Stereotact Funct Neurosurg
January 2016
Background: Placement accuracy of ventriculostomy catheters is reported in a wide and variable range. Development of an efficient image-guidance system may improve physician performance and patient safety.
Objective: We evaluate the prototype of Smart Stylet, a new electromagnetic image-guidance system for use during bedside ventriculostomy.
Objective: The objective of our study was to retrospectively compare the MRI characteristics of surgically confirmed healed and unhealed peripheral vertical meniscal tears.
Materials And Methods: The study group consisted of 64 patients with 86 peripheral vertical meniscal tears diagnosed on MRI who subsequently underwent knee surgery. The MRI examinations were retrospectively reviewed to assess the following tear characteristics: tear location relative to the meniscocapsular junction, tear width, tear length, tear extension through one or both surfaces, sequences on which tear was visualized, signal intensity of tear on T2-weighted imaging, and presence of low-signal-intensity strands bridging the tear on T2-weighted imaging.
Purpose: To determine inter-scan, inter-reader and intra-reader variability of trabecular structure analysis using flat-panel volume computed tomography (fp-VCT) in cadaver knee specimens.
Methods: Five explanted knee specimens were imaged at three different time points using fp-VCT. Four parameters that quantify trabecular bone structure of the proximal tibia were measured by two observers at two different time points.
Purpose: To examine trabecular microarchitecture with high-resolution flat-panel volume computed tomography (CT) and bone mineral density (BMD) with dual-energy x-ray absorptiometry (DXA) in adolescent girls with anorexia nervosa (AN) and to compare these results with those in normal-weight control subjects.
Materials And Methods: The study was approved by the institutional review board and complied with HIPAA guidelines. Informed consent was obtained.
Flat-panel volume computed tomography (CT) systems have an innovative design that allows coverage of a large volume per rotation, fluoroscopic and dynamic imaging, and high spatial resolution that permits visualization of complex human anatomy such as fine temporal bone structures and trabecular bone architecture. In simple terms, flat-panel volume CT scanners can be thought of as conventional multidetector CT scanners in which the detector rows have been replaced by an area detector. The flat-panel detector has wide z-axis coverage that enables imaging of entire organs in one axial acquisition.
View Article and Find Full Text PDFFlat-panel volume computed tomography (fpVCT) is a recent development in imaging. We discuss some of the musculoskeletal applications of a high-resolution flat-panel CT scanner. FpVCT has four main advantages over conventional multidetector computed tomography (MDCT): high-resolution imaging; volumetric coverage; dynamic imaging; omni-scanning.
View Article and Find Full Text PDFObjective: A systematic approach to the consideration of various factors on outcome demands a comprehensive grading system for patients with intracranial aneurysms. We have previously identified potential patient- and lesion-specific factors that correlate strongly with outcome after treatment for intracranial aneurysms, and we have developed a comprehensive grading system based on these factors. In this study, we evaluate this grading system in a large series of aneurysm patients treated by surgery and endovascular therapy.
View Article and Find Full Text PDFIntroduction: Decompressive craniectomy has demonstrated efficacy in reducing morbidity and mortality in critically ill patients with massive hemispheric cerebral infarction. However, little is known about the patterns of functional recovery that exist in patients after decompressive craniectomy, and controversy still exists as to whether craniotomy and infarct resection ("strokectomy") are appropriate alternatives to decompression alone. We therefore used functional magnetic resonance imaging (f-MRI) to assess the extent and location of functional recovery in patients after decompressive craniectomy for massive ischemic stroke.
View Article and Find Full Text PDFThe validity, reproducibility, and specificity of patch-testing in the diagnosis of allergic contact dermatitis (ACD) have repeatedly been addressed. In vivo reflectance confocal microscopy (RCM) has been used for real-time evaluation of the histopathologic features of ACD. This pilot study was designed to determine the sensitivity and specificity of RCM in diagnosing ACD in reference to patch-testing.
View Article and Find Full Text PDFObjective And Importance: The coexistence of spinal arteriovenous malformation (AVM) with congenital abnormalities is relatively common. However, the association of a spinal AVM and lipoma is rare. We present an adult patient with this combined anomaly and discuss the clinical relevance of this case.
View Article and Find Full Text PDFReflectance confocal microscopy (RCM) allows non-invasive visualization of human skin in vivo. It has been used to describe the histopathological features of acute contact dermatitis (CD). This work was designed to investigate the kinetics of both allergic and irritant CD (ACD and ICD) in vivo.
View Article and Find Full Text PDFObjective: At many centers, patients undergo both computed tomographic angiography (CTA) and digital subtraction angiography (DSA). This practice negates most of the advantages of CTA, and it renders the risks and disadvantages of the two techniques additive. Previous reports in the literature have assessed the sensitivity and specificity of CTA compared with DSA; however, these investigations have not analyzed the clinical implications of a protocol that replaces DSA with CTA as the only diagnostic and pretreatment planning study for patients with cerebral aneurysms.
View Article and Find Full Text PDF