Unlabelled: A 75-year-old man with hypertrophic obstructive cardiomyopathy underwent placement of a long-sensing vector implantable loop recorder (ILR) for unexplained syncope. One month later, ILR remote monitoring revealed unstable R-wave amplitudes ranging from very high (>1.9 mV) to very low (<0.
View Article and Find Full Text PDFAims: The study evaluated the positivity rate, haemodynamic responses, and prognosis in terms of syncopal recurrence among patients with situational syncope (SS) stratified according to the underlying situational triggers.
Methods And Results: We retrospectively evaluated all consecutive patients with SS who underwent nitroglycerine (NTG)-potentiated head-up tilt test (HUTT) at Syncope Unit of the University of Campania 'Luigi Vanvitelli'-Monaldi Hospital from 1 March 2017 to 1 May 2023. All patients were followed for at least one year.
Background: Remote monitoring is recommended for patients with implantable cardiac monitors (ICMs), but compared to other cardiac implantable devices, ICMs are less accurate and transmit a higher number of alerts.
Objective: The aim of this study was to investigate the predictors of false-positive (FP) arrhythmic alerts in patients with unexplained syncope who were implanted with ICM and followed by an automatic remote monitoring system.
Methods: We retrospectively evaluated all consecutive patients who received a long-sensing vector ICM for unexplained syncope between January 2019 to September 2021 at our Syncope Unit.
Objective: The study compared clinical characteristics and response at head-up tilt test (HUTT) between situational (SS) and vasovagal syncope (VVS).
Methods: Consecutive patients who underwent nitroglycerin-potentiated HUTT were retrospectively dichotomised into two groups: those with a history of SS and those with a history of VVS. The patients with SS were further subdivided into patients with SS alone and with SS and at least one episode of VVS.
Background: There are little data on remote monitoring (RM) of implantable loop recorders (ILRs) in patients with unexplained syncope and whether it confers enhanced diagnostic power.
Objective: To evaluate the effect of RM in ILR recipients for unexplained syncope for early detection of clinically relevant arrhythmias by comparison with a historical cohort with no RM.
Methods: SyncRM is a propensity score (PS)-matched study prospectively including 133 consecutive patients with unexplained syncope and ILR followed up by RM (RM-ON group).
Background: The traditional nitroglycerin (NTG) head-up tilt test (HUTT) is time-consuming and the test duration is a barrier to widespread utilization in clinical practice. It was hypothesized that a short-duration protocol is not inferior to the traditional protocol regarding the positivity rate and has a similar distribution of hemodynamic response.
Methods And Results: Patients undergoing HUTT were randomized 1:1 to a 10 min passive phase plus a 10 min 0.
Sudden cardiac death (SCD) is one of the leading causes of cardiovascular death in general population. SCD primary prevention requires the correct selection of patients at increased risk who may benefit from implantable cardioverter-defibrillator (ICD). Despite several non-invasive arrhythmic risk indexes are available, their ability to stratify the SCD risk among asymptomatic patients with cardiac disease at increased arrhythmic risk is debated.
View Article and Find Full Text PDFBackground: Conduction system pacing (CSP) using His bundle pacing (HBP) or left bundle branch area pacing (LBBAP) has emerged as an alternative to right ventricular pacing (RVP). Comparative data on the risk of complications between CSP and RVP are lacking.
Objective: This prospective, multicenter, observational study aimed to compare the long-term risk of device-related complications between CSP and RVP.
Atrial fibrillation (AF) is the most common cardiac arrhythmia associated with an increased thromboembolic risk. The impact of the female sex as an independent risk factor for thromboembolic events in AF is still debated. The aim of this review is to evaluate the gender-related differences in cardioembolic risk and response to anticoagulants among AF patients.
View Article and Find Full Text PDFIndian Pacing Electrophysiol J
February 2023
Inappropriate shock (IAS) is the most frequent device-related complication among patients with subcutaneous implantable cardioverter-defibrillator (S-ICD). Air entrapment (AE) has been described as an underdiagnosed cause of early postimplant IAS. We report 6 consecutive cases of early IAS after S-ICD implant, in whom the electrogram analysis (EGM) and/or chest radiography (CXR) were consistent with AE.
View Article and Find Full Text PDFWe report the case of drug-induced type 1 Brugada syndrome at high arrhythmic risk associated with Lamin A/C gene mutation.
View Article and Find Full Text PDFIntroduction: Little is still known about the positivity rate of nitroglycerin (NTG) potentiated head-up tilt test (HUTT) according to the history-based clinical features of syncope. The study aimed to compare the HUTT positivity rate and type of responses in patients with classical and non-classical vasovagal syncope (VVS).
Materials And Methods: We retrospectively evaluated all consecutive patients who underwent NTG-potentiated HUTT for VVS.
Dual pathway inhibition (DPI) with low-dose rivaroxaban and aspirin in patients with coronary artery disease (CAD) and/or peripheral artery disease (PAD) reduces the occurrence of cardiovascular (CV) events; however, the underlying mechanisms explaining these latter CV benefits are not clearly understood. Our explorative observational study aimed to evaluate the effect of dual pathway inhibition on plasma inflammation and coagulation markers among real-world patients with CAD and/or PAD. We prospectively included all consecutive patients with an established diagnosis of CAD and/or PAD treated with aspirin 100 mg once daily (OD) and rivaroxaban 2.
View Article and Find Full Text PDFBackground: Air entrapment has been recently described as a cause of inappropriate shock (IAS) among patients who underwent subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation. Data about this complication are lacking in the literature.
Methods: In this meta-summary 14 case reports describing IAS due to air entrapment were included.
Aims: Myotonic dystrophy type 1 (DM1) predisposes to the development of life-threatening arrhythmias and sudden cardiac death. Our study aimed to evaluate the prognostic value of programmed ventricular stimulation (PVS) in DM1 patients with conduction system disease.
Methods And Results: Arrhythmic CArdiac DEath in MYotonic dystrophy type 1 patients (ACADEMY 1) is a double-arm non-randomized interventional prospective study.
Introduction: In the context of randomized clinical trials, subcutaneous implantable cardiac defibrillators (S-ICDs) are non-inferior to transvenous ICDs (T-ICDs) concerning device-related complications or inappropriate shocks in patients with an indication for defibrillator therapy and not in need of pacing. We aimed at describing the clinical features of patients who underwent S-ICD implantation in our clinical practice, as well as the ICD-related complications and the inappropriate therapies among S-ICD vs. T-ICD recipients during a long-term follow-up.
View Article and Find Full Text PDFAims: The aim of our study was to evaluate the prevalence and clinical predictors of cardioinhibitory (CI) responses with asystole at the nitroglycerin (NTG)-potentiated head-up tilt test (HUTT) in patients with a history of syncope admitted to a tertiary referral syncope unit.
Methods: We retrospectively evaluated all consecutive patients who underwent NTG-potentiated HUTT for suspected reflex syncope at our institution from March 1 2017 to May 1 2020. The prevalence of HUTT-induced CI syncope was assessed.
Aim: Remote monitoring (RM) of implantable cardiac devices has enabled continuous surveillance of atrial high rate episodes (AHREs) with well-recognized clinical benefits. We aimed to add evidence on the role of the RM as compared to conventional follow-up by investigating the interval from AHRE onset to physician's evaluation and reaction time in actionable episodes.
Methods And Results: A total of 97 dual-chamber pacemaker recipients were followed with RM (RM-ON group; = 64) or conventional in-office visits (RM-OFF group; = 33) for 18 months.
Background: Although radiofrequency (RF) catheter ablation of cavo-tricuspid isthmus (CTI) is an established treatment for typical right atrial flutter (RAFL), it remains to be established whether local tissue impedance (LI) is able to predict effective CTI ablation and what LI drop values during ablation should be used to judge a lesion as effective. We aimed to investigate the ability of LI to predict ablation efficacy in patients with RAFL.
Methods: RF delivery was guided by the DirectSense™ algorithm.
Introduction: Little is known about the clinical performance of single-chamber leadless pacemaker (LLPM) in patients without atrial fibrillation (AF) as pacing indication. The aim of this study was to describe the clinical characteristics of patients who underwent single chamber LLPM implantation at three tertiary referral centers and to compare the safety and effectiveness of the single-chamber LLPM among patients with or without AF.
Materials And Methods: All the consecutive patients who underwent LLPM implantation at three referral centers were analyzed.
Aim: The aim of the present study was to assess the safety and effectiveness of non-vitamin K antagonist oral anticoagulants (NOACs) versus vitamin K antagonists (VKAs) in atrial fibrillation (AF) patients undergoing electrical cardioversion (EC).
Methods: A propensity score-matched analysis was performed in order to identify two homogeneous groups including AF patients on NOACs and VKAs treatment scheduled for EC. The primary safety endpoint was major bleeding.
Measurement of direct oral anticoagulants (DOACs) activity is not routinely necessary. Indeed, evaluation of DOACs plasmatic concentration is discouraged for the majority of patients, due to the lack of outcome data supporting this approach. Nevertheless, DOAC measurements may be useful in emergency situations such as serious bleeding events, need for urgent invasive procedures, and acute ischemic stroke or in managing anticoagulation in "special populations" not adequately studied in clinical trials, for example the very elderly or those at the extremes of body weight.
View Article and Find Full Text PDF