Comput Softw Big Sci
May 2024
Cryogenic phonon detectors with transition-edge sensors achieve the best sensitivity to sub-GeV/c dark matter interactions with nuclei in current direct detection experiments. In such devices, the temperature of the thermometer and the bias current in its readout circuit need careful optimization to achieve optimal detector performance. This task is not trivial and is typically done manually by an expert.
View Article and Find Full Text PDFCoherent elastic neutrino-nucleus scattering and low-mass dark matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear recoil peak at around 112 eV induced by neutron capture. The measurement was performed with a CaWO_{4} cryogenic detector from the NUCLEUS experiment exposed to a ^{252}Cf source placed in a compact moderator.
View Article and Find Full Text PDFThe CRESST experiment employs cryogenic calorimeters for the sensitive measurement of nuclear recoils induced by dark matter particles. The recorded signals need to undergo a careful cleaning process to avoid wrongly reconstructed recoil energies caused by pile-up and read-out artefacts. We frame this process as a time series classification task and propose to automate it with neural networks.
View Article and Find Full Text PDFCRESST is a leading direct detection sub-GeVc dark matter experiment. During its second phase, cryogenic bolometers were used to detect nuclear recoils off the CaWO target crystal nuclei. The previously established electromagnetic background model relies on Secular Equilibrium (SE) assumptions.
View Article and Find Full Text PDFEur Phys J C Part Fields
March 2022
The COSINUS (Cryogenic Observatory for SIgnatures seen in Next-generation Underground Searches) experiment aims at the detection of dark matter-induced recoils in sodium iodide (NaI) crystals operated as scintillating cryogenic calorimeters. The detection of both scintillation light and phonons allows performing an event-by-event signal to background discrimination, thus enhancing the sensitivity of the experiment. The choice of using NaI crystals is motivated by the goal of probing the long-standing DAMA/LIBRA results using the same target material.
View Article and Find Full Text PDFEur Phys J C Part Fields
October 2019
The CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) dark matter search experiment aims for the detection of dark matter particles via elastic scattering off nuclei in crystals. To understand the CRESST electromagnetic background due to the bulk contamination in the employed materials, a model based on Monte Carlo simulations was developed using the Geant4 simulation toolkit. The results of the simulation are applied to the TUM40 detector module of CRESST-II phase 2.
View Article and Find Full Text PDFThe usual assumption in direct dark matter searches is to consider only the spin-dependent or spin-independent scattering of dark matter particles. However, especially in models with light dark matter particles O(GeV/c^{2}), operators which carry additional powers of the momentum transfer q^{2} can become dominant. One such model based on asymmetric dark matter has been invoked to overcome discrepancies in helioseismology and an indication was found for a particle with a preferred mass of 3 GeV/c^{2} and a cross section of 10^{-37} cm^{2}.
View Article and Find Full Text PDFAlthough first hints of the existence of Dark Matter were observed by the Swiss astronomer Zwicky already in the 1930s, only in recent years has it become known that the universe, in fact, is dominated by particles whose nature is almost unknown and which have never been directly observed. Meanwhile, as the existence of these particles is postulated not only by astronomy, but also cosmology and theoretical particle physics, there is significant effort to detect them in a laboratory experiment and determine their physical properties. However, as the interaction rate between Dark Matter particles and ordinary matter is extremely low, detectors have to be extremely sensitive.
View Article and Find Full Text PDF