Publications by authors named "Arnaud Barre"

Musculoskeletal models generally solve the muscular redundancy by numerical optimisation. They have been extensively validated using instrumented implants. Conversely, a reduction approach considers only one flexor or extensor muscle group at the time to equilibrate the inter-segmental joint moment.

View Article and Find Full Text PDF

Roentgen stereophotogrammetry analysis technique allows an accurate measurement of knee joint prosthesis position and orientation using two X-ray images. Although this technique is used generally during static procedure, it is possible to use it with a biplane fluoroscopic system to measure the prosthesis kinematics during functional tasks (e.g.

View Article and Find Full Text PDF

The estimation of joint kinematics from skin markers is hindered by the soft tissue artefact (STA), a well-known phenomenon although not fully characterized. While most assessments of the STA have been performed based on the individual skin markers displacements, recent assessments were based on the marker-cluster geometrical transformations using, e.g.

View Article and Find Full Text PDF

Soft tissue artefact (STA) represents one of the main obstacles for obtaining accurate and reliable skeletal kinematics from motion capture. Many studies have addressed this issue, yet there is no consensus on the best available bone pose estimator and the expected errors associated with relevant results. Furthermore, results obtained by different authors are difficult to compare due to the high variability and specificity of the phenomenon and the different metrics used to represent these data.

View Article and Find Full Text PDF

The aim of this study was to analyze the accuracy of bone pose estimation based on sub-clusters of three skin-markers characterized by triangular Cosserat point elements (TCPEs) and to evaluate the capability of four instantaneous physical parameters, which can be measured non-invasively in vivo, to identify the most accurate TCPEs. Moreover, TCPE pose estimations were compared with the estimations of two least squares minimization methods applied to the cluster of all markers, using rigid body (RBLS) and homogeneous deformation (HDLS) assumptions. Analysis was performed on previously collected in vivo treadmill gait data composed of simultaneous measurements of the gold-standard bone pose by bi-plane fluoroscopy tracking the subjects' knee prosthesis and a stereophotogrammetric system tracking skin-markers affected by soft tissue artifact.

View Article and Find Full Text PDF

Functional calibration methods were devised to improve repeatability and accuracy of the knee flexion-extension axis, which is used to define the medio-lateral axis of the femur coordinate system in gait analysis. Repeatability of functional calibration methods has been studied extensively in healthy individuals, but not accuracy in the absence of a benchmark knee axis. We captured bi-plane fluoroscopy data of the knee joint in 17 subjects with unilateral total knee arthroplasty during treadmill walking.

View Article and Find Full Text PDF

Segment poses and joint kinematics estimated from skin markers are highly affected by soft tissue artifact (STA) and its rigid motion component (STARM). While four marker-clusters could decrease the STA non-rigid motion during gait activity, other data, such as marker location or STARM patterns, would be crucial to compensate for STA in clinical gait analysis. The present study proposed 1) to devise a comprehensive average map illustrating the spatial distribution of STA for the lower limb during treadmill gait and 2) to analyze STARM from four marker-clusters assigned to areas extracted from spatial distribution.

View Article and Find Full Text PDF

C3D file format is widely used in the biomechanical field by companies and laboratories to store motion capture systems data. However, few software packages can visualize and modify the integrality of the data in the C3D file. Our objective was to develop an open-source and multi-platform framework to read, write, modify and visualize data from any motion analysis systems using standard (C3D) and proprietary file formats (used by many companies producing motion capture systems).

View Article and Find Full Text PDF

The primary purpose of this study was to investigate the effects of cognitive loading on movement kinematics and trajectory formation during goal-directed walking in a virtual reality (VR) environment. The secondary objective was to measure how participants corrected their trajectories for perturbed feedback and how participants' awareness of such perturbations changed under cognitive loading. We asked 14 healthy young adults to walk towards four different target locations in a VR environment while their movements were tracked and played back in real-time on a large projection screen.

View Article and Find Full Text PDF

Accurate measurement of knee kinematics during functional activities suffers mainly from soft tissue artifact (STA): the combination of local surface deformations and rigid movement of markers relative to the underlying bone (also called rigid STA movement: RSTAM). This study proposes to assess RSTAM on the thigh, shank, and knee joint and to observe possible features between subjects. Nineteen subjects with knee arthroplasty were asked to walk on a treadmill while a biplane fluoroscopic system (X-rays) and a stereophotogrammetric system (skin markers) recorded their knee movement.

View Article and Find Full Text PDF

Model-based mono-planar and bi-planar 3D fluoroscopy methods can quantify intact joints kinematics with performance/cost trade-off. The aim of this study was to compare the performances of mono- and bi-planar setups to a marker-based gold-standard, during dynamic phantom knee acquisitions. Absolute pose errors for in-plane parameters were lower than 0.

View Article and Find Full Text PDF