Purpose: This study aims to investigate the influence of anterior chamber depth (ACD) and vault on the anterior chamber angle (ACA) morphology in myopic individuals implanted with posterior chamber phakic intraocular lenses.
Methods: This retrospective case series involved 231 eyes receiving a 13.2-mm implantable collamer lens (ICL).
Purpose: To determine the influence of implantable collamer lenses (ICL) geometry, i.e. spherical and toric on the vault, and report the refractive and visual outcomes of patients bilaterally implanted with the two ICL geometries.
View Article and Find Full Text PDFPurpose: To evaluate the influence of corneal tomographic and biomechanical indexes on the refractive technique indication.
Methods: A total of 251 eyes from 251 patients interested in refractive surgery were enrolled in this cross-sectional and multicenter study. Previous to the surgeon decision, a preoperative protocol was performed by refractive optometrists, containing four sections: refraction, biometry, corneal tomography and biomechanics.
Background: To identify biometric and implantable collamer lens (ICL)-related risk factors associated with sub-optimal postoperative vault in eyes implanted with phakic ICL.
Methods: This study reports a retrospective case series of the first operated eye in 360 patients implanted with myopic spherical or toric ICL. Preoperatively, white-to-white (WTW), central keratometry (Kc) and central corneal thickness (CCT) were measured using the Pentacam.
Purpose: The distance between an implantable collamer lens (ICL) and the crystalline lens, namely vault, is a space regulated by the interaction of the ICL and the anatomical structures of the eye. This study analysed the differences in vault size between fellow eyes with similar anterior segment biometry.
Patients And Methods: A retrospective case series analysed 109 cases of patients bilaterally implanted with EVO-V4c.
Purpose: To determine patient preoperative anatomical features and the parameters of implantable collamer lenses (ICLs) relevant in explaining vault variability.
Setting: Ophthalmology Clinic Vista Sánchez Trancón, Badajoz, Spain.
Design: Retrospective case series.
Purpose: Increased depth-of-focus after cataract surgery is dependent on various ocular characteristics, including refractive astigmatism. This work studied the influence of meridional blur produced by astigmatism, and spherical blur, on distance and near visual performance in pseudophakic eyes.
Methods: Visual performance was assessed monocularly in 59 pseudophakes (mean ± standard deviation, 66.