Introduction: Increased evaporative water loss (EWL) in burn patients leads to dehydration and hypothermia. Early clinical studies performed with outdated hygrometers suggested a 17 to 75 times increased EWL in burns with contradicting results for the different burn depths.Our study proposals were: (1) obtain reliable data of the EWL of all burn depths, (2) compare these results with findings from earlier studies, (3) evaluate the usefulness of the EWL in differentiating between superficial and deep partial thickness burns, (4) determine the effect of Biobrane on the EWL of superficial partial thickness burns in vivo, and (5) evaluate the effect of the sterile incision foil Opraflex on the EWL in split skin graft donor sites.