The purpose of the present investigation was to compare the acute responses on muscle architecture, electromechanical delay (EMD) and performance following a high volume (HV: 5 sets of 10 reps at 70% of 1 repetition maximum (1RM)) and a high intensity (HI: 5 sets of 3 reps at 90% of 1RM) bench press protocol in women. Eleven recreationally trained women (age = 23.3 ± 1.
View Article and Find Full Text PDFBackground: Walking on compliant surfaces, on sand in particular, is now recommended for training in both elderlies and injured subjects/individuals, allowing to perform high intensity exercises (i.e. augmented energy expenditure) in safe conditions (i.
View Article and Find Full Text PDFWhile the undisturbed Earth's magnetic field represents a fundamental information source for orientation purposes, magnetic distortions have been mostly considered as a source of error. However, when distortions are temporally stable and spatially distinctive, they could provide a unique magnetic landscape that can be used in different applications, from indoor localization to sensor fusion algorithms for attitude estimation. The main purpose of this work, therefore, is to present a method to characterize the 3D magnetic vector in every point of the measurement volume.
View Article and Find Full Text PDFCanonical Correlation Analysis (CCA) is an increasingly used approach in the field of Steady-State Visually Evoked Potential (SSVEP) recognition. The efficacy of the method has been widely proven, and several variations have been proposed. However, most CCA variations tend to complicate the method, usually requiring additional user training or increasing computational load.
View Article and Find Full Text PDFBackground And Objective: Transcranial direct current stimulation (tDCS) and neurofeedback-guided motor imagery (MI) have attracted considerable interest in neurorehabilitation, given their ability to influence neuroplasticity. As tDCS has been shown to modulate event-related desynchronization (ERD), the neural signature of motor imagery detected for neurofeedback, a combination of the techniques was recently proposed. One limitation of this approach is that the area targeted for stimulation is the same from which the signal for neurofeedback is acquired.
View Article and Find Full Text PDFThe aims of the present study were the instrumental validation of inertial-magnetic measurements units (IMMUs) in water, and the description of their use in clinical and sports aquatic applications applying customized 3D multi-body models. Firstly, several tests were performed to map the magnetic field in the swimming pool and to identify the best volume for experimental test acquisition with a mean dynamic orientation error lower than 5°. Successively, the gait and the swimming analyses were explored in terms of spatiotemporal and joint kinematics variables.
View Article and Find Full Text PDFComput Intell Neurosci
February 2017
Motor imagery is a common control strategy in EEG-based brain-computer interfaces (BCIs). However, voluntary control of sensorimotor (SMR) rhythms by imagining a movement can be skilful and unintuitive and usually requires a varying amount of user training. To boost the training process, a whole class of BCI systems have been proposed, providing feedback as early as possible while continuously adapting the underlying classifier model.
View Article and Find Full Text PDFOne of the major concerns of recent studies is the correct discrimination between vegetative and minimally conscious state as the distinction between these two conditions has major implications for subsequent patient rehabilitation. In particular, it would be advantageous to establish communication with these patients. This work describes a procedure using EEG to detect brain responses to imagery instruction in patients with disorders of consciousness.
View Article and Find Full Text PDF