Glioblastoma multiforme (GBM) is a rapidly growing tumor associated with poor prognosis. This study evaluates the effectiveness of thirteen tumor shape features for overall survival (OS) prognosis in GBM patients. Shape features were extracted from the abnormality regions of the GBM tumor visible on the fluid attenuated inversion recovery (FLAIR) and T1-weighted contrast enhanced (T1CE) MR images of GBM patients.
View Article and Find Full Text PDFThe electron cyclotron emission (ECE) diagnostic on the experimental advanced superconducting tokamak (EAST) was upgraded recently to provide electron temperature profile measurement with wider radial coverage and better precision. The lower limit of the ECE detection frequency band was extended from 104 GHz to 97 GHz by adding a new 8-channel heterodyne radiometer, which ensures capability for the measurement of the second harmonic ECE with toroidal magnetic field down to 1.75 T.
View Article and Find Full Text PDFA system to simultaneously diagnose the electron temperature and density fluctuations is proposed for Experimental Advanced Superconducting Tokamak device. This system includes a common quasi-optical antenna, a correlation electron cyclotron emission (CECE) system that is used to measure the electron temperature fluctuations and a Doppler backscattering (DBS) system that is used to measure the electron density fluctuations. The frequency range of the proposed CECE system is 108-120 GHz, and this corresponds to a radial coverage of normalized radius ((R - R)/a, R = 1850 mm, a = 450 mm) from 0.
View Article and Find Full Text PDFThe multi-channel visible bremsstrahlung measurement system has been developed on Experimental Advanced Superconducting Tokamak (EAST). In addition to providing effective ion charge Zeff as a routine diagnostic, this diagnostic can also be used to estimate other parameters. With the assumption that Zeff can be seen as constant across the radius and does not change significantly during steady state discharges, central electron temperature, averaged electron density, electron density profile, and plasma current density profile have been obtained based on the scaling of Zeff with electron density and the relations between Zeff and these parameters.
View Article and Find Full Text PDFElectron cyclotron emission reconstruction image has been used for flux surface reconstruction. The reconstruction image is based on plasma rigid rotation which is obtained from Mirnov diagnostic. From the reconstructed two-dimensional flux surface, the classical m/n = 3/2 mode is visualized, which is of similar spatial structure as neoclassical 3/2 mode observed in some other tokamaks [B.
View Article and Find Full Text PDF