Blue diode lasers are alternative curing devices for dental composites. The aim of this study was to investigate the influence of blue diode laser polymerization on shear bond strength of bulk fill composites to human dentin and temperature rise during two types of polymerization. Composite cylinders of SDR Plus(SDR) and Ever X Flow(EX) were bonded to dentin slabs using Adhese Universal and curing devices blue diode laser (449 nm, 1.
View Article and Find Full Text PDFObjective: To evaluate the 5-year clinical performance of a glass hybrid restorative system and a nano-hybrid resin composite in moderate to large two-surface class II cavities.
Materials And Methods: This study was carried out by dental schools in Zagreb, Croatia; Izmir, Turkey; Belgrade, Serbia; and Milan, Italy. A total of 180 patients requiring two class-II two-surface restorations in the molars of the same jaw were recruited.
This study sought to evaluate the efficacy of SWEEPS in the removal of epoxy-resin-based and calcium-silicate-containing endodontic sealer combined with single-cone and carrier-based obturation techniques through a micro-CT analysis. Seventy-six single-rooted extracted human teeth with single root canal were instrumented with Reciproc instruments. Specimens were randomly divided into four groups (n = 19) according to the root canal filling material and obturation technique: (1) AH Plus sealer + Reciproc gutta-percha, (2) TotalFill BC sealer + TotalFill BC Points, (3) AH Plus sealer + Guttafusion obturator, and (4) MTA Fillapex + Guttafusion obturator.
View Article and Find Full Text PDFThe objective of this study was to evaluate the efficacy of reciprocating instruments in the removal of bioceramic and epoxy resin-based sealers using micro-CT analysis. Root canals of 40 extracted human teeth were instrumented with a size R25 Reciproc instrument. Specimens were randomly divided into two groups (n = 20) according to the root canal filling material.
View Article and Find Full Text PDFThe aim of this research was to investigate the compressive strength (CS), breaking strength (BS), and compressive modulus (CM) of conventional glass ionomer cement (GIC) modified with TiO nano particles, marine-derived hydroxyapatite (md-HAp) microparticles (<45 µm), and a combination of TiO NP and md-HAp particles. The materials used in the study were conventional GIC Fuji IX GP Extra (GC Corporation, Tokyo, Japan), TiO powder P25 (Degussa, Essen, Germany), and HAp synthesized from cuttlefish bone and ground in a mortar to obtain md-HAp powder. md-HAp was characterized using FTIR and SEM analysis.
View Article and Find Full Text PDFThis ex vivo study aimed to compare the microtensile bond strength of fiber-reinforced and particulate filler composite to coronal and pulp chamber floor dentin using a self-etching adhesive system. Coronal dentin of 40 human molar teeth was exposed by cutting occlusal enamel with a low-speed saw. Teeth were then randomly divided into two groups (n = 20).
View Article and Find Full Text PDFThe use of lasers for treatment of oral leukoplakia has gained a lot of interest in the past years, however, data on the use of Er:YAG laser are scarce. The aim of this study was to compare the efficacy of Er:YAG laser and 1% topical isotretinoin in the treatment of 27 oral leukoplakia patients. Er:YAG laser (LightWalker AT, Fotona, Slovenia) was used in 27 patients with 27 leukoplakia lesions.
View Article and Find Full Text PDFPurpose: To compare the clinical performance of a glass hybrid restorative system, EQUIA Forte, with that of a nanohybrid resin composite, Tetric EvoCeram, in two-surface class II cavities.
Materials And Methods: This multicenter, randomized controlled clinical study was conducted at four different dental schools. In total, 360 restorations were placed in patients in need of two class-II, two-surface restorations in the molar region of the same jaw.
Purpose: To investigate the micro push-out bond strength of individually formed (everStick Post) and prefabricated (GC Fiber Post) fiber-reinforced composite (FRC) posts cemented with three different types of self-adhesive composite cements.
Materials And Methods: Forty-two single-rooted human teeth were decoronated, endodontically treated, and had post spaces prepared for everStick Post (n = 21) or GC Fiber Post (n = 21). The teeth were randomly divided into three subgroups (n = 7), and posts were cemented either with G-CEM LinkAce (GC), SpeedCEM (Ivoclar Vivadent) or RelyX U200 (3M Oral Care).
The purposes of the study were to evaluate the bond strength of bioceramic TotalFill root repair material (RRM) in retrograde cavities prepared using Er:YAG and Er,Cr:YSGG laser and steel bur, and to analyze failure modes. The root canals of 30 single-rooted teeth were endodontically treated, their root-ends were resected using a diamond bur, and the teeth were randomly divided into three groups (N = 10) according to the retrograde cavity preparation technique: (1) Er:YAG laser, (2) Er,Cr:YSGG laser, and (3) steel bur. All retrograde cavities were filled with the TotalFill RRM which was prepared according to the manufacturers' instructions.
View Article and Find Full Text PDFThe aim of this in vitro study was to evaluate cytotoxicity and genotoxicity of six different dental nanocomposite materials, three conventional ones and three flowable composite resin materials, in human lymphocytes. The following materials were tested: Tetric EvoCeram, Tetric EvoFlow, Filtek Ultimate, Filtek Ultimate Flow, G-aenial and G-aenial Flo. Cytotoxicity was evaluated for two mass concentrations (0.
View Article and Find Full Text PDFStatement Of Problem: Data on the retention of individually formed fiber-reinforced composite posts (everStick) cemented with self-adhesive cement are lacking.
Purpose: The purpose of this in vitro study was to investigate the pull-out strength of 2 different fiber-reinforced composite posts (prefabricated and individually formed) cemented into extracted teeth with self-adhesive resin cement.
Material And Methods: Thirty extracted single-rooted human teeth were decoronated, endodontically treated, and prepared with post spaces of equal length.
Objective: The aim of this study was to evaluate the bond strength of three calcium silicate-based root-end filling materials.
Materials And Methods: The root canals of 30 single-rooted teeth were endodontically treated; their root ends were resected and root-end cavities were prepared using ultrasonic tip. The teeth were randomly divided into three groups according to the material: (1) Micro-Mega mineral trioxide aggregate (MM-MTA), (2) Biodentine, and (3) TotalFill root repair material (RRM).
Objective: Ishemic bone disease has multifactorial etiologies. Cronic dental infections should be eliminated to prevent osteonecrosis of the jaw.
Case Report: We report an unusual case of osteonecrosis due to the pulpal-peridontal syndrome and subsequent pulp necrosis.
Objective: The objective was to compare the efficacy of three different lasers in disinfection of root canals inoculated with Enterococcus faecalis and Candida albicans biofilms.
Background: Endodontic space disinfection depends on the type of root canal irrigant used and the way it is delivered and agitated because irrigants have limited ability to reach all parts of root canal system.
Materials And Methods: Thirty single-rooted human teeth were selected.
Objective: The aim of this study was to investigate the effect of laser activated irrigation (LAI) using two erbium lasers on bond strength of individually formed fiber-reinforced composite (FRC) posts to root canal dentin.
Materials And Methods: Twenty-seven single-rooted human teeth were endodontically treated and after post space preparation divided into three groups (n=9 per group), according to the pre-treatment of post space preparation: 1) Conventional syringe irrigation (CSI) and saline; 2) Er.YAG photon-induced photoacoustic streaming (PIPS) technique and saline; 3) Er,Cr:YSGG activated irrigation with RFT2 tip.
The primary function of an endodontic post is to provide retention for the core and enable full sealing of the coronal portion of the root canal. Traditionally used metal posts do not meet the requirements of modern dental medicine due to some fairly significant drawbacks such as color, corrosion potential, non-adhesive bonding and high modulus of elasticity which can lead to root fracture. Recently, esthetic ceramic and fiber reinforced posts have been manufactured in order to avoid such imperfections.
View Article and Find Full Text PDFObjective: The aim of this study was to investigate the cytotoxicity of two different bioactive root canal sealers: one based on mineral trioxide aggregate, MTA Fillapex (Angelus, Solucoes Odontologicas, Londrina, PR, Brazil), and the other based on bioceramics, Endosequence BC Sealer (Brasseler, Savannah, Georgia, USA), in culture of mouse L929 fibroblasts.
Materials And Methods: Mouse fibroblasts (L929), obtained from subcutaneous connective tissue of mouse line C3Hf, were cultivated in plastic culture flasks in an incubator at 37şC, with 5% CO2 and 90% humidity. Freshly mixed Endosequence BC Sealer and MTA Fillapex (0.
Objectives: The aim of this study was to evaluate the effect of photon induced photoacoustic streaming (PIPS) technique in combination with EDTA on bond strength of gutta-percha/AH Plus and Resilon/RealSeal SE root canal fillings to root dentine.
Materials And Methods: Forty freshly extracted human maxillary anterior teeth with intact straight roots, were instrumented endodontically with rotating ProTaper instruments and randomly divided into two experimental groups. In group 1 (n = 20), root canals were rinsed for 1 minute with 2 ml of 17% EDTA.
Objective: The primary objective of this study was to compare the dentin ablation volume and ablation rate of quantum square pulse (QSP), using two different pulse energy settings plus a new digitally controlled dental laser handpiece (X-Runner), with those of variable square pulse (VSP), using three different pulse durations. The secondary objective was to examine, by scanning electron microscopy (SEM), the surface effects of ablation with the different Er:YAG laser modes on the dentin surfaces.
Background Data: The available literature has limited data on the efficiency of different operating modes, pulse durations, and the new digitally controlled handpiece of the Er:YAG laser on human dentin.
The purpose of this in vitro study was to evaluate the microtensile bond strength of one-step self-etch adhesive to human dentin surface modified with air abrasion and sonic technique and to assess the morphological characteristics of the pretreated dentin surface. The occlusal enamel was removed to obtain a flat dentin surface for thirty-six human molar teeth. The teeth were randomly divided into three experimental groups (n = 12 per group), according to the pretreatment of the dentin: (1) control group, (2) air abrasion group, and (3) sonic preparation group.
View Article and Find Full Text PDFThe aim of this study was to examine and compare vertical forces exerted during root canal obturation with the cold lateral condensation technique, Thermafil technique and ProTaper guttapercha. Fourty-five single-rooted permanent teeth were used in the study. All specimens were instrumented using the ProTaper rotating technique and were randomly divided into three experimental groups (n = 15 per group).
View Article and Find Full Text PDFThe purpose of this in vitro study was to evaluate microleakage along glass-fibre posts cemented with three different cements after cyclic loading. After post-space preparation, fifty obturated root canals were randomly divided into three experimental groups and two control groups. In group 1, Glassix posts were cemented using Harvard cement, in group 2, Fuji PLUS cement was used and in group 3, Variolink II was used for post cementation.
View Article and Find Full Text PDFObjective: The aim of the study was to evaluate the microtensile bond strength of a composite resin to dentin modified with three different pulse durations of the Er:YAG laser based on variable square pulse technology and with one self-etch adhesive.
Materials And Methods: The entire occlusal enamel was removed to obtain flat dentin surface for 48 human molar teeth. The teeth were randomly divided into four experimental groups (n=12 per group), according to the pretreatment of dentin: (1) control group; (2) super short pulse (SSP) (50 μsec); (3) medium short pulse (MSP) (100 μsec); and (4) short pulse (SP) (300 μsec) with Er:YAG laser.