Objective: To evaluate the effect of anterior repositioning splint (ARS) on maximum bite force (MBF) values in patients with disc interference disorders (DID).
Material And Methods: Twenty-two patients with disc interference disorders and 22 healthy subjects participated in to study. The Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I have been used to diagnose DID patients.
Purpose: To determine the effectiveness of anterior repositioning splint (ARS) therapy on elimination of temporomandibular joint (TMJ) sounds in patients with internal derangement.
Materials And Methods: A total of 26 patients with 44 TMJs with internal derangement according to the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) were selected. These patients used an ARS for 6 weeks.
Purpose: Dual-cure core build-up resins have been developed to take advantages of both self and light-cured resin. The aim of present study was to determine the polymerization characteristics of self and dual-cured modes of dual-cure core build-up composites evaluating degree of conversion (DC) and crosslink density by measurement of glass-transition temperature (Tg) and hardness decrease in ethanol.
Methods: Clearfil Dc Core Automix (CLF) and Grandio Core Dc (GR) core build-up resins were selected.
The aim of the present study was to compare the effects of some disinfectants, including ethanol extract of propolis (EEP), on the adhesion of Candida albicans to denture base resins. Seventy-two acrylic resin samples were prepared, half of which was polished and the other half was roughened. C.
View Article and Find Full Text PDFObjectives: The purpose of the present study was to compare craniofacial morphology and bite force of bruxist patients with signs and symptoms of temporomandibular disorders.
Method: Fourteen subjects with sleep bruxism and 14 healthy subjects participated. The signs and symptoms of the temporomandibular disorders were identified according to the Craniomandibular Index (CMI).
Purpose: The occlusal splint has been used for many years as an effective treatment of sleep bruxism. Several methods have been used to evaluate efficiency of the occlusal splints. However, the effect of the occlusal splints on occlusal force has not been clarified sufficiently.
View Article and Find Full Text PDFPurpose: This study evaluated the adhesion to acrylic resin specimens and biofilm formation capability of Candida albicans strains isolated from HIV positive subjects' oral rinse solutions.
Materials And Methods: The material tested was a heat-cured acrylic resin (Acron Duo). Using the adhesion and crystal violet assays, 14 oral Candida albicans isolated from HIV-positive subjects and 2 references Candida strains (C.
The case report describes the occlusal rehabilitation of a male patient with Angle Class III malocclusion and its effect on maximum bite force. The main complaints of patient were masticatory difficulty and poor esthetic. The patient's expectations from the treatment were a good esthetic and function with a less invasive and relatively promptly way.
View Article and Find Full Text PDFMed Oral Patol Oral Cir Bucal
January 2014
Objectives: Acromegaly is a metabolic disorder caused by increased growth hormone secretion. As a consequence of acromegaly some typical craniofacial morphology changes appear. This pilot study was conducted to compare the bite force and the characteristic size and shape of the craniofacial components of acromegalic patients with the healthy Turkish individuals.
View Article and Find Full Text PDFPurpose: The purpose of this study was to explore the effects of implant angulation and its possible influence on prosthetic connection as regards implant/tooth strains in a combined implant and natural tooth abutment fixed partial denture.
Methods: A natural tooth was embedded between vertically-aligned and 17° angulated implants in a polymethyl methacrylate acrylic resin model. Three designs (Group 1: tooth and vertically-aligned implant; Group 2: tooth and 17° angulated implant, Group 3: tooth and vertically-aligned implant having a different prosthetic connection to Group 1) of tooth-implant supported prostheses (n=4) were fabricated.
Purpose: This study investigated the peel strength of two different soft liners to a polymethylmethacrylate (PMMA) denture base resin before and after thermocycling.
Materials And Methods: The silicone-based soft liner materials tested were Molloplast B and Permaflex; the denture base material was a heat-cured acrylic resin, Meliodent. A total of 40 specimens was prepared using rectangular molds with dimensions of 100 x 10 x 2 mm for PMMA and 150 x 10 x 2 mm for soft liners, as described in ASTM-D903-93.
Objective: Some factors such as gender, age, craniofacial morphology, body structure, occlusal contact patterns may affect the maximum bite force. Thus, the purposes of this study were to determine the mean maximum bite force in individuals with normal occlusion, and to examine the effect of gender, facial dimensions, body mass index (BMI), type of functional occlusion (canine guidance and group function occlusion) and balancing side interferences on it.
Material And Methods: Thirty-four individuals aged 19-20 years-old were selected for this study.
Purpose: This study compared shear bond strength and type of bond failure between a highly cross-linked tooth and different denture base polymers.
Materials And Methods: Cross-linked denture teeth were bonded to either a heat-, an auto-, a microwave-polymerized denture base resin or a relatively new injection-molded, microwave-polymerizable polyurethane-based resin. Six experimental groups were established for each of the shear and peel tests.
Purpose: To determine the effect of resin surface treatment with dissolved maleic anhydride in butanone added into primer on the tensile bond strength between an acrylic denture base resin and a silicone soft liner.
Materials And Methods: To test tensile bond strength, standard dumbbell-shaped acrylic specimens were prepared. Five experimental groups, including the control, were tested (n = 5).
Maximum voluntary bite force is an indicator of the functional state of the masticatory system and the level of maximum bite force results from the combined action of the jaw elevator muscles modified by jaw biomechanics and reflex mechanisms. The measurement of bite force can provide useful data for the evaluation of jaw muscle function and activity. It is also an adjunctive value in assessing the performance of dentures.
View Article and Find Full Text PDFObjectives: Microorganisms may colonise polysiloxane soft liners leading to bio-deterioration. The aim of this study was to investigate in vitro adhesion and in vivo biofilm formation of Candida species on polysiloxane surfaces.
Methods: The materials used in this study were Molloplast B, GC Reline soft, Mollosil Plus, Silagum Comfort and Palapress Vario.
This study investigated temperature rises caused by different light curing units (LCUs) in dentin of different thicknesses. The different LCUs tested in this study were namely: quartz-tungsten-halogen (QTH) (Heliolux DLX) LCU, plasma arc (PAC) (Apollo 95E Elite) LCU, and light emitting diode (LED) (Mini LED) in standard curing mode as well as pulse and soft-start modes. One hundred and forty dentin disks of 0.
View Article and Find Full Text PDFAim: The aim of this report is to describe the relationship of some salivary parameters to dental erosion resulting from excessive citric acid consumption and present a description of a prosthetic approach used to restore the damaged dentition of a patient with severe erosion.
Background: The high consumption of dietary sources of acids can lead to erosion or the excessive wear of dental hard tissues. Erosion may be modified by salivary parameters such as flow rate, pH, and buffering capacity.
The influence of three curing modes of a high-powered LED curing unit on temperature rise under 2-mm-thick dentin was investigated during the polymerization of resin composite samples of Admira, Filtek P60, Premise, Tetric Flow, Tetric Ceram, and Filtek Z250. Ninety standard specimens were prepared. The bonding agents and resin composites were cured with standard, pulse, or soft-start mode (n=5 for each curing mode).
View Article and Find Full Text PDFObjective: The aim of the present study was to evaluate the clinical performance of four denture soft liners up to 12 months.
Materials And Methods: Thirty-three edentulous patients who experienced difficulties when using hard denture bases because of changes in denture-supporting tissues were accepted for the study and randomly received Molloplast B, GC Reline Soft, Silagum Comfort, or Mollosil Plus relines. Performance of the materials was evaluated using nine criteria at 3, 6, and 12 months: physical integrity, surface detail, adhesion, color, odor, plaque accumulation, resilience, hygiene, and mucosal condition.
This study investigated the effects of three bleaching agents (Whiteness Perfect, Whiteness Super, and Whiteness HP) on the color change and refractive index of three dental composites (Admira, Durafill VS, and Gradia Direct). Twenty disk-shaped specimens (10 x 2 mm) of each composite were prepared and divided into four subgroups (n=5). An unbleached group was used as a control, while the remaining specimens in the three subgroups were bleached with one of the bleaching agents respectively.
View Article and Find Full Text PDFThis study examined the surface microhardness of four kinds of resin composites with different fillers and resin matrices. Ten specimens of 2 mm thickness and 4 mm diameter of each resin composite were polymerized using a halogen light, a blue light-emitted diode, and a plasma arc unit. Microhardness evaluation was performed at top and bottom surfaces for each specimen using a Vickers microhardness tester.
View Article and Find Full Text PDFThis study was performed to determine whether some flexural properties of a denture base resin material could be improved through reinforcement with five types of aesthetic fibers at 3% concentration by weight and in 2, 4, and 6 mm length. Five specimens of similar dimensions were prepared for each of the test groups; base resin and the same resin with glass, rayon, polyester, nylon 6 and nylon 6,6 fibers in three different lengths. Flexural properties were evaluated by using a 3-point bending test.
View Article and Find Full Text PDFWith a view to understanding the structure-property relation of a silicone-based soft lining denture material after polymerization, its chemical composition and viscoelastic properties were investigated. Chemical compositions of the cured and uncured polymers of a commercial silicone permanent soft liner were determined by infrared spectroscopic analysis, nuclear magnetic resonance (NMR), and X-ray photoelectron spectroscopy. Dynamic mechanical analysis (DMA) method was used to investigate the viscoelastic behavior of the cured polymer of liner.
View Article and Find Full Text PDFThis study was conducted to observe the changes in impact resistance of a denture base resin reinforced with five types of fiber. E-glass, polyester, rayon, nylon 6, and nylon 6/6 fibers were cut into 2, 4, and 6 mm lengths and added into the resin at a concentration of 3% by weight. Five test specimens for each formulation, as well as control specimens without fiber, were prepared using a mold including a V-shaped notch with 55 x 10 x10 mm dimensions.
View Article and Find Full Text PDF