Ion mobility mass spectrometry (IM-MS) measures the mass, size, and shape of ions in the same experiment, and structural information is provided via collision cross-section (CCS) values. The majority of commercially available IM-MS instrumentation relies on the use of CCS calibrants, and here, we present data from a family of poly(l-lysine) dendrimers and explore their suitability for this purpose. In order to test these compounds, we employed three different IM-MS platforms (Agilent 6560 IM-QToF, Waters Synapt G2, and a home-built variable temperature drift tube IM-MS) and used them to investigate six different generations of dendrimers in two buffer gases (helium and nitrogen).
View Article and Find Full Text PDFUnderstanding modification of synthetic polymer structures is necessary for their accurate synthesis and potential applications. In this contribution, a series of partially hydrolyzed poly(2-oxazoline) species were produced forming poly[(2-polyoxazoline)--(ethylenimine)] (P(EtOx--EI)) copolymers; EI being the hydrolyzed product of Ox. Bulk mass spectrometry (MS) measurements accurately measured the EI content.
View Article and Find Full Text PDFDue to the natural dispersity that is present in synthetic polymers, an added complexity is always present in the analysis of polymeric species. Tandem mass spectrometry analysis requires the isolation of individual precursors before a fragmentation event to allow the unambiguous characterization of these species and is not viable at certain levels of complexity due to achievable isolation widths. Two-dimensional mass spectrometry (2DMS) fragments ions and correlates fragments with their corresponding precursors without the need for isolation.
View Article and Find Full Text PDFThe structure and sequence elucidation of complex homo- and copolymers is key for further understanding polymers, polymer synthesis, and polymer interactions in biological processes. In this contribution, poly(dimethylacrylamide) homo- and dimethylacrylamide/4-acryloylmorpholine block copolymers were synthesized and analyzed by electron capture dissociation (ECD) and Fourier transform ion cyclotron resonance (FT-ICR) tandem mass spectrometry. Double-resonance experiments were carried out, providing a better understanding of the fragmentation process.
View Article and Find Full Text PDFWith increasing focus on the structural elucidation of polymers, advanced tandem mass spectrometry techniques will play a crucial role in the characterization of these compounds. In this contribution, synthesis and analysis of methyl-initiated and xanthate-terminated poly(2-ethyl-2-oxazoline) using Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) was achieved. Electron capture dissociation (ECD) produced full end group characterization as well as backbone fragmentation including complete sequence coverage of the polymer.
View Article and Find Full Text PDFRationale: Tandem mass spectrometry of phosphorylated ions can often yield a limited number of product ions owing to the labile nature of phosphate groups. Developing techniques to improve dissociation for this type of ion has implications for the structural characterisation of many different phosphorylated ions, such as those from nucleotides, pharmaceutical compounds, peptides and polymers.
Methods: Solutions of adenosine monophosphate, diphosphate and triphosphate (AMP, ADP and ATP) were studied in a hybrid linear ion trap-Fourier transform ion cyclotron resonance (FTICR) mass spectrometer.
The quantification of genotoxic impurities (GIs) such as hydrazine (HZ) is of critical importance in the pharmaceutical industry in order to uphold drug safety. HZ is a particularly intractable GI and its detection represents a significant technical challenge. Here, we present, for the first time, the use of electrochemical analysis to achieve the required detection limits by the pharmaceutical industry for the detection of HZ in the presence of a large excess of a common active pharmaceutical ingredient (API), acetaminophen (ACM) which itself is redox active, typical of many APIs.
View Article and Find Full Text PDFThe collisionally activated dissociation (CAD) and electron capture dissociation (ECD) of doubly charged tocopheryl polyethylene glycol succinate (TPGS) have been examined. Li(+), Na(+), K(+), Ag(+), and H(+) were selected in the study, and the competitive influence of each ion was investigated by fragmenting TPGS attached with two different cations, [M + X1 + X2](2+) (X1 and X2 refer to Li(+), Na(+), K(+), Ag(+), H(+)). For metallic adducts, CAD results show that the dissociation of ionic adducts from the precursor is most likely depending on the binding strength, where the affinity of each ion to the TPGS is in the order of Ag(+) ≈ Li(+) ˃ Na(+) ˃ K(+).
View Article and Find Full Text PDFD-α-tocopheryl polyethylene glycol 1000 succinate (TPGS) is an important polymeric excipient frequently used in drug formulation. However, differing compositions of the TPGS samples between batches are believed to result in variable performance of the formulated product. Herein, a high performance method using Fourier-transform ion cyclotron resonance (FTICR) mass spectrometry (MS) and tandem mass spectrometry (MS/MS) to analyze the composition of TPGS samples and the structure of TPGS was established.
View Article and Find Full Text PDFThe incorporation of a chip-based high field asymmetric waveform ion mobility spectrometry (FAIMS) separation in the ultra (high)-performance liquid chromatography-high resolution mass spectrometry (UHPLC-HRMS) determination of the (R/S) ibuprofen 1-β-O-acyl glucuronide metabolite in urine is reported. UHPLC-FAIMS-HRMS reduced matrix chemical noise, improved the limit of quantitation approximately two-fold and increased the linear dynamic range compared to the determination of the metabolite without FAIMS separation. A quantitative evaluation of the prototype UHPLC-FAIMS-HRMS system showed better reproducibility for the drug metabolite (%RSD 2.
View Article and Find Full Text PDFTwo polymeric excipients, typically used in enabling drug delivery approaches, are Gelucire 44/14 (a product of Gattefosse s.a, St Priest, France) and polysorbate 80; these are known to improve solubility of poorly water-soluble drugs and, hence, increase their effective bioavailability. In addition to the use of Gelucire 44/14 and polysorbate 80 as excipients in drugs, they are also widely used as cosmetic and food additives.
View Article and Find Full Text PDFMiniaturized ultra high field asymmetric waveform ion mobility spectrometry (FAIMS) is used for the selective transmission of differential mobility-selected ions prior to in-source collision-induced dissociation (CID) and time-of-flight mass spectrometry (TOFMS) analysis. The FAIMS-in-source collision induced dissociation-TOFMS (FISCID-MS) method requires only minor modification of the ion source region of the mass spectrometer and is shown to significantly enhance analyte detection in complex mixtures. Improved mass measurement accuracy and simplified product ion mass spectra were observed following FAIMS preselection and subsequent in-source CID of ions derived from pharmaceutical excipients, sufficiently close in m/z (17.
View Article and Find Full Text PDFLC ESI FTICR MS of a sample of cediranib identified this pharmaceutical target molecule plus an additional 10 compounds of interest, all of which were less than 10% total ion current (TIC) peak intensity relative to cediranib. LC FTICR tandem mass spectrometry using electron induced dissociation (EID) has been achieved and has proven to be the best way to generate useful product ion information for all of these singly protonated molecules. Cediranib [M + H](+) fragmented by EID to give 29 product ions whereas QTOF-CID generated only one very intense product ion, and linear ion trap-CID, which generated 10 product ions, but all with poor S/N.
View Article and Find Full Text PDFCollision-induced dissociation (CID) and electron-induced dissociation (EID) have been investigated for a selection of small, singly charged organic molecules of pharmaceutical interest. Comparison of these techniques has shown that EID carried out on an FTICR MS and CID performed on a linear ion trap MS produce complementary data. In a study of 33 molecule-cations, EID generated over 300 product ions compared to 190 product ions by CID with an average of only 3 product ions per precursor ion common to both tandem MS techniques.
View Article and Find Full Text PDFThe potential of ion mobility (IM) spectrometry in combination with mass spectrometry (MS) for real-time reaction monitoring is reported. The combined IM-MS approach using electrospray ionization affords gas-phase analyte characterization based on both mass-to-charge (m/z) ratio and gas-phase ion mobility (drift time). The use of IM-MS analysis is demonstrated for the monitoring of the reaction products formed when 7-fluoro-6-hydroxy-2-methylindole is deprotonated by aqueous sodium hydroxide.
View Article and Find Full Text PDFThe direct analysis of pharmaceutical formulations and active ingredients from non-bonded reversed-phase thin layer chromatography (RP-TLC) plates by desorption electrospray ionisation (DESI) combined with ion mobility mass spectrometry (IM-MS) is reported. The analysis of formulations containing analgesic (paracetamol), decongestant (ephedrine), opiate (codeine) and stimulant (caffeine) active pharmaceutical ingredients is described, with and without chromatographic development to separate the active ingredients from the excipient formulation. Selectivity was enhanced by combining ion mobility and mass spectrometry to characterise the desorbed gas-phase analyte ions on the basis of mass-to-charge ratio (m/z) and gas-phase ion mobility (drift time).
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
August 2008
The potential of drift tube ion mobility (IM) spectrometry in combination with high performance liquid chromatography (LC) and mass spectrometry (MS) for the metabonomic analysis of rat urine is reported. The combined LC-IM-MS approach using quadrupole/time-of-flight mass spectrometry with electrospray ionisation, uses gas-phase analyte characterisation based on both mass-to-charge (m/z) ratio and relative gas-phase mobility (drift time) following LC separation. The technique allowed the acquisition of nested data sets, with mass spectra acquired at regular intervals (65 micros) during each IMS separation (approximately 13 ms) and several IMS spectra acquired during the elution of a single LC peak, without increasing the overall analysis time compared to LC-MS.
View Article and Find Full Text PDFMass Spectrom Rev
February 2006
The application of accurate mass measurement for the determination of elemental formula has its origin in the 1950s and for many years was only carried out using magnetic sector mass spectrometers. The availability of such measurements was limited due to the cost and complexity of the instrumentation and the need for considerable expertise to acquire and interpret the spectra. In recent years the incredible pace of instrumental development has changed this, particularly with the renaissance of time of flight mass spectrometry.
View Article and Find Full Text PDFThe results of the comparison of product-ion tandem mass (MS/MS) spectra recorded on three ion trap mass spectrometers, a triple quadrupole mass spectrometer and a Fourier transform ion cyclotron resonance mass spectrometer are reported. The spectra were recorded in accordance with a simple experimental protocol, which involved the collision-induced dissociation (CID) attenuation of the abundance of the [M+H]+ ion to between 10 and 50% of its original abundance. The degree of similarity between the spectra from four of the mass spectrometers was calculated off-line by comparing the five most abundant ions from the spectrum on each instrument.
View Article and Find Full Text PDFJ Am Soc Mass Spectrom
October 2003
The results from an intercomparison of accurate mass measurement of a small molecule (molecular weight 475 Da) across a broad range of mass spectrometers are reported. The intercomparison was designed to evaluate the relative capabilities and the optimum methodology of the diverse range of mass spectrometers currently used to record accurate mass measurements. The data will be used as a basis for developing guidance on accurate mass measurement.
View Article and Find Full Text PDFMass spectral libraries provide a tool for identifying unknown compounds using both molecular weight and fragmentation information. Mass spectrometers with electrospray ionisation (ESI) and atmospheric chemical ionisation (ApCI) sources have the capability to produce data of this type using in-source collisionally induced dissociation (CID), and in-source CID libraries can be created. Due to the variation in electrospray source design from different instrument manufacturers, the production of reproducible in-source CID spectra that can be used in libraries for all instrument types is not a trivial task.
View Article and Find Full Text PDF