Alternatives to phlebotomy in clinical trials increase options for patients and clinicians by simplifying and increasing accessibility to clinical trials. The authors investigated the technical and logistical considerations of one technology compared with phlebotomy. Paired samples were collected from 16 donors via a second-generation serum gel microsampling device and conventional phlebotomy.
View Article and Find Full Text PDFOutsourcing is a common strategy across the pharmaceutical industry and clinical research. CROs offer many choices for selecting outsourcing partners for bioanalytical and biomarker support. We aimed this paper to provide critical insights into CRO benchmarking and selection using a bioanalytical challenge approach performing fit-for-purpose ligand-binding assay.
View Article and Find Full Text PDFEvaluation of a novel microsampling device for its use in clinical sample collection and biomarker analysis. Matching samples were collected from 16 healthy donors (ten females, six males; age 42 ± 20) via K2EDTA touch activated phlebotomy (TAP) device and phlebotomy. The protein profile differences between sampling groups was evaluated using aptamer-based proteomic assay SomaScan and selected ELISA.
View Article and Find Full Text PDFThis paper presents a study of the signal suppression and enhancement effects in assays based on HPLC-ESI-MS/MS detection. The major focus was to investigate the effect of signal suppression/enhancement of typical co-administered (concomitant) medications, i.e.
View Article and Find Full Text PDFA novel approach for on-line introduction of internal standard (IS) for quantitative analysis using LC-MS/MS has been developed. In this approach, analyte and IS are introduced into the sample injection loop in different steps. Analyte is introduced into the injection loop using a conventional autosampler (injector) needle pickup from a sample vial.
View Article and Find Full Text PDFA technique using a fully automated on-line solid phase extraction (SPE) system (Symbiosis, Spark Holland) combined with liquid chromatography (LC)-mass spectrometry (MS/MS) has been investigated for fast bioanalytical method development, method validation and sample analysis using both conventional C18 and monolithic columns. Online SPE LC-MS/MS methods were developed in the automated mode for the quantification of model compounds (propranolol and diclofenac) directly in rat plasma. Accuracy and precision using online SPE LC-MS/MS with conventional C18 and monolithic columns were in the range of 88-111% and 0.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
October 2005
Large volume injection (LVI) has systematically been studied to improve LC-MS/MS sensitivity (signal-to-noise ratio, or S/N) and detection limits. The method of LVI was combined with on-line solid phase extraction (on-line SPE) and LC-MS/MS detection for analysis of compounds directly in plasma. It was demonstrated that LVI of plasma with on-line SPE-LC-MS/MS allows for improvement of sensitivity and detection limits without compromising chromatographic peak shape and resolution and inducing significant matrix and signal suppression effects.
View Article and Find Full Text PDFThis review focuses on the application of matrix assisted laser desorption/ionization (MALDI) mass spectrometry to the characterization of molecules in the low mass range (<1500 Da). Despite its reputation to the contrary, MALDI is a powerful technique to provide both qualitative and quantitative determination of low molecular weight compounds. Several approaches to minimize interference via sample preparation and matrix selection are discussed, as well as coupling of MALDI to liquid and planar chromatographic techniques to extend its range of applicability.
View Article and Find Full Text PDF