Publications by authors named "Anne E C M Saris"

Objective: Local flow dynamics impact atherosclerosis yet are difficult to quantify with conventional ultrasound techniques. This study investigates the performance of ultrasound vector flow imaging (US-VFI) with and without ultrasound contrast agents in the healthy femoral bifurcation.

Methods: High-frame-rate ultrasound data with incremental acoustic outputs were acquired in the femoral bifurcations of 20 healthy subjects before (50V) and after contrast injection (2V, 5V and 10V).

View Article and Find Full Text PDF

Arteriosclerosis results from lipid buildup in artery walls, leading to plaque formation, and is a leading cause of death. Plaque rupture can cause blood clots that might lead to a stroke. Distinguishing plaque types is a challenge, but ultrasound (US) elastography can help by assessing plaque composition based on strain values.

View Article and Find Full Text PDF

With the huge progress in micro-electronics and artificial intelligence, the ultrasound probe has become the bottleneck in further adoption of ultrasound beyond the clinical setting (e.g. home and monitoring applications).

View Article and Find Full Text PDF

Cascaded dual-polarity waves (CDWs) imaging increases the signal-to-noise ratio (SNR) by transmitting trains of pulses with different polarity order, which are combined via decoding afterward. This potentially enables velocity vector imaging (VVI) in more challenging SNR conditions. However, the motion of blood in between the trains will influence the decoding process.

View Article and Find Full Text PDF

Background And Objective: Ultrasound based blood velocity estimation is a continuously developing frontier, where the vast number of possible acquisition setups and velocity estimators makes it challenging to assess which combination is better suited for a given imaging application. FLUST, the Flow-Line based Ultrasound Simulation Tool, may be used to address this challenge, providing a common platform for evaluation of velocity estimation schemes on in silico data. However, the FLUST approach had some limitations in its original form, including reduced robustness for phase sensitive setups and the need for manual selection of integrity parameters.

View Article and Find Full Text PDF

Ultrasound-based local pulse wave velocity (PWV) estimation, as a measure of arterial stiffness, can be based on fast focused imaging (FFI) or plane wave imaging (PWI). This study was aimed at comparing the accuracy of in vivo PWV estimation using FFI and PWI. Ultrasound radiofrequency data of carotid arteries were acquired in 14 healthy volunteers (25-57 y) by executing the FFI (12 lines, 7200 Hz) and PWI (128 lines, 2000 Hz) methods consecutively.

View Article and Find Full Text PDF

Visualization and quantification of blood flow are considered important for early detection of atherosclerosis and patient-specific diagnosis and intervention. As conventional Doppler imaging is limited to 1-D velocity estimates, 2-D and 3-D techniques are being developed. We introduce an adaptive velocity compounding technique that estimates the 2-D velocity vector field using predominantly axial displacements estimated by speckle tracking from dual-angle plane wave acquisitions.

View Article and Find Full Text PDF

Atherosclerotic plaque development in the carotid artery bifurcation elevates the risk for stroke, which is often initiated by plaque rupture. The risk-to-rupture of a plaque is related to its composition. Two-dimensional non-invasive carotid elastography studies have found a correlation between wall strain and plaque composition.

View Article and Find Full Text PDF

Plaque strain and blood vector velocity imaging of stenosed arteries are expected to aid in diagnosis and prevention of cerebrovascular disease. Ultrafast plane wave imaging enables simultaneous strain and velocity estimation. Multiple ultrasound vendors are introducing high-frequency ultrasound probes and systems.

View Article and Find Full Text PDF

Conventional color Doppler imaging is limited, since it only provides velocity estimates along the ultrasound beam direction for a restricted field of view at a limited frame rate. High-frame-rate speckle tracking, using plane wave transmits, has shown potential for 2-D blood velocity estimation. However, due to the lack of focusing in transmit, image quality gets reduced, which hampers speckle tracking.

View Article and Find Full Text PDF

Three-dimensional (3-D) strain estimation might improve the detection and localization of high strain regions in the carotid artery (CA) for identification of vulnerable plaques. This paper compares 2-D versus 3-D displacement estimation in terms of radial and circumferential strain using simulated ultrasound (US) images of a patient-specific 3-D atherosclerotic CA model at the bifurcation embedded in surrounding tissue generated with ABAQUS software. Global longitudinal motion was superimposed to the model based on the literature data.

View Article and Find Full Text PDF

Ultrasound imaging can be used to estimate the morphology as well as the motion and deformation of tissues. If the interrogated tissue is actively deforming, this deformation is directly related to its function and quantification of this deformation is normally referred as 'strain imaging'. Tissue can also be deformed by applying an internal or external force and the resulting, induced deformation is a function of the mechanical tissue characteristics.

View Article and Find Full Text PDF

For automated segmentation of 3-D echocardiographic images, incorporation of temporal information may be helpful. In this study, optimal settings for calculation of temporal cross-correlations between subsequent time frames were determined, to obtain the maximum cross-correlation (MCC) values that provided the best contrast between blood and cardiac tissue over the entire cardiac cycle. Both contrast and boundary gradient quality measures were assessed to optimize MCC values with respect to signal choice (radiofrequency or envelope data) and axial window size.

View Article and Find Full Text PDF

Purpose: Increased microvascularization of the abdominal aortic aneurysm (AAA) vessel wall has been related to AAA progression and rupture. The aim of this study was to compare the suitability of three pharmacokinetic models to describe AAA vessel wall enhancement using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI).

Materials And Methods: Patients with AAA underwent DCE-MRI at 1.

View Article and Find Full Text PDF