The performance of a particle packed column will inevitably degrade through use or misadventure. 'Active flow technology' (AFT) is known to greatly improve the performance of pristine columns, but is as of yet untested when used on columns that have degraded significantly. In this study AFT was used to regenerate a degraded column, where the reduced plate height and asymmetry values were 3.
View Article and Find Full Text PDFActive Flow Technology (AFT) is a form of column technology that increases the separation performance of a HPLC column through the use of a specially purpose built multiport end-fitting(s). Curtain Flow (CF) columns belong to the AFT suite of columns, specifically the CF column is designed so that the sample is injected into the radial central region of the bed and a curtain flow of mobile phase surrounding the injection of solute prevents the radial dispersion of the sample to the wall. The column functions as an 'infinite diameter' column.
View Article and Find Full Text PDFA protocol for the use of reaction flow high performance liquid chromatography columns for methods employing post column derivatization (PCD) is presented. A major difficulty in adapting PCD to modern HPLC systems and columns is the need for large volume reaction coils that enable reagent mixing and then the derivatization reaction to take place. This large post column dead volume leads to band broadening, which results in a loss of observed separation efficiency and indeed detection in sensitivity.
View Article and Find Full Text PDFActive flow technology (AFT) is new form of column technology that was designed to overcome flow heterogeneity to increase separation performance in terms of efficiency and sensitivity and to enable multiplexed detection. This form of AFT uses a parallel segmented flow (PSF) column. A PSF column outlet end-fitting consists of 2 or 4 ports, which can be multiplexed to connect up to 4 detectors.
View Article and Find Full Text PDFA new type of chromatography column referred to as a parallel segmented flow (PSF) column enables ultra-high-speed high-performance liquid chromatography-MS to be undertaken. This occurs because the separation efficiency obtained on PSF columns has been shown in prior studies to be superior to conventional columns, and the flow stream is split radially inside the outlet end fitting of the column, rather than in an axial post-column flow stream split. As a result, the flow through the column can be five times higher than the flow through the MS.
View Article and Find Full Text PDFThe performance of active flow technology chromatography columns in parallel segmented flow mode packed with 5 μm Hypersil GOLD particles was compared to conventional UHPLC columns packed with 1.9 μm Hypersil GOLD particles. While the conventional UHPLC columns produced more theoretical plates at the optimum flow rate, when separations were performed at maximum through-put the larger particle size AFT column out-performed the UHPLC column.
View Article and Find Full Text PDFPost Column derivatisation (PCD) coupled with high performance liquid chromatography or ultra-high performance liquid chromatography is a powerful tool in the modern analytical laboratory, or at least it should be. One drawback with PCD techniques is the extra post-column dead volume due to reaction coils used to enable adequate reaction time and the mixing of reagents which causes peak broadening, hence a loss of separation power. This loss of efficiency is counter-productive to modern HPLC technologies, -such as UHPLC.
View Article and Find Full Text PDFIt has been shown that not only the packing homogeneity, but also factors external to the column bed, such as, frits and distributors can have important effects on the column performance. This current communication is the first in a series focusing on the impact of exogenous factors on the column bed heterogeneity. This study is based on several observations by us and others that chromatographic runs often, for technical reasons, include more or less portions of air in the injections.
View Article and Find Full Text PDFIn SFC the sample cannot be dissolved in the mobile phase, so it is often dissolved in pure modifier, or another liquid, sometimes resulting in serious distortions of the eluted peak profiles already at moderately high injection volumes. It is suspected the reasons for these effects are solvent strength mismatch and/or viscosity mismatch. This study presents a systematic and fundamental investigation of the origin of these peak deformations due to the injection solvent effects in SFC, using both systematic experiments and numerical modeling.
View Article and Find Full Text PDFAnalytical scale active flow technology first generation silica monolithic columns kitted out in curtain flow mode of operation were studied for the first time. A series of tests were undertaken assessing the column efficiency, peak asymmetry and detection sensitivity. Two curtain flow columns were tested, one with a fixed outlet ratio of 10% through the central exit port, the other with 30%.
View Article and Find Full Text PDFActive flow technology (AFT) columns are designed to minimise inefficient flow processes associated with the column wall and radial heterogeneity of the stationary phase bed. This study is the first to investigate AFT on an analytical scale 4.6mm internal diameter first-generation silica monolith.
View Article and Find Full Text PDFThe effects of column length on performance in segmented flow chromatography were tested. Column efficiencies were measured for 4.6mm I.
View Article and Find Full Text PDFHerein we assess the separation space offered by a liquid chromatography system with an optimised uni-dimensional separation for the determination of the key chemical entities in the highly complex matrix of a tobacco leaf extract. Multiple modes of detection, including UV-visible absorbance, chemiluminescence (acidic potassium permanganate, manganese(IV), and tris(2,2'-bipyridine)ruthenium(III)), mass spectrometry and DPPH radical scavenging were used in an attempt to systematically reduce the data complexity of the sample whilst obtaining a greater degree of molecule-specific information. A large amount of chemical data was obtained, but several limitations in the ability to assign detector responses to particular compounds, even with the aid of complementary detection systems, were observed.
View Article and Find Full Text PDFWe describe a new approach to multiplex detection for HPLC, exploiting parallel segmented outlet flow - a new column technology that provides pressure-regulated control of eluate flow through multiple outlet channels, which minimises the additional dead volume associated with conventional post-column flow splitting. Using three detectors: one UV-absorbance and two chemiluminescence systems (tris(2,2'-bipyridine)ruthenium(III) and permanganate), we examine the relative responses for six opium poppy (Papaver somniferum) alkaloids under conventional and multiplexed conditions, where approximately 30% of the eluate was distributed to each detector and the remaining solution directed to a collection vessel. The parallel segmented outlet flow mode of operation offers advantages in terms of solvent consumption, waste generation, total analysis time and solute band volume when applying multiple detectors to HPLC, but the manner in which each detection system is influenced by changes in solute concentration and solution flow rates must be carefully considered.
View Article and Find Full Text PDFHeroin (3,6-diacetylmorphine) and several important extraction and synthesis impurities (morphine, 6-monoacetylmorphine, codeine and 6-acetylcodeine) were determined in illicit drug samples, using high performance liquid chromatography with 'parallel segmented flow', which enabled the simultaneous use of three complementary modes of detection (UV-absorbance, tris(2,2'-bipyridine)ruthenium(III) chemiluminescence and permanganate chemiluminescence). This rapid and sensitive approach for the analysis of street heroin was used to explore the chemistry of a proposed heroin screening test that is based on the relative response with these two chemiluminescence reagents using flow injection analysis. Although heroin was the major constituent of the six drug samples (between 16% and 67% by mass), the synthetic by-product 6-acetylcodeine (2.
View Article and Find Full Text PDFRationale: Speed of analysis is a significant limitation to current high-performance liquid chromatography/mass spectrometry (HPLC/MS) and ultra-high-pressure liquid chromatography (UHPLC)/MS systems. The flow rate limitations of MS detection require a compromise in the chromatographic flow rate, which in turn reduces throughput, and when using modern columns, a reduction in separation efficiency. Commonly, this restriction is combated through the post-column splitting of flow prior to entry into the mass spectrometer.
View Article and Find Full Text PDFActive flow management in the form of curtain flow sample introduction and segmented outlet flow control has been shown to enable sample to elute through a chromatography column under the principles of the "infinite diameter column". Such an elution process avoids the detrimental effects of the heterogeneity of particle-packed chromatographic columns by injecting the sample directly into the radial core region of the column, thus avoiding wall effects. The process described herein illustrates how the principles of the infinite diameter column can be applied using conventional injection devices suitable for long-term analysis that requires robust protocols.
View Article and Find Full Text PDFActive Flow Management is a new separation technique whereby the flow of mobile phase and the injection of sample are introduced to the column in a manner that allows migration according to the principles of the infinite diameter column. A segmented flow outlet fitting allows for the separation of solvent or solute that elutes along the central radial section of the column from that of the sample or solvent that elutes along the wall region of the column. Separation efficiency on the analytical scale is increased by 25% with an increase in sensitivity by as much as 52% compared to conventional separations.
View Article and Find Full Text PDFA new column technology - termed parallel segmented outlet flow was employed here to illustrate gains in separation performance that are achievable by the active management of flow as it exits from the outlet of the chromatography column. Parallel segmented outlet flow requires a column be fitted with an outlet fitting that separates flow from the central region of the column from that of wall region. Each region of flow is able to be processed independently, such that post column detection emulates end column localised detection.
View Article and Find Full Text PDFComprehensive multidimensional separations are today dominated by systems that are fundamentally limited to highly asymmetrical online separations sacrificing separation space, or to lengthy, time consuming offline separations. With the exception of pulse-modulated methods, separations have thus been limited to two dimensions. It is proposed that some of the limitations and shortcomings of these methods may be ameliorated or overcome by employing multi-dimensional detection whereby each analyte is effectively labelled in the frequency domain by a series of pulsed-injections, and a symmetrical, comprehensive online analysis performed with the resulting signal processed by sequential Fourier analysis.
View Article and Find Full Text PDFThe multidimensional high-performance liquid chromatography separations of the complex sample matrix found in café espresso coffee were completed on the propyl phenyl and butyl phenyl columns that contain 3 and 4 carbon atoms in the spacer chain, respectively. Phenyl type stationary phases are able to undergo unique π-π interactions with aromatic compounds. Previous works have found that there are differences in retention characteristics between these chain lengths and this was explored further here.
View Article and Find Full Text PDFThe use of high performance liquid chromatography with acidic potassium permanganate chemiluminescence detection to screen for antioxidants in complex plant-derived samples was evaluated in comparison with two conventional post-column radical scavenging assays (2,2-diphenyl-1-picrylhydrazyl radical (DPPH) and 2,2'-azinobis-(3-ethylbenzothiazoline-6-sulfonic acid) radical cation (ABTS(+))). In this approach, acidic potassium permanganate can react with readily oxidisable compounds (potential antioxidants), post-column, to produce chemiluminescence. Using flow injection analysis, experimental parameters that afforded the most suitable permanganate chemiluminescence signal for a range of known antioxidants were studied in a univariate approach.
View Article and Find Full Text PDFPower transformations are commonly used in image processing techniques to manipulate image contrast. Many analytical results, including chromatograms, are essentially presented as images, often to convey qualitative information. Power transformations have remarkable effects on the appearance of the image, in chromatography, for example, increasing apparent resolution between peaks by the factor √n and apparent column efficiency (plate counts) by a factor of n for an nth-power transform.
View Article and Find Full Text PDF