Publications by authors named "Anton Petrich"

Purpose: The aim of this study was to assess Candida albicans attachment on conventionally fabricated (polymethylmethacrylate, PMMA), CAD-CAM milled, and 3D-printed acrylic resin bases pre- and post-simulated thermal aging, along with examining material surface changes after aging.

Materials And Methods: Forty-six samples (10 mm × 10 mm × 2 mm) for each of four material groups (conventional heat-polymerized PMMA, CAD-CAM milled acrylic resin base, CAD-CAM 3D-printed methacrylate resin base, CAD-CAM 3D-printed urethane methacrylate resin base) were subjected to 0, 1, or 2 years of simulated thermal aging. Microscopic images were taken before and after aging, and C.

View Article and Find Full Text PDF

Purpose: To compare retentive forces of removable partial denture clasps traditionally fabricated with cobalt-chromium (CoCr) material and two computer-aided design and computer-aided manufactured (CAD/CAM) thermoplastic polymers.

Materials And Methods: Forty-eight clasp assemblies (16 CoCr, 16 polyetheretherketone (PEEK) and 16 polyetherketoneketone (PEKK) thermoplastic polymer) were fabricated for 48 mandibular tooth analogs. Individual clasps were inserted and removed on the tooth analogs utilizing a chewing simulator for 15,000 cycles to simulate 10 years of use.

View Article and Find Full Text PDF

Purpose: The purpose of this in vitro study was to evaluate the effect of software on scan time, trueness, and precision of digital scans created using the CEREC Omnicam.

Material And Methods: Sixty scans (20 scans/provider) of a standard reference cast were made by three different providers using the CEREC Omnicam with both CEREC Ortho 1.2.

View Article and Find Full Text PDF

Purpose: To compare the reverse torque values (RTVs) of abutment screws tightened from three different angles.

Materials And Methods: Implant abutment screws (n = 48), abutments (3), and regular platform implant analogs (3) were divided into three angulation groups (n = 16/group). Custom guides of 0°, 10°, and 20° were fabricated to verify driver angulation.

View Article and Find Full Text PDF

The method of fabricating an auricular prosthesis by digitally positioning a mirror image of the soft tissue, then designing and using rapid prototyping to produce the mold, can reduce the steps and time needed to create a prosthesis by the traditional approach of sculpting either wax or clay. The purpose of this clinical report is to illustrate how the use of 3-dimensional (3-D) photography, computer technology, and additive manufacturing can extensively reduce many of the preliminary procedures currently used to create an auricular prosthesis.

View Article and Find Full Text PDF