Publications by authors named "Anna-Maria Pistritto"

Background: Chronic thromboembolic pulmonary hypertension (CTEPH) is characterized by obstruction of major pulmonary arteries with organized thrombi. Clinical risk factors for pulmonary hypertension due to left heart disease including metabolic syndrome, left-sided valvular heart disease, and ischemic heart disease are common in CTEPH patients.

Objectives: The authors sought to investigate prevalence and prognostic implications of elevated left ventricular filling pressures (LVFP) in CTEPH.

View Article and Find Full Text PDF

Background: The pulmonary artery (PA) to ascending aorta diameter ratio (PA:A) has been evaluated in numerous studies analyzing cardiac magnetic resonance (CMR) and computed tomography (CT) data. Previously, no transthoracic echocardiography (TTE) cutoffs have been published. We sought to evaluate (1) the feasibility to image the pulmonary trunk in a prospective cohort, and (2) the ability of PA:A derived by TTE to predict pulmonary hypertension (PH).

View Article and Find Full Text PDF

Echocardiographic assessment of diastolic dysfunction depends on surrogate parameters. In recent years, guideline committees attempted to combine these parameters to diagnostic flowcharts allowing for correct classification of left ventricular filling pressures (LVFP). The value of these diagnostic tools is limited if the applied surrogate parameters are elevated due to other reasons as is the case with maximal tricuspid regurgitation velocity.

View Article and Find Full Text PDF

The commonest cause of pulmonary hypertension (PH) is left heart disease (LHD). The current classification system for definitions of PH-LHD is under review. We therefore performed prospective in-depth invasive haemodynamic phenotyping in order to assess the site of increased pulmonary vascular resistance (PVR) in PH-LHD subsets.

View Article and Find Full Text PDF

Pulmonary hypertension (PH) is a disease with severe morbidity and mortality. Echocardiography plays an essential role in the screening of PH. The quality of the acquired continuous wave Doppler signal is the major limitation of the method and can greatly affect the accuracy of estimated pulmonary pressures.

View Article and Find Full Text PDF

The Ultimaster coronary stent system (Terumo Corporation, Tokyo, Japan) represents a new iteration in drug-eluting stent (DES) technology that has recently received the Conformité Européenne (CE) mark approval for clinical use. The Ultimaster is a thin-strut, cobalt chromium, biodegradable-polymer, sirolimus-eluting coronary stent. The high elasticity of the biodegradable-polymer (PDLLA-PCL) and the abluminal gradient coating technology are additional novel features of this coronary device.

View Article and Find Full Text PDF

Aims: To appraise the early effect of percutaneous mitral valve repair with the MitraClip system on myocardial function using real-time three-dimensional speckle-tracking echocardiography (3D-STE).

Methods: Consecutive patients with moderate-to-severe or severe mitral regurgitation, undergoing mitral valve repair with the MitraClip system, were prospectively evaluated during the peri-procedural workout and follow-up. Left ventricular deformation was evaluated by a two-dimensional and 3D speckle-tracking analysis.

View Article and Find Full Text PDF

Rationale: Patients with pulmonary hypertension due to left heart disease (PH-LHD) and a diastolic pulmonary vascular pressure gradient ≥ 7 mm Hg, representing PH out of proportion to pulmonary arterial wedge pressure, have pulmonary vascular disease and increased mortality. Little information exists on this condition, recently labeled as "combined pre- and post-capillary PH" (Cpc-PH).

Objectives: To investigate epidemiology, risk factors, right ventricular function, and outcomes in patients with chronic heart failure and Cpc-PH.

View Article and Find Full Text PDF

Objectives: This study sought to compare, in high-risk patients with 3+ to 4+ mitral regurgitation (MR) dichotomized by baseline echocardiographic features, acute, 30-day, and 12-month outcomes following percutaneous mitral valve repair using the MitraClip.

Background: The feasibility and mid-term outcomes after MitraClip implantation in patients with echocardiographic features different from the EVEREST (Endovascular Valve Edge-to-Edge Repair) I and II trials have been scarcely studied.

Methods: Clinical and echocardiographic outcomes through 12-month follow-up of consecutive patients who underwent MitraClip implantation were obtained from an ongoing prospective registry.

View Article and Find Full Text PDF

Objectives: To assess the influence of patients' gender on the outcomes of percutaneous edge-to-edge mitral valve repair (PMVR) using the MitraClip system.

Background: Although gender-related differences have been extensively documented in patients who undergo surgery for moderate-to-severe (3+) and severe (4+) mitral regurgitation (MR), studies assessing whether these differences exist after PMVR are lacking.

Methods: Clinical and echocardiographic data through 12-month follow up from 171 consecutive patients whom underwent MitraClip implantation and were dichotomized by the gender (106 males and 65 females) were obtained.

View Article and Find Full Text PDF

Background: Successful mitral valve surgical repair, decreasing volume overload, has been shown to provide reverse left ventricular (LV) and/or left atrial remodeling in most patients. Percutaneous mitral valve repair with the MitraClip system (Abbott, Abbott Park, IL) has been associated with favorable clinical outcomes in patients with mitral regurgitation at high risk of surgery. However, specific data on left cardiac chambers reverse remodeling after such procedures are limited.

View Article and Find Full Text PDF

Background: Multislice computed tomography (MSCT) has generally been accepted as the most accurate modality fulfilling this purpose with good reproducibility. A major drawback of MSCT consists in the use of contrast dye, which may be unsafe in transcatheter aortic valve implantation (TAVI) patients who frequently are affected by renal failure. We sought to appraise the accuracy of intracardiac echocardiography (ICE) in measurements of structures in the aortic root in patients undergoing TAVI.

View Article and Find Full Text PDF

Aims: Prosthesis dislocation during transcatheter aortic valve implantation (TAVI) is a rare but important complication. There is scarce data on the performance of prosthesis in the aorta that have become dislocated from their intended anatomical position in the aortic annulus. We investigated the causes of dislocation during TAVI of the self-expanding CoreValve ReValving™ System (CRS) (Medtronic Inc.

View Article and Find Full Text PDF

Comparisons of transcatheter aortic valve implantation (TAVI) to surgical aortic valve replacement (SAVR) in patients with severe aortic stenosis remain sparse or limited by a short follow-up. We sought to evaluate early and midterm outcomes of consecutive patients (n = 618) undergoing successful TAVI (n = 218) or isolated SAVR (n = 400) at 2 centers. The primary end point was incidence of Valvular Academic Research Consortium-defined major adverse cerebrovascular and cardiac events (MACCEs) up to 1 year.

View Article and Find Full Text PDF

Background: Percutaneous valve repair with MitraClip System is an emerging alternative for high surgical risk patients with severe mitral regurgitation (MR). QoL is a critical measure of effectiveness of this procedure. We sought to evaluate quality of life (QoL) and NYHA class following this novel procedure.

View Article and Find Full Text PDF

Aims: Transcatheter aortic valve implantation (TAVI) is an emerging alternative to medical therapy reserved to a limited population with severe aortic stenosis. Quality-of-life (QoL) is a critical measure of effectiveness of TAVI in this patient population. In this prospective study, we sought to assess one year changes in QoL in patients who underwent TAVI.

View Article and Find Full Text PDF

Dual antiplatelet therapy (DAPT) with clopidogrel and aspirin is a widely accepted strategy in patients undergoing transcatheter aortic valve implantation (TAVI), but this approach is not evidence based. The goal of the present study was to determine whether DAPT in patients undergoing TAVI is associated with improved outcomes compared to aspirin alone. From May 2009 to August 2010, consecutive patients were randomized to receive a 300-mg loading dose of clopidogrel on the day before TAVI followed by a 3-month maintenance daily dose of 75 mg plus aspirin 100 mg lifelong (DAPT group) or aspirin 100 mg alone (ASA group).

View Article and Find Full Text PDF

Background: Transcatheter aortic valve implantation (TAVI) carries higher risk of post-procedural adverse events than conventional percutaneous cardiovascular interventions. We report our experience about postoperative management protocol adopted in our Division.

Methods: One hundred and ten patients underwent TAVI and 108 were transferred to the cardiac intensive care unit (CICU) after procedure.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve implantation (TAVI) is an emerging alternative to palliative medical therapy for nonsurgical patients with severe aortic stenosis. There is a paucity of detailed data on the management and outcome of complications related to the sub-optimal deployment of the prosthesis. We appraised the incidence and management of early implant failure occurring during TAVI.

View Article and Find Full Text PDF