Publications by authors named "Anna Traub"

Background: Very high-power short-duration (vHP-SD) radiofrequency (RF) ablation of atrial fibrillation (AF) treatment by pulmonary vein isolation (PVI) aims for safer, more effective and faster procedures. Although acute efficacy and safety for PVI was recently shown data on chronic PVI durability is limited. Here chronic PVI durability was evaluated during repeat electrophysiological procedures in patients after initial vHP-SD and conventional RF based PVI.

View Article and Find Full Text PDF

Introduction: Atrio-esophageal fistula after esophageal thermal injury (ETI) is one of the most devastating complications of available energy sources for atrial fibrillation (AF) ablation. Pulsed field ablation (PFA) uses electroporation as a new energy source for catheter ablation with promising periprocedural safety advantages over existing methods due to its unique myocardial tissue sensitivity. In preclinical animal studies, a dose-dependent esophageal temperature rise has been reported.

View Article and Find Full Text PDF

Aims: Catheter ablation with a cryoballoon (CB) provides effective and durable pulmonary vein (PV) isolation (PVI) associated with encouraging clinical outcome data. The novel POLARx CB incorporates unique features, which may translate into improved safety, efficacy, and outcomes. The ICE-AGE-1 study aimed to assess the efficacy, safety, and 1-year clinical follow-up of the POLARx CB in comparison to the Arctic Front Advance Pro CB (AF-CB4).

View Article and Find Full Text PDF

Chylothorax is a consequence of a thoracic duct injury that can occur during surgical procedures in patients with congenital heart disease. It is associated with high rates of morbimortality and increased use of clinical and hospital resources. The aim of this study was to evaluate the risk factors, distribution, manifestations, complications, and treatments for chylothorax in patients undergoing cardiac surgery in a tertiary pediatric hospital in southern Brazil.

View Article and Find Full Text PDF

Background: Wide antral circumferential ablation (WACA) in comparison to ostial pulmonary vein (PV) isolation (PVI) has been attributed with improved rhythm outcome. We investigated the feasibility, lesion formation, and rhythm outcome of WACA-PVI in comparison to ostial-PVI using pulsed field ablation (PFA).

Methods: Symptomatic atrial fibrillation (AF) patients (69 years, 67% male; 67% paroxysmal AF) were prospectively enrolled into our single-center registry and underwent first-time ostial-PFA or WACA-PFA,  = 15 each.

View Article and Find Full Text PDF

Objectives: We sought to assess the efficacy, safety and short-term clinical outcome of very high-power short-duration (vHP-SD) radiofrequency (RF) catheter ablation for the treatment of idiopathic PVCs originating from the cardiac outflow tract (OT).

Background: Power-controlled RF ablation is a widely used technique for the treatment of premature ventricular contractions (PVCs). A novel ablation catheter offers three microelectrodes and six thermocouples at its tip and provides temperature-controlled vHP-SD (90 Watts/4 s,) with the opportunity to switch to moderate-power mode.

View Article and Find Full Text PDF

The new European Society of Cardiology (ESC) guidelines on cardiac pacing and cardiac resynchronization therapy were presented together with the new ESC heart failure guidelines at the ESC congress in September. The new document includes detailed sections on patient evaluation and clinical assessment, implantation, minimizing complications and patient follow-up. The guidelines have been updated and expanded particularly on the approach to reflex syncope, the indications after transcatheter aortic valve implantation (TAVI) and the perioperative management.

View Article and Find Full Text PDF

Aims: Cryoballoon (CB) based pulmonary vein isolation (PVI) is a widely used technique for treatment of atrial fibrillation (AF); however the ideal energy dosing has not yet been standardized. This was a single-centre randomized clinical trial aiming at assessing the safety, acute efficacy, and clinical outcome of an individualized vs. a fixed CB ablation protocol using the fourth-generation CB (CB4) guided by pulmonary vein (PV) potential recordings and CB temperature.

View Article and Find Full Text PDF

A 80-year-old female patient with symptomatic atrial tachycardia develops cold sweat and hypotension in the recovery room after pulmonary vein isolation. The procedure included an anterior line and an endo- and epicardial mitral isthmus line. Echocardiography excluded a hemodynamically relevant pericardial effusion.

View Article and Find Full Text PDF

Background: Catheter ablation for atrial fibrillation (AF) treatment provides effective and durable pulmonary vein isolation (PVI) and is associated with encouraging clinical outcome. A novel CF sensing temperature-controlled radiofrequency (RF) ablation catheter allows for very high-power short-duration (vHP-SD, 90 W/4 s) ablation aiming a potentially safer, more effective and faster ablation. We thought to evaluate preliminary safety and efficacy of vHP-SD ablation for PVI utilizing a novel vHP-SD catheter.

View Article and Find Full Text PDF

Background: The second-generation cryoballoon (CB2) provides effective and durable pulmonary vein isolation (PVI) associated with encouraging clinical outcome. The novel fourth-generation cryoballoon (CB4) incorporates a 40% shorter distal tip. This design change may translate into an increased rate of PVI real-time signal recording, facilitating an individualized ablation strategy using the time to effect (TTE).

View Article and Find Full Text PDF