Photon counting CT was recently introduced into clinical practice [Rajendran K, Petersilka M, Henning A, Shanblatt ER, Schmidt B, Flohr TG, Ferrero A, Baffour F, Diehn FE, Yu L, Rajiah P, Fletcher JG, Leng S, McCollough CH. First Clinical Photon-counting Detector CT System: Technical Evaluation. Radiology 2022;303(1):130-138.
View Article and Find Full Text PDFRadiol Clin North Am
November 2023
Optimization of dual-energy CT (DECT) workflow is critical for successful integration of DECT into practice. Patient selection strategies differ by scanner type and may be based on patient size, exam indication, or both. All stakeholders involved in patient scheduling and scan acquisition should be involved in patient triage to DECT.
View Article and Find Full Text PDFPurpose: Computed tomography (CT) coronary angiography performed on a detector-based spectral scanner helps more closely approximate severity of stenosis with nuclear medicine and cardiac catheterization tests compared with single-energy CT (SECT) in patients with an original CAD-RADS score of 3 and higher.
Methods: This retrospective trial was conducted between January 2017 and December 2019 and included 52 patients with a CAD-RADS score of 3 and higher. Two reading sessions were performed 6 weeks apart.
Dual-energy CT is an emerging technology which is progressively becoming more available for routine clinical applications. As practices and institutions evaluate the business case for purchase of these high-end scanners, the clinical utility and downstream costs must be determined. This article will provide an overview of the technology and will review direct and indirect costs associated with the implementation of dual-energy CT programs.
View Article and Find Full Text PDFBackground: Dual-energy CT image sets have many applications in abdominopelvic imaging but no demonstrated clinical effect.
Purpose: To determine the effect of dual-energy CT iodine maps on abdominopelvic imaging follow-up recommendation rates.
Materials And Methods: Retrospective study of abdominopelvic CTs acquired from April 2017 through June 2018.
Purpose: To determine the feasibility of performing dual-energy CT with a single-source spectral detector system in obese patients.
Materials And Methods: Retrospective, IRB-approved review of 28 patients weighing ≥ 270 lbs (122 kg) who underwent CT of the abdomen on a single-source spectral detector system was performed. Two blinded, independent radiologists rated relative preference between conventional CT images taken at 120 kVp (CCT120) and monoenergetic 70 keV equivalent (MonoE70) as well as iodine map image quality in the spleen, pancreas, kidneys, and liver.
J Reconstr Microsurg
May 2018
Background: Variations in anterolateral thigh (ALT) arterial anatomy are well documented. Ethnicity is a known risk factor for vascular variation in several organ systems, but its impact on ALT anatomy has not been studied. Anecdotally, we observed frequent ALT arterial variation in African American (AA) patients.
View Article and Find Full Text PDF