In this work, ten possible volatile biomarkers of lung cancer (acetone, 2-butanone, ethyl acetate, 2-pentanone, 4-methyl-2-pentanone, 2-hexanone, 3-heptanone, 2-heptanone, 3-octanone, and 2-nonanone) have been analyzed to evaluate their different concentration levels in urine samples from lung cancer patients (n = 12) and healthy controls (n = 12). The volatile compounds were generated with a headspace autosampler and analyzed with a gas chromatograph equipped with a programmed temperature vaporizer and mass spectrometry detector (HS-PTV-GC-MS). With the aim of evaluating the aforementioned differences, a Mann-Whitney U test and box-plots were obtained.
View Article and Find Full Text PDFA rapid method for the analysis of volatiles in saliva samples is proposed. The method is based on direct coupling of three components: a headspace sampler (HS), a programmable temperature vaporizer (PTV) and a quadrupole mass spectrometer (qMS). Several applications in the biomedical field have been proposed with electronic noses based on different sensors.
View Article and Find Full Text PDFAnal Bioanal Chem
July 2016
We propose a new method for the rapid determination of five volatile compounds described in the literature as possible biomarkers of lung cancer in urine samples. The method is based on the coupling of a headspace sampler, a programmed temperature vaporizer in solvent-vent injection mode, and a mass spectrometer (HS-PTV-MS). This configuration is known as an electronic nose based on mass spectrometry.
View Article and Find Full Text PDFA novel methodology for the determination of ornithine, putrescine, cadaverine, spermidine and gamma-amino butyric acid in urine samples has been developed. The method uses in situ aqueous derivatization followed by automated microextraction by packed sorbent coupled to a gas chromatography-mass spectrometry system equipped with a programmed temperature vaporizer. This instrumental configuration minimizes sample manipulation due to from the mixing of the reagents, the process is completely automated.
View Article and Find Full Text PDFAnal Chem
August 2014
With a view to improving the sensitivity of direct coupling of a headspace sampler (HS) with a mass spectrometer (MS), here we propose the use of a programmed temperature vaporizer (PTV) in solvent-vent injection mode before the sample is introduced into the MS. This preconcentration scheme has been used for some time in many methods based on gas chromatography (GC), but to the best of our knowledge it has not yet been used in an electronic nose based on MS. The increase in the S/N ratio with the proposed instrumental configuration (HS-PTV/MS) lies between 6.
View Article and Find Full Text PDF