Introduction: Permanent His bundle pacing (HBP) is the most physiological pacing modality, and new implantation systems are now available. The aim of the present study was to describe and compare four different techniques to perform HBP.
Methods And Results: We included all consecutive patients who underwent a HBP attempt in our initial experience between June 2020 and May 2022.
Leadless pacemaker implantation (LPI) has fewer device complications and reduced chance of infection compared to conventional pacemakers. Dextrocardia with situs viscerum inversus (DC+SVI) is a rare condition, which seldom leads to cardiac complications. However, its presence poses a challenge to operators in cardiac procedures.
View Article and Find Full Text PDFThe underlying mechanisms and temporal course of complete heart block (CHB) after blunt cardiac injuries (BCIs) are poorly understood, and a systematic analysis of available data is lacking. In this systematic review, PubMed was searched for publications of reported cases of CHB-BCI analyzing clinical findings, electrocardiographic features, temporal course, and outcomes. Case reports on CHB-BCI were available for 50 patients, mainly secondary to traffic or sport accidents.
View Article and Find Full Text PDFVentricular fibrillation is typically the initial arrhythmia in commotio cordis following precordium impacts that occur within an electrically vulnerable period of the cardiac cycle. Conversely, complete heart block is very rare in this context, and its mechanism and temporal course are poorly understood. The presented case concerns a 12-year-old boy, athletic skier, who developed a transient complete heart block following commotio cordis.
View Article and Find Full Text PDFAnn Noninvasive Electrocardiol
March 2017
Complete left bundle branch block (LBBB) is established according to standard electrocardiographic criteria. However, functional LBBB may be rate-dependent or can perpetuate during tachycardia due to repetitive concealed retrograde penetration of impulses through the contralateral bundle "linking phenomenon." In this brief article, we present two patients with basal complete LBBB in whom ablating the right bundle unmasked the actual antegrade conduction capabilities of the left bundle.
View Article and Find Full Text PDFAnn Noninvasive Electrocardiol
July 2016
Intravenous adenosine is a short-acting blocker of the atrioventricular node that has been used to unmask subtle or latent preexcitation, and also to enable catheter ablation in selected patients with absent or intermittent preexcitation. Depending on the accessory pathway characteristics, intravenous adenosine may produce specific electrocardiographic changes highly suggestive of the preexcitation variant. Herein, we view different ECG responses to this pharmacological test in various preexcitation patterns that were confirmed by electrophysiological studies.
View Article and Find Full Text PDFBackground: Cardiac resynchronization therapy (CRT) with multipoint left ventricular (LV) pacing (MultiPoint™ Pacing [MPP], St. Jude Medical) improves acute LV function and LV reverse remodeling at 3 months.
Objective: The purpose of this study was to test the hypothesis that MPP can also improve LV function at 12 months.
J Cardiovasc Electrophysiol
January 2015
Introduction: Cardiac resynchronization therapy (CRT) with multipoint left ventricular (LV) pacing in a single coronary sinus branch improves acute LV function. We hypothesized that multipoint pacing (MPP) can improve midterm echocardiographic and clinical response compared with conventional CRT.
Methods And Results: Consecutive patients receiving a CRT implant (Unify Quadra MP™ or Quadra Assura MP™ CRT-D and Quartet™ LV lead, St.
Background: The management of Wolff-Parkinson-White is based on the distinction between asymptomatic and symptomatic presentations, but evidence is limited in the asymptomatic population.
Methods And Results: The Wolff-Parkinson-White registry was an 8-year prospective study of either symptomatic or asymptomatic Wolff-Parkinson-White patients referred to our Arrhythmology Department for evaluation or ablation. Inclusion criteria were a baseline electrophysiological testing with or without radiofrequency catheter ablation (RFA).
Background: Conventional cardiac resynchronization therapy (CRT) improves acute cardiac hemodynamics.
Objective: To investigate if CRT with multipoint left ventricular (LV) pacing in a single coronary sinus branch (MultiPoint Pacing [MPP], St Jude Medical, Sylmar, CA) can offer further hemodynamic benefits to patients.
Methods: Forty-four consecutive patients (80% men, New York Heart Association III, end-systolic volume 180 ± 77 mL, ejection fraction 27% ± 6%, and QRS duration 152 ± 17 ms) receiving a CRT device implant (Unify Quadra MP or Quadra Assura MP and Quartet LV lead, St Jude Medical) underwent intraoperative assessment of LV hemodynamics by using a pressure-volume loop system (Inca, CD Leycom).
The present case describes a patient with an implantable cardioverter-defibrillator (ICD) who reported several ICD inappropriate discharges due to transient T-wave oversensing in the setting of acute hyperkalemia. T-wave oversensing was detected only at telemetry interrogation while T-wave amplitude at surface 12-lead electrocardiogram was normal. Oversensing was abolished by reducing potassium levels and by device reprogramming.
View Article and Find Full Text PDFEven though platelet volume has been supposed to be indicator of platelet activation, contrasting results have been reported on its relationship with the extent of coronary artery disease (CAD). No data have been so far reported on Platelet-Large Cell Ratio (P-LCR). Thus, the aim of the current study was to investigate whether P-LCR is associated with CAD.
View Article and Find Full Text PDFBackground: Aortic valve sclerosis (AVS) is a marker of cardiovascular risk; its prevalence increases in elderly and in patients with hypertension and/or coronary arterial disease (CAD). There are no data available in patients with peripheral arterial disease (PAD) and with both CAD and PAD.
Methods: To investigate the presence of AVS, 57 patients with stable CAD, 38 with PAD, and 62 with CAD + PAD where studied by echocardiography.
Background: Left ventricular (LV) diastolic dysfunction is linked to myocardial collagen content in many cardiac diseases. There are no data regarding such relationship in patients with end-stage renal disease (ESRD) undergoing haemodialysis.
Methods: Twenty-five patients with ESRD undergoing haemodialysis were studied by echocardiography.
We present a case of a mechanical mitral valve thrombosis in a 37-year-old woman occurred 2 days after a Caesarean delivery. The patient stopped warfarin and initiated low-molecular-weight heparin 1 week before the programmed delivery. Subsequently the diagnosis of thrombosis, heparin infusion was started however unsuccessfully and eventually patient was referred for cardiac surgery.
View Article and Find Full Text PDF