Publications by authors named "Andrew W White"

Background: It is currently unknown whether primary CDs performed in compliance with the 2014 ACOG/SMFM Obstetric Care Consensus Statement guidelines ("guideline-compliant") are associated with a modified risk of maternal and neonatal morbidity, when compared to primary CDs performed outside the guidelines ("guideline-noncompliant"). Our primary objective was to determine if a guideline-compliant primary CD is associated with a modified risk for maternal or neonatal morbidity, when compared to guideline-noncompliant primary CD.

Methods: A retrospective cohort study of all primary CDs at one tertiary referral center in the calendar year following publication of the Consensus Statement.

View Article and Find Full Text PDF

This study identifies general characteristics of methods to estimate the absolute range between an acoustic transmitter and a receiver in the deep ocean. The data are from three days of the PhilSea10 experiment with a single fixed transmitter depth (∼998 m) and 150 receiver depths (∼210-5388 m) of known location, and a great-circle transmitter-receiver distance of ∼510 km. The proposed ranging methods compare observed acoustic records with synthetic records computed through the HYCOM (hybrid coordinate ocean model) model.

View Article and Find Full Text PDF

A mechanism is presented by which the observed acoustic intensity is made to vary due to changes in the acoustic path that are caused by internal-tide vertical fluid displacements. The position in range and depth of large-scale caustic structure is determined by the background sound-speed profile. Internal tides cause a deformation of the background profile, changing the positions of the caustic structures-which can introduce intensity changes at a distant receiver.

View Article and Find Full Text PDF

Observations of the spread of wander-corrected averaged pulses propagated over 510 km for 54 h in the Philippine Sea are compared to Monte Carlo predictions using a parabolic equation and path-integral predictions. Two simultaneous m-sequence signals are used, one centered at 200 Hz, the other at 300 Hz; both have a bandwidth of 50 Hz. The internal wave field is estimated at slightly less than unity Garrett-Munk strength.

View Article and Find Full Text PDF

Predictions of log-amplitude variance are compared against sample log-amplitude variances reported by White, Andrew, Mercer, Worcester, Dzieciuch, and Colosi [J. Acoust. Soc.

View Article and Find Full Text PDF

In the spring of 2009, broadband transmissions from a ship-suspended source with a 284-Hz center frequency were received on a moored and navigated vertical array of hydrophones over a range of 107 km in the Philippine Sea. During a 60-h period over 19,000 transmissions were carried out. The observed wavefront arrival structure reveals four distinct purely refracted acoustic paths: One with a single upper turning point near 80 m depth, two with a pair of upper turning points at a depth of roughly 300 m, and one with three upper turning points at 420 m.

View Article and Find Full Text PDF

This study (N = 384) presents results from outcome measurement in a services network providing specialized foster care (SFC) to children in child protective service custody. A majority of participants improved on most outcomes. Global improvement was associated with increased length of stay up to two years, five months, and with younger age, fewer problems, and, paradoxically, the presence of a trauma history.

View Article and Find Full Text PDF