Objective: [ 18 F]FE-PE2I (FE-PE2I) is a new radiotracer for dopamine transporter (DAT) imaging with PET. The aim of this study was to evaluate the visual interpretation of FE-PE2I images for the diagnosis of idiopathic Parkinsonian syndrome (IPS). The inter-rater variability, sensitivity, specificity, and diagnostic accuracy for visual interpretation of striatal FE-PE2I compared to [ 123 I]FP-CIT (FP-CIT) single-photon emission computed tomography (SPECT) was evaluated.
View Article and Find Full Text PDFObjective: To investigate the potential impact of polymorphism in the 3'-untranslated region (3'UTR) of the SLC6A3 gene (DAT1) on normal variation in dopamine transporter (DAT) imaging with [18F]FE-PE2I PET and [123I]FP-Cit SPECT.
Methods: Thirty-six individuals (mean age 70.4±5.
Background: Attenuation correction of PET/MRI is a remaining problem for whole-body PET/MRI. The statistical decomposition algorithm (SDA) is a probabilistic atlas-based method that calculates synthetic CTs from T2-weighted MRI scans. In this study, we evaluated the application of SDA for attenuation correction of PET images in the pelvic region.
View Article and Find Full Text PDFBackground: Dopamine transporter (DAT) imaging may be of diagnostic value in patients with clinically suspected parkinsonian disease. The purpose of this study was to compare the diagnostic performance of DAT imaging with positron emission computed tomography (PET), using the recently developed, highly DAT-selective radiopharmaceutical [F]FE-PE2I (FE-PE2I), to the commercially available and frequently used method with [I]FP-CIT (FP-CIT) single-photon emission computed tomography (SPECT) in early-stage idiopathic parkinsonian syndrome (PS).
Methods: Twenty-two patients with a clinical de novo diagnosis of PS and 28 healthy controls (HC) participating in an on-going clinical trial of FE-PE2I were analyzed in this study.
F-()--(3-iodoprop-2-enyl)-2β-carbofluoroethoxy-3β-(4'-methyl-phenyl) nortropane (F-FE-PE2I) was recently developed and has shown adequate affinity and high selectivity for the dopamine transporter (DAT). Previous studies have shown promising results for F-FE-PE2I as a suitable radioligand for DAT imaging. In this study, we investigated the whole-body biodistribution and dosimetry of F-FE-PE2I in healthy volunteers to support its utility as a suitable PET imaging agent for the DAT.
View Article and Find Full Text PDFPurpose: Attenuation correction is a requirement for quantification of the activity distribution in PET. The need to base attenuation correction on MRI instead of CT has arisen with the introduction of integrated PET/MRI systems. The aim was to describe the effect of residual gradient field nonlinearity distortions on PET attenuation correction.
View Article and Find Full Text PDFPurpose: This work describes PETSTEP (PET Simulator of Tracers via Emission Projection): a faster and more accessible alternative to Monte Carlo (MC) simulation generating realistic PET images, for studies assessing image features and segmentation techniques.
Methods: PETSTEP was implemented within Matlab as open source software. It allows generating three-dimensional PET images from PET/CT data or synthetic CT and PET maps, with user-drawn lesions and user-set acquisition and reconstruction parameters.
Unlabelled: Compartmental modeling of dynamic PET data enables quantification of tracer kinetics in vivo, through the calculated model parameters. In this study, we aimed to investigate the effect of early frame sampling and reconstruction method on pharmacokinetic parameters obtained from a 2-tissue model, in terms of bias and uncertainty (SD).
Methods: The GATE Monte Carlo software was used to simulate 2 × 15 dynamic 3'-deoxy-3'-(18)F-fluorothymidine ((18)F-FLT) brain PET studies, typical in terms of noise level and kinetic parameters.
Purpose: The aim of this study was to investigate the effect of scatter and its correction on kinetic parameters in dynamic brain positron emission tomography (PET) tumor imaging. The 2-tissue compartment model was used, and two different reconstruction methods and two scatter correction (SC) schemes were investigated.
Methods: The gate Monte Carlo (MC) software was used to perform 2 × 15 full PET scan simulations of a voxelized head phantom with inserted tumor regions.
We prospectively evaluated the diagnostic contribution of (123)I-FP-Cit (DAT) and (123)I-IBZM (IBZM) SPECT in 29 patients with Parkinson's disease (PD) (74.4 ± 4.2 years) and 28 patients with atypical parkinsonian diseases (APD) (74.
View Article and Find Full Text PDFThe contribution of various brain areas to the overall progression of Parkinson's disease remains to be determined. In this study, we apply MRI diffusion tensor imaging to investigate how alterations in diffusion relate to phenotype and symptoms measured by clinical rating scales. Sixty-four patients were investigated at baseline and three follow-ups (1, 3 and 5 years).
View Article and Find Full Text PDFObjective: The need for age-adjusted and/or sex-adjusted reference values in dopamine transporter (DAT) and dopamine D2 receptor (D2R) imaging with single-photon emission computed tomography (SPECT) in a longitudinal study of parkinsonian diseases was investigated. We used two different image evaluation tools with a cross-sectional and longitudinal statistical approach.
Materials And Methods: Baseline DAT and/or D2R SPECT were performed in 51 healthy controls (HC), age-matched to patients in an ongoing prospective study on idiopathic parkinsonism.
Unlabelled: In PET, partial-volume effects cause errors in estimation of size and activity for small objects with radiopharmaceutical uptake. Recent methods for image reconstruction, compared with traditional reconstruction techniques, include algorithms for resolution recovery that result in images with higher resolution and enable quantification of size and activity of smaller objects. The purpose of this study was to evaluate a combination of 2 algorithms for volume delineation and partial-volume correction on uptake volumes smaller than 0.
View Article and Find Full Text PDFBackground: In (123)I-Iolopride (IBZM) SPECT reference values may diverge between camera systems. If multicenter pooling of normal material databases is needed, differences in measured semi-quantitative data due to equipment performance and reconstruction parameters have to be investigated in each instance to determine the comparability.
Purpose: To explore the differences in (123)I-IBZM measured uptake ratios between two different gamma cameras in healthy controls, the intra-rater reproducibility of the image evaluation method and the possibility to equalize uptake ratios by calibration through an anthropomorphic phantom.
Executive control coordinates, prioritizes, and selects task-relevant representations under conditions of conflict. Behavioral evidence has documented that executive resources are separable, finite, and can be temporarily depleted; however, the neural basis for such resource limits are largely unknown. Here, we investigate the neural correlates underlying the fatigue or depletion of interference control, an executive process hypothesized to mediate competition among candidate memory representations.
View Article and Find Full Text PDFUnlabelled: In dopamine brain SPECT, semiquantitative techniques are in use, mostly for research purposes, to calculate activity uptake in the striatum relative to the background. The measured uptake ratios depend on both acquisition and reconstruction, and one important parameter is the rotation radius of the γ-camera detectors, which affects spatial resolution. In brain SPECT research studies, the rotation radius is typically set to a constant value to maintain a constant resolution, but because of variations in patient anatomy and compliance, this is not always possible.
View Article and Find Full Text PDFObject: The aim of this study was to evaluate MR-based attenuation correction of PET emission data of the head, based on a previously described technique that calculates substitute CT (sCT) images from a set of MR images.
Materials And Methods: Images from eight patients, examined with (18)F-FLT PET/CT and MRI, were included. sCT images were calculated and co-registered to the corresponding CT images, and transferred to the PET/CT scanner for reconstruction.
Objective: External lumbar drainage (ELD) of CSF is a test to determine the suitability of a shunt for patients with normal pressure hydrocephalus (NPH), but its effect on ventricular volume is not known. This study investigates the effect of 3-day ELD of 500 mL on ventricular size and clinical features in patients with idiopathic NPH.
Methods: Fifteen patients were investigated in a 1.
Deficits in executive functioning and working memory associated with frontal lobe dysfunction are prominent in depression and work-related long-term sick leave (LTSL). This study used functional magnetic resonance imaging (fMRI) to investigate potential differences in brain activation patterns in these conditions. In addition, the function of the hypothalamic-pituitary-adrenal (HPA) axis was examined and compared between groups.
View Article and Find Full Text PDFRecent studies implicate regions in the frontal, temporal and occipital cortices of the brain in audio-visual (AV) integration of familiar objects. It remains unclear, however, which brain regions contribute to the creation of object-related AV memories, and whether activation of these regions is affected by crossmodal congruency. Here we used event-related functional MRI in a subsequent memory paradigm to investigate the neural substrates of successful encoding of semantically congruent and incongruent AV memories.
View Article and Find Full Text PDFBackground: Idiopathic normal-pressure hydrocephalus (INPH) is associated with white matter lesions, but the extent and severity of the lesions do not cohere with symptoms or improvement after shunting, implying the presence of further, yet undisclosed, injuries to white matter in INPH.
Objective: To apply diffusion tensor imaging (DTI) to explore white matter lesions in patients with INPH before and after drainage of cerebrospinal fluid (CSF).
Methods: Eighteen patients and 10 controls were included.
Eur J Nucl Med Mol Imaging
November 2010
Purpose: The aim of this study was to assess the diagnostic contribution of pre- and postsynaptic dopamine SPECT in drug-naïve patients with early idiopathic parkinsonism and to investigate possible differences between idiopathic Parkinson's disease (PD) and atypical parkinsonian syndromes (APS) and possible differences in motor subtypes of parkinsonism.
Methods: A group of 128 newly diagnosed idiopathic parkinsonian patients and 48 healthy controls was studied. Presynaptic baseline SPECT with (123)I-FP-CIT was performed in all patients and in 120 patients also a baseline postsynaptic SPECT with (123)I-IBZM.
In (123)I-IBZM brain SPECT, the main interest is the activity uptake in the striatum relative to the background, and semi-quantitative techniques using regions of interest are typically used for this purpose. Uncertainties in the measured uptakes can however be a problem due to low contrasts and high noise levels. Like SPECT in general, IBZM SPECT should benefit from reconstruction methods that include model-based compensation, but it is important that image acquisition is optimized for this technique.
View Article and Find Full Text PDFThe catechol O-methyltransferase (COMT) gene--encoding an enzyme that is essential for the degradation of dopamine (DA) in prefrontal cortex (PFC)--contains a single nucleotide polymorphism (val/met) important for cognition. According to the tonic-phasic hypothesis, individuals carrying the low-enzyme-activity allele (met) are characterized by enhanced tonic DA activity in PFC, promoting sustained cognitive representations in working memory. Val carriers have reduced tonic but enhanced phasic dopaminergic activity in subcortical regions, enhancing cognitive flexibility.
View Article and Find Full Text PDF