CHL1 is a close homolog of L1, a cell adhesion molecule that plays major roles in neural and tumor cell functions. We had found that young adult female mice deficient in CHL1 recovered better than their wild-type female littermates after thoracic Spinal Cord Injury (SCI). This observation was surprising, because CHL1 increases neurite outgrowth in vitro.
View Article and Find Full Text PDFAutofluorescence of blood has been explored as a label free approach for detection of cell types, as well as for diagnosis and detection of infection, cancer, and other diseases. Although blood autofluorescence is used to indicate the presence of several physiological abnormalities with high sensitivity, it often lacks disease specificity due to use of a limited number of fluorophores in the detection of several abnormal conditions. In addition, the measurement of autofluorescence is sensitive to the type of sample, sample preparation, and spectroscopy method used for the measurement.
View Article and Find Full Text PDFHigh-powered pulsed electric fields (PEF) may be used for tissue debridement and disinfection, while lower PEF intensities may stimulate beneficial cellular responses for wound healing. We investigated the dual effects of nonuniform PEF on cellular death and stimulation. Dermal fibroblast or keratinocyte monolayers were exposed to PEF induced by two needle electrodes (2 mm apart).
View Article and Find Full Text PDFMild traumatic brain injury (mTBI) is a frequently overlooked public health concern that is difficult to diagnose and treat. Diffuse axonal injury (DAI) is a common mTBI neuropathology in which axonal shearing and stretching induces breakdown of the cytoskeleton, impaired axonal trafficking, axonal degeneration, and cognitive dysfunction. DAI is becoming recognized as a principal neuropathology of mTBI with supporting evidence from animal model, human pathology, and neuroimaging studies.
View Article and Find Full Text PDFFlow cytometry is an invaluable tool utilized in modern biomedical research and clinical applications requiring high throughput, high resolution particle analysis for cytometric characterization and/or sorting of cells and particles as well as for analyzing results from immunocytometric assays. In recent years, research has focused on developing microfluidic flow cytometers with the motivation of creating smaller, less expensive, simpler, and more autonomous alternatives to conventional flow cytometers. These devices could ideally be highly portable, easy to operate without extensive user training, and utilized for research purposes and/or point-of-care diagnostics especially in limited resource facilities or locations requiring on-site analyses.
View Article and Find Full Text PDFTo create musculoskeletal tissue scaffolds for functional integration into host tissue, myotubes must be properly aligned with native tissue and spur the formation of neuromuscular junctions. However, our understanding of myoblast differentiation in response to structural alignment is incomplete. To examine how substrate anisotropy mediates myotube differentiation, we studied C2C12 myoblasts grown on aligned collagen substrates in the presence or absence of agrin.
View Article and Find Full Text PDFTraumatic brain injury (TBI) affects 5.3 million people in the United States, and there are 12,500 new cases of spinal cord injury (SCI) every year. There is yet a significant need for in vitro models of TBI and SCI in order to understand the biological mechanisms underlying central nervous system (CNS) injury and to identify and test therapeutics to aid in recovery from neuronal injuries.
View Article and Find Full Text PDFPreclinical testing in rodent models is a ubiquitous part of modern biomedical research and commonly involves accessing the venous bloodstream for blood sampling and drug delivery. Manual tail vein cannulation is a time-consuming process and requires significant skill and training, particularly since improperly inserted needles can affect the experimental results and study outcomes. In this paper, we present a miniaturized, robotic medical device for automated, image-guided tail vein cannulations in rodent models.
View Article and Find Full Text PDFToxicol Appl Pharmacol
December 2017
The failure of drug candidates during clinical trials and post-marketing withdrawal due to Drug Induced Liver Injury (DILI), results in significant late-stage attrition in the pharmaceutical industry. Animal studies have proven insufficient to definitively predict DILI in the clinic, therefore a variety of in vitro models are being tested in an effort to improve prediction of human hepatotoxicity. The model system described here consists of cryopreserved primary rat, dog or human hepatocytes co-cultured together with a fibroblast cell line, which aids in the hepatocytes' maintenance of more in vivo-like characteristics compared to traditional hepatic mono-cultures, including long term viability and retention of activity of cytochrome P450 isozymes.
View Article and Find Full Text PDFHepatitis B virus causes chronic infections in 250 million people worldwide. Chronic hepatitis B virus carriers are at risk of developing fibrosis, cirrhosis, and hepatocellular carcinoma. A prophylactic vaccine exists and currently available antivirals can suppress but rarely cure chronic infections.
View Article and Find Full Text PDFIn this study, a new 3D liver model was developed using biomimetic nanofiber scaffolds and co-culture system consisting of hepatocytes and fibroblasts for the maintenance of long-term liver functions. The chitosan nanofiber scaffolds were fabricated by the electrospinning technique. To enhance cellular adhesion and spreading, the surfaces of the chitosan scaffolds were coated with fibronectin (FN) by adsorption and evaluated for various cell types.
View Article and Find Full Text PDFSubstrate and cell patterning techniques are widely used in cell biology to study cell-to-cell and cell-to-substrate interactions. Conventional patterning techniques work well only with simple shapes, small areas and selected bio-materials. This article describes a method to distribute cell suspensions as well as substrate solutions into complex, long, closed (dead-end) polydimethylsiloxane (PDMS) microchannels using negative pressure.
View Article and Find Full Text PDFSubstrate and cell patterning are widely used techniques in cell biology to study cell-to-cell and cell-substrate interactions. Conventional patterning techniques work well only with simple shapes, small areas and selected bio-materials. This paper describes a method to distribute cell suspensions as well as substrate solutions into complex, long, closed (dead-end) polydimethylsiloxane (PDMS) microchannels using negative pressure.
View Article and Find Full Text PDFThis paper introduces a benchtop method for patterning mammalian cells-i.e., for culturing cells at specific locations-on planar substrates.
View Article and Find Full Text PDF