Background: Among no-touch automatized disinfection devices, UV-C radiation proved to be one of the most effective against a broad-spectrum of microorganisms causing healthcare-associated infections.
Aim: To evaluate the antimicrobial efficacy of an experimental UV-C robotic platform, under controlled conditions and in a real hospital scenario, when used to implement the Standard cleaning Operating Protocol (SOP).
Methods: In vitro, after dose calibration tests, bactericidal and virucidal efficacy was tested according to the ASTM E3135-18.
The role of microplastics (MPs) in the spread of antibiotic resistance genes (ARGs) is increasingly attracting global research attention due to their unique ecological and environmental effects. The ubiquitous use of plastics and their release into the environment by anthropic/industrial activities are the main sources for MP contamination, especially of water bodies. Because of their physical and chemical characteristics, MPs represent an ideal substrate for microbial colonization and formation of biofilm, where horizontal gene transfer is facilitated.
View Article and Find Full Text PDFImproving the cleaning and disinfection of high-touch surfaces is one of the core components of reducing healthcare-associated infections. The effectiveness of an enhanced protocol applying UV-C irradiation for terminal room disinfection between two successive patients was evaluated. Twenty high-touch surfaces in different critical areas were sampled according to ISO 14698-1, both immediately pre- and post-cleaning and disinfection standard operating protocol (SOP) and after UV-C disinfection (160 sampling sites in each condition, 480 in total).
View Article and Find Full Text PDFA viral spread occurrence such as the SARS-CoV-2 pandemic has prompted the evaluation of different disinfectants suitable for a wide range of environmental matrices. Chlorine dioxide (ClO) represents one of the most-used virucidal agents in different settings effective against both enveloped and nonenveloped viruses. This narrative synthesis is focused on the effectiveness of ClO applied in healthcare and community settings in order to eliminate respiratory transmitted, enteric, and bloodborne viruses.
View Article and Find Full Text PDFFailure in the reprocessing of thermolabile flexible endoscopes has been reported as one of the most important threats to patient health. A case report and observational study was conducted, from August 2014 to December 2019, in the Digestive Endoscopy Unit of a University Hospital in Italy, where two cases of Klebsiella pneumoniae carbapenemase ()-producing infections in patients undergoing endoscopic retrograde cholangio-pancreatography were observed. Following the risk/safety management practices, an epidemiological investigation was started, duodenoscopes were removed from use and the reprocessing practices reviewed.
View Article and Find Full Text PDFMicrobiological surveillance carried out in order to verify the effectiveness of endoscope reprocessing does not include the research of viruses, although endoscopes may be associated with the transmission of viral infections. This paper reports the experience of the University Hospital of Pisa in managing the risk from severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) during an endoscopy. A review of the reprocessing procedure was conducted to assess whether improvement actions were needed.
View Article and Find Full Text PDFInt J Environ Res Public Health
September 2020
Despite an increase of literature data on spp. presence in private water systems, epidemiological reports assert a continuing high incidence of Legionnaires' disease infection in Italy. In this study, we report a survey on spp.
View Article and Find Full Text PDFInternational literature data report that the increase of infectious risk may be due to heating, ventilation and air conditioning (HVAC) systems contaminated by airborne pathogens. Moreover, the presence of complex rotating dehumidification wheels (RDWs) may complicate the cleaning and disinfection procedures of the HVAC systems. We evaluated the efficacy of a disinfection strategy applied to the RDW of two hospitals' HVAC systems.
View Article and Find Full Text PDFHigh-touch surfaces cleaning and disinfection require the adoption of effective and proper executed protocols, especially during carbapenem-resistant (CRAB) endemo-epidemic situations. We evaluated the effectiveness and residual disinfectant activity of disposable pre-impregnated wipes (Modified Operative Protocol, MOP) in reducing environmental bioburden versus a two-step Standard Operative Protocol (SOP) in a 12-bed Intensive Care Unit. Five high-touch surfaces were cleaned and disinfected either according to the SOP (alcohol-based cleaning and chlorine-based disinfection) or using quaternary ammonium compounds-based disposable wipes (MOP).
View Article and Find Full Text PDFInt J Environ Res Public Health
October 2017
Although the European reports highlight an increase in community-acquired Legionnaires' disease cases, the risk of spp. in private houses is underestimated. In Pisa (Italy) we performed a three-year survey on Legionella presence in 121 buildings with an independent hot water production (IB); 64 buildings with a central hot water production (CB); and 35 buildings with a solar thermal system for hot water production (TB).
View Article and Find Full Text PDFObjectives: To evaluate the effectiveness of hydrogen peroxide (HP) use as a disinfectant in the hospital water network for the control of spp. colonization.
Methods: Following the detection of high levels of contamination in a 136-bed general hospital water network, an HP treatment of the hot water supply (25 mg/L) was adopted.
Background: Surgical site infection (SSI) is one of the most frequent health care-associated infections. One of the practices to reduce their incidence is preoperative skin antisepsis. Two of the most commonly active components used are chlorhexidine gluconate and povidone iodine.
View Article and Find Full Text PDF