Left atrial appendage occlusion devices (LAAO) are a feasible alternative for non-valvular atrial fibrillation (AF) patients at high risk of thromboembolic stroke and contraindication to antithrombotic therapies. However, optimal LAAO device configurations (i.e.
View Article and Find Full Text PDFAm J Physiol Lung Cell Mol Physiol
December 2024
The intricate lung structure is crucial for gas exchange within the alveolar region. Despite extensive research, questions remain about the connection between capillaries and the vascular tree. We propose a computational approach combining three-dimensional (3-D) morphological modeling with computational fluid dynamics simulations to explore alveolar capillary network connectivity based on blood flow dynamics.
View Article and Find Full Text PDFAtrial fibrillation (AF) is the most common human arrhythmia, forming thrombi mostly in the left atrial appendage (LAA). However, the relation between LAA morphology, blood patterns and clot formation is not yet fully understood. Furthermore, the impact of anatomical structures like the pulmonary veins (PVs) have not been thoroughly studied due to data acquisition difficulties.
View Article and Find Full Text PDFComputational fluid dynamics (CFD) studies of left atrial flows have reached a sophisticated level, for example, revealing plausible relationships between hemodynamics and stresses with atrial fibrillation. However, little focus has been on fundamental fluid modeling of LA flows. The purpose of this study was to investigate the spatiotemporal convergence, along with the differences between high- (HR) versus normal-resolution/accuracy (NR) solution strategies, respectively.
View Article and Find Full Text PDFAdvanced visual computing solutions and three-dimensional (3D) printing are moving from engineering to clinical pipelines for training, planning, and guidance of complex interventions. 3D imaging and rendering, virtual reality (VR), and simulations, as well as 3D printing technologies provide complementary information to better understand the structure and function of the organs, thereby improving and personalizing clinical decisions. In this study, we evaluated several advanced visual computing solutions, such as web-based 3D imaging visualization, VR, and computational fluid simulations, together with 3D printing, for the planning of the left atrial appendage occluder (LAAO) device implantations.
View Article and Find Full Text PDFBackground: Atrial fibrillation (AF) is considered the most common human arrhythmia. In nonvalvular AF, around 99% of thrombi are formed in the left atrial appendage (LAA). Nevertheless, there is not a consensus in the community about the relevant factors to stratify the AF population according to thrombogenic risk.
View Article and Find Full Text PDFAccording to clinical studies, around one third of patients with atrial fibrillation (AF) will suffer a stroke during their lifetime. Between 70 and 90% of these strokes are caused by thrombus formed in the left atrial appendage. In patients with contraindications to oral anticoagulants, a left atrial appendage occluder (LAAO) is often implanted to prevent blood flow entering in the LAA.
View Article and Find Full Text PDFOsteoporotic bone fractures reduce quality of life and drastically increase mortality. Minimally irradiating imaging techniques such as dual-energy X-ray absorptiometry (DXA) allow assessment of bone loss through the use of bone mineral density (BMD) as descriptor. Yet, the accuracy of fracture risk predictions remains limited.
View Article and Find Full Text PDFThe left atrial appendage (LAA) is a complex and heterogeneous protruding structure of the left atrium (LA). In atrial fibrillation patients, it is the location where 90% of the thrombi are formed. However, the role of the LAA in thrombus formation is not fully known yet.
View Article and Find Full Text PDFChronic Obstructive Pulmonary Disease (COPD) is a disabling respiratory pathology, with a high prevalence and a significant economic and social cost. It is characterized by different clinical phenotypes with different risk profiles. Detecting the correct phenotype, especially for the emphysema subtype, and predicting the risk of major exacerbations are key elements in order to deliver more effective treatments.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2017
This work presents a multi-scale agent-based model of emphysema progression that includes both the slow action of the immune system and the fast action of force redistribution and fracture propagation of the biological tissue. The two scales are coupled because the immune response causes inflammation and adaptation, which affects the biomechanical parameters of the tissue such as his elasticity. During repeated inflammation and breathing cycles, the tissue weakens and breaks down.
View Article and Find Full Text PDFMotivation: Biological mechanisms contributing to atherogenesis are multiple and complex. The early stage of atherosclerosis (AS) is characterized by the accumulation of low-density lipoprotein (LDL) droplets, leading to the creation of foam cells (FC). To address the difficulty to explore the dynamics of interactions that controls this process, this study aimed to develop a model of agents and infer on the most influential cell- and molecule-related parameters.
View Article and Find Full Text PDFTissue Eng Part C Methods
August 2012
Cell seeding is a critical step in tissue engineering. A high number of cells evenly distributed in scaffolds after seeding are associated with a more functional tissue culture. Furthermore, high cell densities have shown the possibility to reduce culture time or increase the formation of tissue.
View Article and Find Full Text PDFIn natural tissues, the extracellular matrix composition, cell density and physiological properties are often non-homogeneous. Here we describe a model system, in which the distribution of cells throughout tissue engineering scaffolds after perfusion seeding can be influenced by the pore architecture of the scaffold. Two scaffold types, both with gyroid pore architectures, were designed and built by stereolithography: one with isotropic pore size (412 ± 13 μm) and porosity (62 ± 1%), and another with a gradient in pore size (250-500 μm) and porosity (35%-85%).
View Article and Find Full Text PDFApart from partial or total joint replacement, no surgical procedure is currently available to treat large and deep cartilage defects associated with advanced diseases such as osteoarthritis. In this work, we developed a perfusion bioreactor system to engineer human cartilage grafts in a size with clinical relevance for unicompartmental resurfacing of human knee joints (50 mm diameter × 3 mm thick). Computational fluid dynamics models were developed to optimize the flow profile when designing the perfusion chamber.
View Article and Find Full Text PDFTissue engineering scaffolds provide temporary mechanical support for tissue regeneration and transfer global mechanical load to mechanical stimuli to cells through its architecture. In this study the interactions between scaffold pore morphology, mechanical stimuli developed at the cell microscopic level, and culture conditions applied at the macroscopic scale are studied on two regular scaffold structures. Gyroid and hexagonal scaffolds of 55% and 70% porosity were modeled in a finite element analysis and were submitted to an inlet fluid flow or compressive strain.
View Article and Find Full Text PDF