Purpose: To determine the physical compatibility of 10% calcium chloride and 10% calcium gluconate in combination with injectable solutions, administered in the paediatric and adult intensive care unit setting during toxicological resuscitation involving calcium channel blockers and beta-blockers.
Methods: Forty-eight combinations were prepared at room temperature, including the following products: calcium chloride, calcium gluconate, insulin, epinephrine, norepinephrine, highly concentrated dextrose solution, sodium chloride, Plasma-Lyte A and Ringer's lactate. A visual evaluation at times 0, 1, 4, 24, 48 and 72 hours and a particle count test with the LS-20 particle counter at times 0, 4, 24 and 72 hours were performed.