Objectives: In an assessment of the risk of asbestos fibres release from asbestos cement materials, an important role is played by the assessment of the surface corrosion and by the disaggregation of asbestos cement. The aim of this work is to evaluate the differences among several methods used for the risk assessment that lead to a specific choice of abatement techniques.
Methods: The state of deterioration of 40 asbestos cement roofs was evaluated using two priority assessment algorithms elaborated in Italy, the 'pull-up test' described by the Italian Organization for Standardization and the indicators described in the Italian legislation coupled with the observation of a small sample, taken from each roof, by a stereomicroscope.