Background: The NTCP methodology evaluating side-effects (S-Es) was initially used in radiotherapy (RT), and later was extended to brachytherapy (BT). The NTCP0 methodology has been recently introduced in RT. Given the advantages, this methodology could replace NTCP.
View Article and Find Full Text PDFPurpose: To encourage the use of the NTCP0 for evaluating safety as a new alternative of assessing the S-Es of the radiation oncology treatments; and the use of the 'NTCP0cal' methodology that calculates/estimates NTCP0.
Method: Revisions of studies related to use of the NTCP in the evaluations of S-Es. Development of the first version of the Matlab application of our methodology, which provides three options, two of them employ the well-known aspects of a phenomenological model, or the relationship with the TNTCP; where NTCP0 = 100%-TNTCP; and the third option determines NTCP0 from an assumed NTCP discrete probabilistic distribution from the binomial distribution, where one of its parameters is automatically defined from a databased of the Disease locations Vs.
This study proposes phenomenological models for total normal tissue complication probability (TNTCP) and NTCP0. NTCP0 is a new acronym for reformulating the current complication-free cure (P+) and uncomplicated tumor control probability (UTCP) concepts, and TNTCP will reformulate the current NTCP involving multiple organs at risks. The current probabilistic concepts are incoherently formulated with mathematical operations of tumor control probability (TCP) and normal tissue complication probability (NTCP) that are associated with different stochastic processes and random variables.
View Article and Find Full Text PDFAsian Pac J Cancer Prev
August 2019
Objective: The present study aims to evaluate the accelerated intensity modulated radiotherapy (IMRT) of head and neck (HandN) treatments using physical indices and radiobiological models with its clinical correlation using histogram analysis in radiation therapy (HART). The radiobiological evaluation in terms of tumor control probability (TCP) and normal tissue complication probability (NTCP) indices were compared with acute toxicity. Materials and Methods: A total of twenty patients with stage III and IV of HandN cases treated with accelerated IMRT using 6MV photons were chosen for the study.
View Article and Find Full Text PDFRadiotherapy (RT) treatment planning systems (TPS) are designed for the fast calculation of dose to the tumor bed and nearby organs at risk using x-ray computed tomography (CT) images. However, CT images for a patient are typically available for only a small portion of the body, and in some cases, such as for retrospective epidemiological studies, no images may be available at all. When dose to organs that lie out-of-scan must be estimated, a convenient alternative for the unknown patient anatomy is to use a matching whole-body computational phantom as a surrogate.
View Article and Find Full Text PDFIntroduction: The gamma analysis used for quality assurance of a complex radiotherapy plan examines the dosimetric equivalence between planned and measured dose distributions within some tolerance. This study explores whether the dosimetric difference is correlated with any radiobiological difference between delivered and planned dose.
Methods: VMAT or IMRT plans optimized for 14 cancer patients were calculated and delivered to a QA device.
Organ dose estimation for retrospective epidemiological studies of late effects in radiotherapy patients involves two challenges: radiological images to represent patient anatomy are not usually available for patient cohorts who were treated years ago, and efficient dose reconstruction methods for large-scale patient cohorts are not well established. In the current study, we developed methods to reconstruct organ doses for radiotherapy patients by using a series of computational human phantoms coupled with a commercial treatment planning system (TPS) and a radiotherapy-dedicated Monte Carlo transport code, and performed illustrative dose calculations. First, we developed methods to convert the anatomy and organ contours of the pediatric and adult hybrid computational phantom series to Digital Imaging and Communications in Medicine (DICOM)-image and DICOM-structure files, respectively.
View Article and Find Full Text PDFJ Appl Clin Med Phys
January 2014
The authors compared the relative dosimetric merits of Gamma Knife (GK) and CyberKnife (CK) in 15 patients with 26 brain metastases. All patients were initially treated with the Leksell GK 4C. The same patients were used to generate comparative CK treatment plans.
View Article and Find Full Text PDFA Histogram Analysis in Radiation Therapy (HART) program was primarily developed to increase the efficiency and accuracy of dose-volume histogram (DVH) analysis of large quantities of patient data in radiation therapy research. The program was written in MATLAB to analyze patient plans exported from the treatment planning system (Pinnacle 3 ) in the American Association of Physicists in Medicine/Radiation Therapy Oncology Group (AAPM/RTOG) format. HART-computed DVH data was validated against manually extracted data from the planning system for five head and neck cancer patients treated with the intensity-modulated radiation therapy (IMRT) technique.
View Article and Find Full Text PDF