Hepatitis C virus (HCV) infection can have serious consequences when untreated and diagnosis is the first step in any treatment regimen. In the Unites States a 2-step algorithm consisting of HCV antibody screening and HCV RNA testing of HCV antibody-reactive specimens is recommended for detection of current HCV infection. We conducted a survey of HCV diagnostic practices in US public health laboratories and convened a meeting of HCV subject matter experts to identify opportunities for improvement in HCV diagnosis.
View Article and Find Full Text PDFAutomated nontreponemal rapid plasma reagin (RPR) tests were recently introduced in the United States for syphilis testing and limited performance data are available. In collaboration with the Association of Public Health Laboratories, three public health laboratories (PHL) were chosen through a competitive selection process to evaluate the performance of three FDA-cleared automated RPR test systems: BioPlex 2200 Syphilis Total & RPR assay (Bio-Rad Laboratories), AIX 1000 (Gold Standard Diagnostics), and ASI Evolution (Arlington Scientific). Panels prepared at the CDC included: a qualitative panel comprised of 734 syphilis reactive/nonreactive sera; a quantitative panel of 50 syphilis reactive sera (RPR titer 1:64 to 1:1,024); and a reproducibility panel of 15 nonreactive and reactive sera (RPR titer 1:1 to 1:64).
View Article and Find Full Text PDFDirect-to-consumer test services have gained popularity for sexually transmitted infections in recent years, with substantially increased use as a result of the SARS-CoV-2 (CoVID-19) global pandemic. This method of access has been variously known as "self-testing," "home testing," and "direct access testing." Although these online services may be offered through different mechanisms, here we focus on those that are consumer-driven and require self-collected samples, and sample shipment to a centralized laboratory without involvement of health care providers and/or local health departments.
View Article and Find Full Text PDFBackground: Adherence to recommended laboratory testing practices is crucial for sexually transmitted infection prevention and control. The objective of this article is to compare Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) testing practices of US clinical laboratories in 2013 before the updated 2014 Centers for Disease Control and Prevention recommendations and in 2015 after the updated recommendations.
Methods: A total of 236 clinical laboratories participated in surveys about their 2013 and 2015 CT and NG testing practices, including questions on specimen types collected and assays used.
U.S. gonorrhea rates are rising, and antibiotic-resistant (AR-Ng) is an urgent public health threat.
View Article and Find Full Text PDFSex Transm Dis
February 2020
Background: Laboratory testing practices are an important part of sexually transmitted disease (STD) diagnosis and control. The goal of this article is to describe the volume and types of STD tests performed in public health laboratories (PHLs) in the United States in 2016.
Methods: A total of 105 state and local PHLs who were members of the Association of Public Health Laboratories were invited to participate in a survey between May and August 2017.
Background: In 2016, HIV-2 nucleic acid testing (NAT) was added to a shared service program that conducts HIV-1 NAT for public health laboratories performing the recommended algorithm for diagnosing HIV. Here, we evaluate the usefulness of HIV-2 NAT in this program as compared with HIV-1 NAT.
Methods: Specimens eligible for HIV-1 NAT were reactive on an HIV-1/2 antibody or antigen/antibody initial test and nonreactive or indeterminate on a supplemental antibody test or were reactive for HIV-1 antigen-only on an HIV-1/2 antigen/antibody initial test.
The Centers for Disease Control and Prevention's (CDC) Division of STD Prevention, in collaboration with the Association of Public Health Laboratories (APHL), is developing a nationally available syphilis serum repository for research of Food and Drug Administration (FDA)-cleared or investigational syphilis diagnostic assays in the United States. State and local public health laboratories (PHL) submitted de-identified residual sera with information on collection date, volume, storage conditions, freeze-thaw cycles, PHL serology results, reported syphilis stage and demographic details if available. Previous test results were blinded and sera (N = 152 reported syphilis stage, N = 131 unknown status) were tested at CDC using five FDA-cleared and one investigational syphilis tests.
View Article and Find Full Text PDFBackground: In this study, we evaluate the performance of the Syphilis Health Check (SHC) in clinical and laboratory settings using fingerstick whole blood and serum.
Methods: Fingerstick whole blood and serum specimens from adult patients (n = 562) without prior syphilis history presenting at 2 county health department STD clinics in North Carolina were tested. Fingerstick specimens were tested with the SHC in clinic, and serum specimens were tested at the North Carolina State Laboratory of Public Health with: (1) qualitative rapid plasma reagin, (2) treponemal EIA, and (3) SHC.
Background: The capacity of HIV Antigen/Antibody (Ag/Ab) immunoassays (IA) to detect HIV-1 p24 antigen has resulted in improved detection of HIV-1 infections in comparison to Ab-only screening assays. Since its introduction in the US, studies have shown that the Determine HIV-1/2 Ag/Ab Combo assay (Determine Ag/Ab) detects HIV infection earlier than laboratory-based IgM/IgG-sensitive IAs, but its sensitivity for HIV-1 p24 Ag detection is reduced compared to laboratory-based Ag/Ab assays. However, further evaluation is needed to assess its capacity to detect acute HIV-1 infection.
View Article and Find Full Text PDFHurricane Maria made landfall in Puerto Rico on September 20, 2017, causing major damage to infrastructure and severely limiting access to potable water, electric power, transportation, and communications. Public services that were affected included operations of the Puerto Rico Department of Health (PRDOH), which provides critical laboratory testing and surveillance for diseases and other health hazards. PRDOH requested assistance from CDC for the restoration of laboratory infrastructure, surveillance capacity, and diagnostic testing for selected priority diseases, including influenza, rabies, leptospirosis, salmonellosis, and tuberculosis.
View Article and Find Full Text PDFDiagn Microbiol Infect Dis
October 2016
Four commercial transport systems for the recovery of Neisseria gonorrhoeae were evaluated in support of the need to obtain culture isolates for the detection of antimicrobial resistance. Bacterial recovery from the InTray GC system was superior with minimal loss of viability in contrast to non-nutritive transport systems.
View Article and Find Full Text PDFWe characterized the genome of a highly divergent gyrovirus (GyV8) in the spleen and uropygial gland tissues of a diseased northern fulmar (Fulmarus glacialis), a pelagic bird beached in San Francisco, California. No other exogenous viral sequences could be identified using viral metagenomics. The small circular DNA genome shared no significant nucleotide sequence identity, and only 38-42 % amino acid sequence identity in VP1, with any of the previously identified gyroviruses.
View Article and Find Full Text PDFBackground: Human adenoviruses of species B, C, and E (HAdV-B, -C, -E) are frequent causative agents of acute respiratory infections worldwide. As part of a surveillance program aimed at identifying the etiology of influenza-like illness (ILI) in Egypt, we characterized 105 adenovirus isolates from clinical samples collected between 2003 and 2010.
Methods: Identification of the isolates as HAdV was accomplished by an immunofluorescence assay (IFA) and confirmed by a set of species and type specific polymerase chain reactions (PCR).
Background: During October 2010, Egypt reported an outbreak of acute hemorrhagic conjunctivitis (AHC). A total of 1831 cases were reported from three governorates; 1703 cases in El Daqahliya, 92 cases in Port Said, and 36 in Damietta. The purpose of this study was to identify and characterize the causative agent associated with this outbreak.
View Article and Find Full Text PDFWe analyzed highly pathogenic avian influenza A(H5N1) viruses isolated from humans infected in Egypt during 2007-2011. All analyzed viruses evolved from the lineage of subtype H5N1 viruses introduced into Egypt in 2006; we found minimal evidence of reassortment and no exotic introductions. The hemagglutinin genes of the viruses from 2011 formed a monophyletic group within clade 2.
View Article and Find Full Text PDFBackground: A specific diagnosis of a lower respiratory viral infection is often difficult despite frequent clinical suspicion. This low diagnostic yield may be improved by use of sensitive detection methods and biomarkers.
Methods: The prevalence, clinical predictors and inflammatory mediator profile of respiratory viral infection in serious acute respiratory illness were investigated.
WU polyomavirus is a recently described polyomavirus found in patients with respiratory infections. Of 2,637 respiratory samples tested in St. Louis, Missouri, 2.
View Article and Find Full Text PDFWe report the identification of a novel polyomavirus present in respiratory secretions from human patients with symptoms of acute respiratory tract infection. The virus was initially detected in a nasopharyngeal aspirate from a 3-year-old child from Australia diagnosed with pneumonia. A random library was generated from nucleic acids extracted from the nasopharyngeal aspirate and analyzed by high throughput DNA sequencing.
View Article and Find Full Text PDFTissue and organ replacement have quickly outpaced available supply. Tissue bioengineering holds the promise for additional tissue availability. Various scaffolds are currently used, whereas polyglycolic acid (PGA), which is currently used in absorbable sutures and orthopedic pins, provides an excellent support for tissue development.
View Article and Find Full Text PDFEnviron Geochem Health
December 2004
Variation in sediment metal concentrations in the River Avoca, which is severely polluted by acid mine drainage (AMD) discharged from the abandoned sulphur and copper mines in Avoca, is reported. A survey of surface and subsurface sediments was repeated after seven years during exceptionally low flow conditions in 2001. The present study found that the reference (up-stream) site used in the original 1994 study was itself impacted by AMD, showing sediment metal enrichment by AMD to be greater than originally thought.
View Article and Find Full Text PDF