Publications by authors named "Antonio Arribas"

Objective: To evaluate the impact of learning on outcome with use of two different left atrial appendage (LAA) occlusion devices.

Background: Two self-expanding devices, the Watchman and the Amplatzer Cardiac Plug (ACP), have been used for LAA occlusion in the last few years. It has been demonstrated that complications associated with implantation decrease in frequency with operator experience.

View Article and Find Full Text PDF

Objective: Clinical outcomes of patients undergoing aortic valve replacement may be influenced by the presence of residual gradients and patient-prosthesis mismatch. The aim of this study was to compare hemodynamic performance and clinical outcomes at 5 years after prospectively randomized porcine versus bovine aortic valve replacement. We also aimed to determine the effects of valve hemodynamics on left ventricular (LV) mass regression.

View Article and Find Full Text PDF

This study compares the implantation characteristics and the hemodynamic performance of the new Carpentier-Edwards Perimount Magna (CEPM) xenograft with those of the standard Perimount (CEPS) valve in the aortic position. Eighty consecutive patients surviving an aortic valve replacement with either the CEPS valve (n=40) or the CEPM prosthesis (n=40) in the supra-annular position were retrospectively reviewed. One year follow-up was complete and hemodynamic performance assessed by Doppler echocardiography.

View Article and Find Full Text PDF

We compared the hemodynamic performance of the Edwards Perimount Magna (EPM) and the Medtronic Mosaic (MM) bioprostheses according to the patient aortic annulus diameter (AAD). Eighty-six patients undergoing aortic valve replacement were prospectively assigned to receive either an EPM-valve (n=43) or an MM-bioprosthesis (n=43). Randomization was performed after measuring the AAD and patients were grouped according to their AAD: <22 mm (n=12), 22-23 mm (n=31) and >23 mm (n=43).

View Article and Find Full Text PDF

C-reactive protein (CRP) is a marker of inflammation and predicts outcome in apparently healthy subjects and patients with coronary artery disease. Systemic inflammation is present in patients with aortic valve stenosis (AS). The aim of this prospective study was to assess whether CRP levels predict the progression of AS severity.

View Article and Find Full Text PDF

We report a woman with a VVI pacemaker and a history of stroke and severe hypoxemia due to a right-to-left shunt. Anomalous blood flow was through a patent foramen oval, and was related directly with severe tricuspid regurgitation because the ventricular pacemaker electro de was adhered to the tricuspid valve. She was treated successfully with surgery.

View Article and Find Full Text PDF

Introduction And Objectives: Troponin I (TnI) is a useful marker of myocardial damage for the diagnosis and prognosis of acute coronary syndrome. The purpose of this study was to analyze the long-term prognostic value of the peak TnI concentration obtained within 48 h of admission to the coronary unit for unstable angina.

Methods: The study included 149 consecutive patients.

View Article and Find Full Text PDF

Introduction And Objectives: Although atrial pacing is a more physiological mode of stimulation in sinus node dysfunction, the pacing modes most often are used DDD and VVI. The aim of our study was to demonstrate that AAI/AAIR pacing is effective and safe by analyzing the complications and mortality of this pacing mode in a long-term follow-up study.

Patients And Method: Between 1982 and 2000 definitive AAI-mode pacemakers were implanted for sinus node dysfunction in mode AAI in 160 patients.

View Article and Find Full Text PDF