Publications by authors named "Anjan Sinha"

Background And Aims: Femoral artery access is widely used despite recent increase in radial access for percutaneous coronary interventions (PCI). Femoral artery closure devices are used to shorten vascular closure time and reduce bleeding. We sought to examine sex-based outcomes of femoral artery vascular closure devices (VCD) in patients undergoing PCI.

View Article and Find Full Text PDF
Article Synopsis
  • A 78-year-old woman experienced severe degeneration of her bioprosthetic mitral valve and had a successful transcatheter mitral valve replacement using a valve-in-valve technique.
  • After the procedure, she developed cardiogenic shock due to perforation of the left ventricle.
  • This case highlights the need for careful evaluation and management of patients after transcatheter valvular procedures to avoid complications.
View Article and Find Full Text PDF

Background: Patients with severe aortic stenosis (AS) and left ventricular (LV) dysfunction demonstrate improvement in left ventricular injection fraction (LVEF) after aortic valve replacement (AVR). The timing and magnitude of recovery in patients with very low LVEF (≤ 25%) in surgical or transcatheter AVR is not well studied.

Objective: Determine clinical outcomes following transcatheter aortic valve replacement (TAVR) and surgical aortic valve repair (SAVR) in the subset of patients with severely reduced EF ≤ 25%.

View Article and Find Full Text PDF

Unfractionated heparin is the most common anticoagulant used during percutaneous coronary intervention. Practice guidelines recommend an initial weight-based heparin bolus dose between 70 and 100 U/kg to achieve target activated clotting time (ACT) of 250-300 seconds. The impact of severe obesity on weight-based heparin dosing is not well studied.

View Article and Find Full Text PDF

Background: Femoral arterial access remains widely used despite recent increase in radial access for cardiac catheterization and percutaneous coronary intervention (PCI). Various femoral artery closure devices have been developed and are commonly used to shorten vascular closure times, with variable rates of vascular complications observed in clinical trials. We sought to examine the rates of contemporary outcomes during diagnostic catheterization and PCI with the most common femoral artery closure devices.

View Article and Find Full Text PDF

We describe a unique case of fulminant myocarditis in a patient with presumed SARS-CoV-2 reinfection. Patient had initial infection 4 months backand had COVID-19 antibody at the time of presentation. Endomyocardial biopsy showed lymphocytic myocarditis, that is usually seen in viral myocarditis.

View Article and Find Full Text PDF

Background: High plasma fibrin clot strength (MA) measured by thrombelastography (TEG) is associated with increased risk of cardiac events after percutaneous coronary interventions (PCIs). Factor XIIIa (FXIIIa) cross-links soluble fibrin, shortens clot formation time (TEG-K), and increases final clot strength (MA).

Methods: We analyzed platelet-poor plasma from patients with previous PCI.

View Article and Find Full Text PDF

Background: Reloading with high-dose atorvastatin shortly before percutaneous coronary interventions (PCIs) has been proposed as a strategy to reduce periprocedural myonecrosis. There has been a concern that statins that are metabolized by cytochrome P450 3A4 may interfere with clopidogrel metabolism at high doses. The impact of simultaneous administration of high doses of atorvastatin and clopidogrel on the efficacy of platelet inhibition has not been established.

View Article and Find Full Text PDF

Background: Inaccurate aortic valve sizing and selection is linked to paravalvular leakage in transcatheter aortic valve replacement (TAVR). Here, a novel sizing valvuloplasty conductance balloon (SVCB) catheter is shown to be accurate, reproducible, unbiased, and provides real-time tool for aortic valve sizing that fits within the standard valvuloplasty procedure.

Methods And Results: The SVCB catheter is a valvuloplasty device that uses real-time electrical conductance measurements based on Ohm's Law to size the balloon opposed against the aortic valve at any given inflation pressure.

View Article and Find Full Text PDF

Factor XIII (FXIII) is necessary for cross linking of fibrin strands and generation of stable fibrin clot. FXIII Val34Leu is a common genetic single nucleotide polymorphism that has been associated with accelerated fibrin stabilization and reduced rate of fibrinolysis. The contribution of Val34Leu to long term risk of recurrent myocardial infarction (MI) in patients with coronary stenting has not been conclusively established.

View Article and Find Full Text PDF

Background: Because stent underdeployment occurs frequently, accurate minimal stent area (MSA) measurement during postdilatation is necessary. This study investigated the accuracy and repeatability for MSA determination using a novel conductance balloon (CB) catheter for peripheral vessels.

Methods: The CB catheter is a standard balloon catheter that measures electrical conductance (ratio of current/voltage drop) in real-time during inflation, which directly relates to the balloon cross-sectional area through Ohm's law.

View Article and Find Full Text PDF

Objectives: Ideally, guidewires used during peripheral vasculature (PV) interventions could serve both as a therapy delivery platform and a diagnostic tool for real-time vessel sizing (2-in-1 function).

Background: Vascular imaging modalities, like intravascular ultrasound (IVUS), used during lower PV interventions, can improve outcomes versus angiographic assessment alone, but are rarely used due to added time, cost, and required clinical training/interpretation.

Methods: A 0.

View Article and Find Full Text PDF

Inflammation is implicated in the progression of coronary artery disease and the molecular processes of inflammation and thrombosis are closely intertwined. Elevated levels of C-reactive protein (CRP) have been associated with an elevated risk of adverse ischaemic events after coronary stenting and hypercoagulability. Heightened whole blood clot strength measured by thrombelastography (TEG) has been associated with adverse ischaemic events after stenting.

View Article and Find Full Text PDF

Introduction: Clopidogrel inhibits ADP mediated platelet aggregation through inhibition of the P2Y12 receptor by its active metabolite. Thrombin induces platelet aggregation by binding to protease activated receptor-1 (PAR-1), and inhibition of PAR-1 has been evaluated in patients treated with clopidogrel to reduce ischemic events after acute coronary syndromes. Residual PAR-1 mediated platelet aggregation may be dependent on extent of clopidogrel response.

View Article and Find Full Text PDF

Stent can cause flow disturbances on the endothelium and compliance mismatch and increased stress on the vessel wall. These effects can cause low wall shear stress (WSS), high wall shear stress gradient (WSSG), oscillatory shear index (OSI), and circumferential wall stress (CWS), which may promote neointimal hyperplasia (IH). The hypothesis is that stent-induced abnormal fluid and solid mechanics contribute to IH.

View Article and Find Full Text PDF

Background: External pumps have been previously used to minimize edema and hemorrhage caused by coronary retroperfusion. The objective of this study was to use a pump-less approach (selective autoretroperfusion, SARP) to preserve myocardial function after acute coronary artery ligation.

Methods: In five experimental pigs, the LAD artery was ligated distal to the first diagonal and retroperfusion was instituted for three hours from a brachiocephalic artery at 50 mmHg pressure through an adjustable occluder on the cannula.

View Article and Find Full Text PDF

Objectives: The objective of this human pilot study was to determine the safety and the level of agreement between a novel nonimaging 2.7 Fr. catheter-based system (LumenRECON, LR) that uses electrical conductance for measurement of lumen cross-sectional area (CSA) with intravascular ultrasound (IVUS) and quantitative coronary angiography (QCA).

View Article and Find Full Text PDF

Electrocardiographic signs of a non-ST elevation myocardial infarction (NSTEMI) are nonspecific, and therefore the diagnosis of NSTEMI during acute coronary syndromes (ACS) depends mainly on cardiac biomarker levels. Fragmented QRS (fQRS) represents myocardial conduction abnormalities due to myocardial infarction (MI) scars in patients with coronary artery disease. However, the time of appearance of fQRS during ACS has not been investigated.

View Article and Find Full Text PDF

Accurate sizing of vessel diameter is important for understanding the physiology of blood vessels as well as the treatment of coronary and peripheral artery disease. The objective of this study was to validate a novel catheter-based system [the LumenRECON (LR) system] for the real-time reconstruction of lumen cross-sectional area (CSA) along the length of a vessel segment. A total of 22 swine (20 Yorkshire and 2 atherosclerotic Ossabaw swine) were used to evaluate the accuracy, reproducibility, and safety of the system compared with intravascular ultrasound (IVUS).

View Article and Find Full Text PDF

Stent sizing and apposition have been shown to be important determinants of clinical outcome. This study evaluates the mechanical effects of undersizing and oversizing of stents on endothelial wall shear stress (WSS) and vessel wall stress to determine a possible biomechanical mechanism of in-stent restenosis and thrombosis. Three-dimensional computational models of stents, artery, and internal fluid were created in a computer-assisted design package, meshed, and solved in finite element and computational fluid dynamic packages.

View Article and Find Full Text PDF

The compliance of the vessel wall affects hemodynamic parameters which may alter the permeability of the vessel wall. Based on experimental measurements, the present study established a finite element (FE) model in the proximal elastic vessel segments of epicardial right coronary arterial (RCA) tree obtained from computed tomography. The motion of elastic vessel wall was measured by an impedance catheter and the inlet boundary condition was measured by an ultrasound flow probe.

View Article and Find Full Text PDF

We report the case of a 32-year-old man who presented at the emergency department with severe chest pressure, left arm pain, and dizziness. These symptoms were described as intermittent, occurring after exercise and at rest. He had undergone several stress tests during the past 8 years, but no objective evidence of ischemia was produced.

View Article and Find Full Text PDF