed to cardiac pressure overload.

View Article and Find Full Text PDF

Background: Left ventricular assist devices (LVAD) provide circulatory blood pump support for severe heart failure patients. Pump inflow obstructions may lead to stroke and pump malfunction. We aimed to verify in vivo that gradual inflow obstructions, representing prepump thrombosis, are detectable by a pump-attached accelerometer, where the routine use of pump power (P) is deficient.

View Article and Find Full Text PDF

Background: COVID-19 can lead to acute respiratory distress syndrome (ARDS). In some patients for whom conventional mechanical ventilation is insufficient, venovenous (VV) extracorporeal membrane oxygenation (ECMO) can be life-saving.

Material And Method: Retrospective analysis of data from patients with ARDS triggered by COVID-19 who received ECMO therapy between March 2020 and February 2022.

View Article and Find Full Text PDF

We have previously demonstrated that accelerometer-based vibration analysis detects thromboembolism and pump thrombosis in HeartWare Left Ventricular Assist Device (HVAD) using the third harmonic frequency (pump_speedx3). Thromboembolism also affected the amplitude of the nonharmonic frequencies. The aim of this study was to determine whether nonharmonic-amplitude (NHA) analysis can improve the diagnosis of thromboembolic complications.

View Article and Find Full Text PDF

Objectives: The objective was to analyse associations between obesity and outcomes after left ventricular assist device (LVAD) implantation.

Methods: A retrospective analysis of the EUROMACS Registry was performed. Adult patients undergoing primary implantation of a continuous-flow LVAD between 2006 and 2019 were included (Medtronic HeartWare® HVAD®, Abbott HeartMate II®, Abbott HeartMate 3™).

View Article and Find Full Text PDF

Heart failure with preserved ejection fraction (HFpEF) is increasing in prevalence and represents approximately 50% of all heart failure (HF) patients. Patients with this complex clinical scenario, characterized by high filling pressures, and reduced cardiac output (CO) associated with progressive multi-organ involvement, have so far not experienced any significant improvement in quality of life or survival with traditional HF treatment. Left ventricular assist devices (LVAD) have offered a new treatment alternative in terminal heart failure patients with reduced ejection fraction (HFrEF), providing a unique combination of significant pressure and volume unloading together with an increase in CO.

View Article and Find Full Text PDF

Background: While expected need for intensive care after lung transplantation (LTx) does not normally affect organ allocation, it would be useful to estimate whether intensive care capacity is limited. The aim of this study was to assess factors available before LTx to identify predictors of prolonged intensive care unit (ICU) length of stay (LOS) after LTx.

Methods: All bilateral LTx recipients excluding re-transplantation and multi-organ transplantation at Oslo University Hospital from 2000 to 2013 were included (n = 277).

View Article and Find Full Text PDF

Circulating compounds such as drugs and nutritional components might adhere to the oxygenator fibers and tubing during ECMO support. This study evaluated the amount of nutritional supplements adsorbed to the ECMO circuit under controlled ex vivo conditions. Six identical ECMO circuits were primed with fresh human whole blood and maintained under physiological conditions at 36 °C for 24 h.

View Article and Find Full Text PDF

Background: Heart transplantation is limited by the scarcity of suitable donors. Patients with advanced biventricular failure may require biventricular support to provide optimal cardiac output and end-organ perfusion. We highlight the outcomes of using the HeartWare HVAD System (HVAD) in a biventricular configuration.

View Article and Find Full Text PDF

Background: The paucity of available hearts for transplantation means that more patients remain on durable left ventricular support for longer periods of time. The Registry to Evaluate the HeartWare Left Ventricular Assist System was an investigator-initiated multicenter, prospective, single-arm database established to collect post-Conformité Européene mark clinical information on patients receiving the HeartWare ventricular assist device system as a bridge to transplantation. This registry represents the longest multicenter follow-up of primary left ventricular assist device outcomes.

View Article and Find Full Text PDF

We report 2 continuous flow HeartWareTM left ventricular assist devices successfully used in a patient with advanced heart failure of giant cell myocarditis origin in a biventricular configuration. Despite technical challenges of adapting a left ventricular assist device engineered for systemic pressure to function as a right ventricular assist device, the addition of dynamic banding on the right ventricular assist device outflow graft allowed successful adaptation of afterload. This patient has now been on biventricular configuration support for 9 years, and remains stable to this day.

View Article and Find Full Text PDF

Objective: Current understanding of the prognostic impact of depression on mortality after heart transplantation (HTx) is limited. We examined whether depression after HTx is a predictor of mortality during extended follow-up. Subsequently, we explored whether different symptom dimensions of depression could be identified and whether they were differentially associated with mortality.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to assess complications and mortality and its predictors, with continuous-flow left ventricular assist devices (CF-LVADs) in the Nordic Countries.

Design: This was a retrospective, international, multicenter cohort study.

Results: Between 1993 and 2013, 442 surgically implanted long-term mechanical assist devices were used among 8 centers in the Nordic countries.

View Article and Find Full Text PDF

We have recently demonstrated that accelerometer-based pump thrombosis and thromboembolic events detection is feasible in vitro. This article focuses on detection of these conditions in vivo. In an open-chest porcine model (n = 7), an accelerometer was attached to the pump casing of an implanted HeartWare HVAD.

View Article and Find Full Text PDF

Background: Three-dimensional (3D) echocardiography with multiplanar reconstruction (MPR) is used clinically to quantify the mitral annulus. MPR images are, however, presented on a two-dimensional screen, calling into question their accuracy. An alternative to MPR is an autostereoscopic holographic display that enables in-depth visualization of 3D echocardiographic data without the need for special glasses.

View Article and Find Full Text PDF

Background: Throughout the world, the scarcity of donor organs makes optimal allocation systems necessary. In the Scandiatransplant countries, organs for lung transplantation are allocated nationally. To ensure shorter wait time for critically ill patients, the Scandiatransplant urgent lung allocation system (ScULAS) was introduced in 2009, giving supranational priority to patients considered urgent.

View Article and Find Full Text PDF

Background: Donation after circulatory death (DCD) can increase the pool of available organs for transplantation. This pilot study evaluates the implementation of a controlled DCD (cDCD) protocol using normothermic regional perfusion in Norway.

Methods: Patients aged 16 to 60 years that are in coma with documented devastating brain injury in need of mechanical ventilation, who would most likely attain cardiac arrest within 60 minutes after extubation, were eligible.

View Article and Find Full Text PDF

Targeted temperature management is part of the standardized treatment for patients in cardiac arrest. Hypothermia decreases cerebral oxygen consumption and induces bradycardia; thus, increasing the heart rate may be considered to maintain cardiac output. We hypothesized that increasing heart rate during hypothermia would impair diastolic function.

View Article and Find Full Text PDF

Background: Assessment of qualitative or subjective image quality in radiology is traditionally performed using a fixed-point scale even though reproducibility has proved challenging.

Objective: Image quality of 3-T coronary magnetic resonance (MR) angiography was evaluated using three scoring methods, hypothesizing that a continuous scoring scale like visual analogue scale would improve the assessment.

Materials And Methods: Adolescents corrected for transposition of the great arteries with arterial switch operation, ages 9-15 years (n=12), and healthy, age-matched controls (n=12), were examined with 3-D steady-state free precession magnetic resonance imaging.

View Article and Find Full Text PDF

Pump thrombosis and stroke are serious complications of left ventricular assist device (LVAD) support. The aim of this study was to test the ability of an accelerometer to detect pump thrombosis and thromboembolic events (TEs) using real-time analysis of pump vibrations. An accelerometer sensor was attached to a HeartWare HVAD and tested in three in vitro experiments using different pumps for each experiment.

View Article and Find Full Text PDF

Background: Cognitive impairment is documented early after heart transplantation (HTx), but we lack data on cognitive function beyond the fourth year post-transplant. Against the background of good long-term survival, this knowledge is necessary to improve clinical care throughout the entire post-transplant period.

Methods: We assessed cognitive function with a neuropsychological test battery in a sample of HTx recipients ≥16 years post-transplant.

View Article and Find Full Text PDF

Introduction: The use of cardiopulmonary bypass is associated with a risk of neurocognitive deficit caused by gaseous microemboli. Flushing the empty bypass circuit with carbon dioxide, which is more soluble than air, may reduce the amount of gaseous microemboli in the priming solution before the initiating of cardiopulmonary bypass.

Method: We measured the amount of gaseous microemboli in twenty primed bypass circuits.

View Article and Find Full Text PDF

In dilated cardiomyopathy (DCM), adverse myocardial remodeling is essential, potentially involving Notch signaling. We hypothesized that secreted Notch ligands would be dysregulated in DCM. We measured plasma levels of the canonical Delta-like Notch ligand 1 (DLL1) and non-canonical Notch ligands Delta-like 1 homologue (DLK1) and periostin (POSN) in 102 DCM patients and 32 matched controls.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessiont5o6v6eosbfbs74ga42l9ppv5l05mg8l): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once