Objectives: A recent European randomized trial - Tracheal Occlusion To Accelerate Lung Growth - demonstrated that fetoscopic endoluminal tracheal occlusion (FETO) is associated with increased postnatal survival among infants with severe congenital diaphragmatic hernia (CDH). However, this differs in middle-income countries such as Brazil, where abortion is illegal and neonatal intensive care is inadequate. This study evaluated the effects of FETO on improving the survival of infants with moderate-to-severe CDH in isolated and non-isolated cases.
View Article and Find Full Text PDFImprovements in fetal ultrasound have allowed for the diagnosis and treatment of fetal diseases in the uterus, often through surgery. However, little attention has been drawn to the assessment of fetal pain. To address this gap, a fetal pain scoring system, known as the Fetal-7 scale, was developed.
View Article and Find Full Text PDFObjectives: Open spina bifida (OSB) is the most common neural tube defect. Prenatal repair reduces the need for ventriculoperitoneal shunting (VPS) due to hydrocephalus from 80-90% to 40-50%. We aimed to determine which variables work as risk factors for VPS at 12 months of age in our population.
View Article and Find Full Text PDFPurpose: Myelomeningocele (MMC) is an open neural tube defect that causes great morbidity. Prenatal open repair is the standard treatment; however, there are many complications related to the procedure. This study reports preliminary findings of open in utero repair of MMC in a public tertiary hospital in Brazil and describes factors that could be associated with increased surgical morbidity.
View Article and Find Full Text PDFIntroduction: The question of whether the human fetus experiences pain has received substantial attention in recent times. With the advent of high-definition 4-dimensional ultrasound (4D-US), it is possible to record fetal body and facial expressions.
Objective: To determine whether human fetuses demonstrate discriminative acute behavioral responses to nociceptive input.
Objectives:: Quantitative fluorescence polymerase chain reaction (QF-PCR) is a rapid and reliable method for screening aneuploidies, but in Brazil, it is not used in public services. We investigated the accuracy of QF-PCR for the prenatal recognition of common aneuploidies and compared these results with cytogenetic results in our laboratory.
Method:: A ChromoQuant QF-PCR kit containing 24 primer pairs targeting loci on chromosomes 21, 13, 18, X and Y was employed to identify aneuploidies of the referred chromosomes.