Introduction: Hemolysis of blood samples creates significant delays in the treatment and disposition of patients in the emergency department. The purpose of this study was to compare the hemolysis rates of coagulation blood samples obtained during insertion of an intravenous (IV) catheter without (group 1) or with (group 2) extension tubing connected to the IV catheter hub. A secondary purpose of this study was to determine whether the investigators could predict whether a coagulation sample was hemolyzed based on visual observation during the specimen withdrawal process.