We propose a novel x-ray fluorescence imaging setup for the in vivo detection of high-Z tracer distributions. The main novel aspect is the use of an analyzer-based, energy-resolved detection method together with a radial, scatter reducing collimator. The aim of this work is to show the feasibility of this method by measuring the Bragg reflected K-fluorescence signal of an iodine solution sample in a proof of principle experiment and to estimate the potential of the complete imaging setup using a Monte Carlo simulation, including a quantification of the minimal detectable tracer concentration for in vivo imaging.
View Article and Find Full Text PDFXRF (X-ray fluorescence) is a powerful technique for elemental analysis with a high sensitivity. The resolution is presently limited by the size of the primary excitation X-ray beam. A test-bed for confocal-type XRF has been developed to estimate the ultimate lateral resolution which could be reached in chemical mapping using this technique.
View Article and Find Full Text PDFFor many applications there is a requirement for nondestructive analytical investigation of the elemental distribution in a sample. With the improvement of X-ray optics and spectroscopic X-ray imagers, full field X-ray fluorescence (FF-XRF) methods are feasible. A new device for high-resolution X-ray imaging, an energy and spatial resolving X-ray camera, is presented.
View Article and Find Full Text PDFPhotoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional x-ray optical module which converts the polychromatic, fan-shaped CT beam into a monochromatized and focused beam for energy-tuned photoelectric-enhanced radiotherapy. A dedicated x-ray optical module designed for spatial collimation, focusing, and monochromatization was mounted at the exit of the x-ray tube of a clinical CT unit.
View Article and Find Full Text PDFIntroduction: Computed tomography (CT) is a widespread and highly precise technique working in the energy range around 50-100 keV. For radiotherapy, however, the MeV energy range enables a better dose distribution. This gap between diagnosis and therapy can be overcome by the use of a modified CT machine in combination with heavy elements targeted to the tumour and used as photoelectric radiation enhancer.
View Article and Find Full Text PDFObjective: Atypical antipsychotic medications have largely supplanted their typical counterparts, both for psychosis and for the treatment of aggression and/or self-injurious behaviour (SIB), in persons with intellectual disabilities (ID). However, with the exception of risperidone, little systematic research supports their use in such persons.
Method: A retrospective review of 31 adult residents of a state developmental centre, who were treated for aggression and/or SIB with atypical antipsychotics.
Thin films of highly oriented pyrolytic graphite (HOPG) give the opportunity to realize crystal optics with arbitrary geometry by mounting it on a mould of any shape. A specific feature of HOPG is its mosaicity accompanied by a high integral reflectivity, which is by an order of magnitude higher than that of all other known crystals in an energy range between 2 keV up to several 10 keV. These characteristics make it possible to realize highly efficient collecting optics, which could be also relevant for compact x-ray diagnostic tools and spectrometers.
View Article and Find Full Text PDFBy the use of a thin highly oriented pyrolytic graphite crystal (HOPG) bent to a high-performance ellipsoidal shape it was possible to focus monochromatic x-rays of 4.5 keV photon energy with an efficiency of 0.0033, which is 30 times larger than for previously used bent crystals.
View Article and Find Full Text PDFRationale And Background: The emission spectrum of an x-ray tube is determined by the anode and filter materials as well as by the high voltage being used. For mammography, typical anode materials are molybdenum (Mo), rhodium (Rh), and tungsten (W); molybdenum, rhodium, and aluminum are favored for filters. Mammography is a soft tissue imaging modality demanding a high spatial resolution as well as a high detector sensitivity.
View Article and Find Full Text PDFX-ray spectra are composed of a broad bremsspectrum and anode-characteristic emission lines. In mammography typically molybdenum (Mo), rhodium (Rh) or tungsten (W) anodes are used in combination with Mo, Rh or aluminium filters. Only the photons with energies between 17 and 22 keV of the resulting spectrum are suitable for the soft tissue imaging needed for mammography.
View Article and Find Full Text PDFCopolymers of N-polyvinylpyrrolidone-acrylic acid (AB-1) and adamantane derivatives are known to possess marked antiviral activity in in vitro and in ovo models. Among the constructed preparations of AB-1 modified by adamantane derivatives some, especially AB-4 (modified by deitiforin), were found to show more extended antiviral activity and to inhibit markedly virus reproduction in susceptible permissive cell cultures and chicken embryos. In AB-4 treated cells and allantoic sacs, virus titers (influenza virus, herpes virus, and HIV) and virus antigen concentration were decreased.
View Article and Find Full Text PDFPresence of influence of Bacillus subtilis during peroral and parenteral administration upon the laboratory animals' immune system has been studied. Absence of immuno-depressing action of the bacillus culture under study has been presented with the help of assessment tests on the humoral response to the thymus-dependent antigen: creation of the antibodies, and the delayed-onset hypersensitivity reaction. An insignificant stimulating effect has been revealed under execution of the reaction of the delayed-onset hypersensitivity as a result of B.
View Article and Find Full Text PDF