Backing materials with tailored acoustic properties are beneficial for miniaturized ultrasonic transducer design. Whereas piezoelectric P(VDF-TrFE) films are common elements in high-frequency (>20 MHz) transducer design, their low coupling coefficient limits their sensitivity. Defining a suitable sensitivity-bandwidth trade-off for miniaturized high-frequency applications requires backings with impedances of >25 MRayl and strongly attenuating to account for miniaturized requirements.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
February 2023
An innovative processing to deposit P(VDF-TrFE) film on silicon wafers by an inkjet printing method was used to fabricate high-frequency annular array prototype. This prototype has a total aperture of 7.3 mm and 8 active elements.
View Article and Find Full Text PDFThe objective of this study was to determine the accuracy of an echographic method for measuring the change in leg muscle volume against the gold standard, magnetic resonance imaging (MRI). Leg muscle volume was measured using an echographic scanner, which consisted of two metallic rails on which a probe holder moved via an electric engine. Ten to 20 transverse muscle views were collected along the area scanned, and the muscle cross-sectional area (CSA, cm2) was measured on each of them.
View Article and Find Full Text PDFObjective: The purpose of this study was to design and validate a method of performing sonography between an expert center and an isolated site. A sonography probe is held on the patient by a robotic arm and remotely controlled from the expert's center. The robotic arm reproduces all the movements of the expert's dummy probe on the patient probe.
View Article and Find Full Text PDFObjective: The objectives of this preliminary work were to evaluate the distribution of an ultrasound contrast agent (UCA) (microbubbles) in different arterial regions (brain, kidney, lower limbs) using the Doppler spectrum brightness analysis and to discuss the results in the context of decompression physiology.
Method: There were four patients who instrumented with two pulsed Doppler sensors in order to monitor in real-time the spectrum of the middle cerebral femoral arteries. Renal arteries were investigated using an echo-Doppler probe handled by a sonographer.
The objectives to determine both the contribution to orthostatic intolerance (OI) of calf venous volume during a stand-test, and the effects of a combined eccentric-concentric resistance exercise countermeasure on both vein response to orthostatic test and OI, after 90-day head-down tilt bed-rest (HDT). The subjects consisted of a control group (Co-gr, n = 9) and an exercise countermeasure group (CM-gr, n = 9). Calf volume and vein cross-sectional area (CSA) were assessed by plethysmography and echography during pre- and post-HDT stand-tests.
View Article and Find Full Text PDF