J Cardiovasc Magn Reson
October 2012
Background: The objective of this study was the quantification of myocardial motion from 3D tissue phase mapped (TPM) CMR. Recent work on myocardial motion quantification by TPM has been focussed on multi-slice 2D acquisitions thus excluding motion information from large regions of the left ventricle. Volumetric motion assessment appears an important next step towards the understanding of the volumetric myocardial motion and hence may further improve diagnosis and treatments in patients with myocardial motion abnormalities.
View Article and Find Full Text PDFObject: Until now, a three-directional velocity field has mostly been obtained by velocity encoding in three directions, which is very time-consuming and hence not usually used in clinical routine. We show the feasibility of combining in-plane tagging with through-plane tissue phase mapping (TPM) to encode a three-directional velocity field at 3 T with reduced overall acquisition time.
Materials And Methods: Assessment of a three-directional velocity field was performed for 10 healthy volunteers.
J Cardiovasc Magn Reson
October 2011
Background: The objective of this study was to investigate the impact of sensitivity encoding on the quantitative assessment of cardiac motion in black blood cine tissue phase mapping (TPM) sequences. Up to now whole volume coverage of the heart is still limited by the long acquisition times. Therefore, a significant increase in imaging speed without deterioration of quantitative motion information is indispensable.
View Article and Find Full Text PDFObject: The objective was to improve the temporal resolution in black-blood CINE tissue phase mapping sequences at high field MR systems. The temporal resolution is limited due to SAR constraints causing idle times into the sequence. The aim was to avoid these idle times and therefore providing an increased number of heart phases.
View Article and Find Full Text PDFBackground: The assessment of myocardial motion with tissue phase mapping (TPM) provides high spatiotemporal resolution and quantitative motion information in three directions. Today, whole volume coverage of the heart by TPM encoding at high spatial and temporal resolution is limited by long data acquisition times. Therefore, a significant increase in imaging speed without deterioration of the quantitative motion information is required.
View Article and Find Full Text PDFObjective: To investigate the feasibility of MRI for non-invasive assessment of the coronary sinus (CS) and the number and course of its major tributaries in heart failure patients.
Methods: Fourteen non-ischaemic heart failure patients scheduled for cardiac resynchronisation therapy (CRT) underwent additional whole-heart coronary venography. MRI was performed 1 day before device implantation.