Aims: Guidelines recommend insertable cardiac monitor (ICM) in the early phases of the evaluation of unexplained syncope (US) syncope, when an arrhythmic etiology is suspected. We examined the diagnostic yield of the last generation ICM (LG-ICM) to establish the causes of US, by assessing in the clinical practice the incidence of: relevant arrhythmia diagnosis, syncope recurrences and CM-guided cardiac electronic device (CIED) implantation. We investigated also baseline patient characteristics associated to an increased risk of relevant arrhythmias and of syncope recurrence.

View Article and Find Full Text PDF

Blood volume analysis provides a quantitative volume assessment in patients with equivocal or discordant clinical findings. Reports on its use in mechanical circulatory support are limited and it has never been described in patients with a total artificial heart. Our series demonstrates that patients supported with total artificial heart as a bridge to transplant have significant reductions in red blood cell volume and heterogeneous adaptations in their total blood volume and plasma volume.

View Article and Find Full Text PDF

To address the unmet clinical need for pediatric circulatory support, we are developing an operationally versatile, hybrid, continuous-flow, total artificial heart ("Dragon Heart"). This device integrates a magnetically levitated axial and centrifugal blood pump. Here, we utilized a validated axial flow pump, and we focused on the development of the centrifugal pump.

View Article and Find Full Text PDF

The total artificial heart (TAH) has a long and rich history, being the product of decades of innovation, hard work, and dedication. This review examines the history of the TAH, a device that has revolutionized the treatment of end-stage biventricular heart failure. It reviews the development of the device from early concepts to the current state-of-the-art device, the SynCardia TAH, which has been implanted in over 2,000 patients worldwide.

View Article and Find Full Text PDF

The incidence and prevalence of end-stage heart failure continue to rise; however, the number of donor hearts available for transplantation continues to be limited. Therefore, alternatives to transplantation, such as the use of total artificial hearts (TAH), are necessary. The long and winding road to the development and implantation of the ideal TAH remains under construction.

View Article and Find Full Text PDF

Background: We sought to compare heart transplant (HTX) outcomes from patients with a total artificial heart (TAH), biventricular assist device (BiVAD), or left ventricular assist device (LVAD) as a bridge to transplant (BTT). Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS)-Scientific Registry of Transplant Recipients (SRTR) created a dataset with TAH or durable mechanical circulatory support (MCS) who reached HTX between 2006 and 2015.

Methods: The retrospective analysis compared TAH outcomes with those with a BiVAD or LVAD before HTX.

View Article and Find Full Text PDF

Total artificial hearts (TAH) are used in patients with end-stage heart failure as a bridge-to-transplant. AKI is a common postoperative complication associated with TAH implant. Patients requiring temporary dialysis are denied implantation of TAH due to the inability to provide outpatient (OP) dialysis in the long term.

View Article and Find Full Text PDF

Background: The SynCardia temporary total artificial heart (TAH-t) is an effective bridge to transplantation for patients with severe biventricular failure. However, granular single-center data from high-volume centers are lacking. We report our experience with the first 100 TAH-t recipients.

View Article and Find Full Text PDF

Objectives: To evaluate whether mediastinitis/deep sternal wound infection (Med/DSWI) is more common in ventricular assist device (VAD) with delayed sternal closure (DSC) compared to VAD with primary sternal closure (PSC).

Methods: A literature search was done over the last four decades for studies that addressed this comparison.

Results: Two studies met our inclusion criteria, and their results are contradictory.

View Article and Find Full Text PDF

Background: Whether prone position (PP) improves clinical outcomes in COVID-19 pneumonia treated with noninvasive ventilation (NIV) is unknown. We evaluated the effect of early PP on 28-day NIV failure, intubation and death in noninvasively ventilated patients with moderate-to-severe acute hypoxemic respiratory failure due to COVID-19 pneumonia and explored physiological mechanisms underlying treatment response.

Methods: In this controlled non-randomized trial, 81 consecutive prospectively enrolled patients with COVID-19 pneumonia and moderate-to-severe (paO2/FiO2 ratio < 200) acute hypoxemic respiratory failure treated with early PP + NIV during Dec 2020-May 2021were compared with 162 consecutive patients with COVID-19 pneumonia matched for age, mortality risk, severity of illness and paO2/FiO2 ratio at admission, treated with conventional (supine) NIV during Apr 2020-Dec 2020 at HUMANITAS Gradenigo Subintensive Care Unit, after propensity score adjustment for multiple baseline and treatment-related variables to limit confounding.

View Article and Find Full Text PDF

The SynCardia Total Artificial Heart (TAH, SynCardia Systems, Tucson, AZ) is the only biventricular cardiac replacement approved for bridge to transplantation by the U.S. Food and Drug Administration (FDA) and which carries the European Union CE mark.

View Article and Find Full Text PDF

Introduction: Fifteen to twenty percent of the patients with complete hydatidiform mole transform malignancy into gestational trophoblastic tumors. The marked proliferation of trophoblastic cells is one of the characteristics that determines high risk for the occurrence of post-hydatidiform mole malignancy. The objective of the study was to analyze the histopathologic feature of the marked proliferation of trophoblastic cells as a role in post-hydatidiform mole malignancy that can be used as a determinant of the risk of malignancy post-hydatidiform mole.

View Article and Find Full Text PDF

Aim: The benefit of cardiac pacing in patients with severe recurrent reflex syncope and asystole induced by tilt testing has not been established. The usefulness of tilt-table test to select candidates for cardiac pacing is controversial.

Methods And Results: We randomly assigned patients aged 40 years or older who had at least two episodes of unpredictable severe reflex syncope during the last year and a tilt-induced syncope with an asystolic pause longer than 3 s, to receive either an active (pacing ON; 63 patients) or an inactive (pacing OFF; 64 patients) dual-chamber pacemaker with closed loop stimulation (CLS).

View Article and Find Full Text PDF

The total artificial heart (TAH) is a device that replaces the failing ventricles. There have been numerous TAHs designed over the last few decades, but the one with the largest patient experience is the SynCardia temporary TAH. The 50-mL and 70-mL sizes have been approved in the United States, Europe, and Canada as a bridge to transplantation.

View Article and Find Full Text PDF

Heart failure is a complex, growing problem with significant morbidity and mortality. Though heart transplantation remains the gold standard treatment for end-stage heart failure, there remains a national shortage of donor hearts. Mechanical circulatory support has provided an additional option for clinicians to support patients for the purposes of bridging patients to transplantation or to be used for destination therapy purposes.

View Article and Find Full Text PDF

Patients on mechanical circulatory support (MCS) devices are placed on aspirin and may require platelet function testing (PFT) to monitor the adequacy of therapy. Routine laboratory PFT is performed using whole blood aggregation (WBA) which typically has a long turnaround time (4-5 hours) and may not be readily available. By contrast, platelet mapping by thromboelastography (TPM) can provide results within 45 minutes.

View Article and Find Full Text PDF

Background And Purpose: Mechanical circulatory support (MCS) devices are commonly used in heart failure patients. These devices carry risk for presumably embolic and additionally hemorrhagic stroke. Alterations in blood flow play a key role in stroke pathophysiology, and we aimed to learn more about hemodynamic compromise.