The implantation of a subcutaneous cardioverter-defibrillator (S-ICD) may be used instead of a traditional transvenous system to prevent sudden cardiac death. Our aim was to compare the characteristics of S-ICD patients from the multi-center registry of S-ICD implantations in Poland with the published results of the European Snapshot Survey on S-ICD Implantation (ESSS-SICDI). We compared data of 137 Polish S-ICD patients with 68 patients from the ESSS-SICDI registry.
View Article and Find Full Text PDFObjective The aim of this study was to evaluate the incidence of venous stenosis and occlusion (VSO) in patients referred for transvenous lead extraction (TLE) with regard to the indications for this treatment and to analyse the influence of VSO on efficacy, complications and technical challenges of TLE procedures. Methods The material consists of 133 consecutive TLE procedure records. The contrast venography examination of the ipsilateral access vein was performed prior to the operation.
View Article and Find Full Text PDFUnlabelled: The task of the ICD is to detect ventricular arrhythmias and treatment of its adequate intervention. The task of the CRTD in addition to the above tasks is the treatment of heart failure.
Aim: The aim of the study was to assess the predictive parameters of adequate interventions in patients with an ICD and CRTD.
Unlabelled: Telemetric follow-up (RM) after cardiac devices implantation is not inferior to classic follow-up and enables earlier clinical complications detection.
Aim: The aim of the study was to evaluation of the ventricular arrhythmias and interventions of ICD/CRTD in ambulatory and telemetric follow-up in patients with dilated cardiomyopathy.
Materials And Methods: Group A (CRT-D+ICD) - retrospective, patients followed-up in outpatient clinic - was consisted with 273 patients (mean age 65±11 years, 230M).
Unlabelled: The assessment of factors influencing occurrence of adequate interventions of cardiac resynchronization therapy with cardioverter-defibrillator implanted in primary prevention of sudden cardiac death in dilative cardiomyopathy and percentage of biventricular pacing.
Introduction: The function of cardiac resynchronization therapy with cardioverter-defibrillator (CRT-D) is to treat heart failure (HF) and to treat ventricular arrhythmia, if it occurs, with adequate intervention.
Aim: The aim of the study was to find predictors of adequate interventions and in how many patients biventricular pacing percentage decreases during the follow-up.
Background: Currently, there are no studies in which a CHA2DS2-VASc score has been used to predict the risk of venous stenosis and occlusion (VSO) in patients after the implantation of a cardiac implantable electronic device (CIED).
Methods: The material consists of the records of 223 consecutive patients qualified for transvenous lead extraction, generator change and system revisions or upgrades in whom we assessed the utility of a CHA2DS2-VASc score in the prediction of VSO. The CHA2DS2-VASc score was calculated retrospectively based on the clinical data.
Unlabelled: Ambulatory follow-up of patients with implanted cardioverter-defibrillator (ICD) with/without resynchronisation therapy (CRTD) requires regular visits to assess arrhythmias, device interventions and mortality.
Aim: The aim of the study was to examine arrhythmia prevalence, device interventions and mortality in patients with dilative cardiomyopathy with ICD/CRTD implanted in primary sudden cardiac death (SCD) prevention.
Materials And Methods: The study consisted of patients with ICD and/or CRTD implanted between 2010-2011.
Unlabelled: Telemetric follow-up (RM) after cardiac devices implantation is not only not inferior to classic follow-up, but also enables earlier clinical complications detection and stricter patient monitoring.
The Aim: of the study was to confirm safety and efficacy of RM in patients with implantable cardioverter-defibrillator (ICD) or cardioverterdefibrillator with resynchronisation therapy (CRT-D), compared to traditional follow-up in outpatient clinic.
Materials And Methods: Group A (CRT-D+ICD) (retrospective, patients followed-up in outpatient clinic) was consisted with 273 patients (mean age 65±11 years, 230M).
Background: Venous stenosis and occlusion in the presence of endocardial leads constitute one of the complications of permanent cardiac pacing either by pacemaker, implantable cardioverter-defibrillator or cardiac resynchronization therapy.
Objectives: The aim of this study was to assess the incidence of stenosis and occlusions and determine the risk factors in patients with endocardial leads in a prospective single-center study.
Material And Methods: Two hundred eighty consecutive patients aged 25-95 years (male 68.
Introduction: Remote monitoring of ICD/CRTD is safe, during which evaluates the type of arrhythmia, intervention.
Aim: The aim of the study was the assessment of ventricular arrhythmia and ICD/CRTD intervention.
Material And Methods: The study included 177 patients (mean age 61,1±13; 23-88 y; Men 141) with an ICD/CRTD implanted.
Unlabelled: Aim of the study was analysis of electrophysiological and clinical parameters related to increasement of recurrence risk of AVNRT and subjective heart feelings after successful RF ablation.
Materials And Methods: Retrospective analysis was made among patients after successful RF AVNRT ablation. Study group was 93 patients (F=63), mean age 46.
Background: According to the current guidelines, atrioventricular (DDD) pacing is superior to atrial pacing (AAI) in the treatment of sick sinus syndrome (SSS).
Aim: To compare outcomes of AAI and DDD pacing in patients with SSS during long-term follow-up.
Methods: We studied 809 patients, including 86 patients in the AAI group (57 women, mean age 65 ± 15 years) and 723 patients in the DDD group (406 women, mean age 71.
Unlabelled: Traditional implantation site for implantable cardioverter-defibrillator (ICD) is right ventricular apex (RVA). According to many data, this location ensures low enough defibrillation threshold. ICDs are more often implanted in patients with impaired left ventricle function, in whom, along with disease progression, the need for permanent stimulation develops.
View Article and Find Full Text PDFPol Merkur Lekarski
December 2013
The Aim Of Study: To assess changes in quality of life in patients with advanced heart failure before ICD or CRTD implantation and after 6 months follow-up period.
Material And Methods: The quality of life study was performed in group consisting of 98 patients (69 male, mean age 70.4 +/- 8.
We here present a case of lead dependent infective endocarditis which manifested with pacemaker pocket displacement to the left infra mammary region. The patient underwent pacemaker removal without its reimplantation.
View Article and Find Full Text PDFIntroduction: Thrombosis (VTh) is a rare dangerous complication of pacemaker implantation (PM). The aim of the study was to determine the dynamics of change in selected thrombotic and inflammatory factors after PM.
Material And Methods: The study involved 81 patients (30 female, mean age: 71.
Background: In order to achieve optimal outcomes when treating ventricular tachyarrhythmias with implantable devices, it is extremely important to identify parameters predisposing to arrhythmia. In view of current restrictions in healthcare funding, there is a growing demand for additional predictors of arrhythmia that would allow better patient selection for implantable cardioverter-defibrillator (ICD) use for primary prevention of sudden cardiac death (SCD).
Aim: To identify parameters predisposing to ventricular tachyarrhythmia/appropriate ICD intervention in ICD recipients.
Background: Proper selection of patients at high risk for sudden cardiac death (SCD) and increasing use of implantable cardioverter-defibrillators (ICD) may contribute to improved survival among patients at the highest SCD risk.
Aim: To assess patient survival rate after implantation of an ICD without resynchronisation capability in our own patient population. Using uni- and multivariate analysis, we attempted to identify factors associated with significant worsening of patient survival rate.
Unlabelled: Antitachycardia pacing (ATP) and high voltage interventions (CV) are methods of interrupting dangerous ventricular arrhythmias. The aim of the study was to determine the frequency of ventricular tachyarrhythmias and form of ICD interventions in patients in the primary and secondary sudden cardiac death (SCD) prevention groups.
Material And Methods: The study involved 399 patients (334 male, 65 female), mean age was 65.