Objective: To provide an update on Australian persistent pain services (number, structure, funding, wait times, activity).
Methods: An updated national search was conducted. Of those identified, 74 persistent pain services provided detailed responses between July 2016 and February 2018 (64 adult, seven pediatric, two pelvic pain, and one cancer pain).
Microfluidic devices allow for the manipulation of fluids, particles, cells, micro-sized organs or organisms in channels ranging from the nano to submillimeter scales. A rapid increase in the use of this technology in the biological sciences has prompted a need for methods that are accessible to a wide range of research groups. Current fabrication standards, such as PDMS bonding, require expensive and time consuming lithographic and bonding techniques.
View Article and Find Full Text PDFPurpose: The goal of this work was to develop and test a cylindrical tissue-equivalent quality assurance (QA) phantom for micro computed tomography (microCT) image-guided small animal irradiators that overcomes deficiencies of existing phantoms due to its mouse-like dimensions and composition.
Methods: The 8.6-cm-long and 2.
The oxygen status of a tumor has significant clinical implications for treatment prognosis, with well-oxygenated subvolumes responding markedly better to radiotherapy than poorly supplied regions. Oxygen is essential for tumor growth, yet estimation of local oxygen distribution can be difficult to ascertain in situ, due to chaotic patterns of vasculature. It is possible to avoid this confounding influence by using avascular tumor models, such as tumor spheroids, a much better approximation of realistic tumor dynamics than monolayers, where oxygen supply can be described by diffusion alone.
View Article and Find Full Text PDFA simple method of simulating possible coded aperture phase contrast X-ray imaging apparatus is presented. The method is based on ray tracing, with the rays treated ballistically within a voxelized sample and with the phase-shift-induced angular deviations and absorptions applied at a plane in the middle of the sample. For the particular case of a coded aperture phase contrast configuration suitable for small animal pre-clinical imaging we present results obtained using a high resolution voxel array representation of a mathematically-defined 'digital' mouse.
View Article and Find Full Text PDFPurpose: To evaluate a novel respiratory motion compensation strategy combining gated beam delivery with the mean target position (MTP) concept for pulmonary stereotactic body radiotherapy (SBRT).
Materials And Methods: Four motion compensation strategies were compared for 10 targets with motion amplitudes between 6mm and 31mm: the internal target volume concept (plan(ITV)); the MTP concept where safety margins were adapted based on 4D dose accumulation (plan(MTP)); gated beam delivery without margins for motion compensation (plan(gated)); a novel approach combining gating and the MTP concept (plan(gated&MTP)).
Results: For 5/10 targets with an average motion amplitude of 9mm, the differences in the mean lung dose (MLD) between plan(gated) and plan(MTP) were <10%.
Background And Purpose: Computer controlled breath-hold effectively reduces organ motion for image-guided precision radiotherapy of lung tumors. However, the acquisition time of 3D cone-beam-CT (CBCT) exceeds maximum breath-hold times. We have developed an approach enabling online verification using CBCT image acquisition with ABC®-based breath-hold.
View Article and Find Full Text PDFIntroduction: One method to overcome the problem of lung tumour movement in patients treated with radiotherapy is to restrict tumour motion with an active breathing control (ABC) device. This study evaluated the feasibility of using ABC in patients receiving radical radiotherapy for non-small cell lung cancer.
Methods: Eighteen patients, median (range) age of 66 (44-82) years, consented to the study.
A technique is presented to allow a breathing pattern to be obtained from any multi-slice CT, cone-beam or other series of sequential chest x-ray image sets. The technique requires no extra signals to be recorded and does not need specific external or internal oscillating structures to be visible in the field of view. The breathing pattern is instead acquired from analysing the variation in pixel values between projection images.
View Article and Find Full Text PDFWe describe a novel, typically prokaryotic, sensor kinase in chloroplasts of green plants. The gene for this chloroplast sensor kinase (CSK) is found in cyanobacteria, prokaryotes from which chloroplasts evolved. The CSK gene has moved, during evolution, from the ancestral chloroplast to the nuclear genomes of eukaryotic algae and green plants.
View Article and Find Full Text PDFResonant strengths have been measured for dielectronic recombination of Li-like iodine, holmium, and bismuth using an electron beam ion trap. By observing the atomic number dependence of the state-resolved resonant strength, clear experimental evidence has been obtained that the importance of the generalized Breit interaction (GBI) effect on dielectronic recombination increases as the atomic number increases. In particular, it has been shown that the GBI effect is exceptionally strong for the recombination through the resonant state [1s2s(2)2p(1/2)](1).
View Article and Find Full Text PDF