Publications by authors named "Andrew Schluchter"

Purpose: Standard four-dimensional computed tomography (4DCT) cardiac reconstructions typically include spiraling artifacts that depend not only on the motion of the heart but also on the gantry angle range over which the data was acquired. We seek to reduce these motion artifacts and, thereby, improve the accuracy of left ventricular wall positions in 4DCT image series.

Methods: We use a motion artifact reduction approach (ResyncCT) that is based largely on conjugate pairs of partial angle reconstruction (PAR) images.

View Article and Find Full Text PDF

Purpose: We demonstrate the viability of a four-dimensional X-ray computed tomography (4DCT) imaging system to accurately and precisely estimate mechanical activation times of left ventricular (LV) wall motion. Accurate and reproducible timing estimates of LV wall motion may be beneficial in the successful planning and management of cardiac resynchronization therapy (CRT).

Methods: We developed an anthropomorphically accurate in silico LV phantom based on human CT images with programmed septal-lateral wall dyssynchrony.

View Article and Find Full Text PDF

Background: Modern computed tomographic scanning can produce 4-dimensional images of the left atrial appendage (LAA). LAA function and morphology can then be measured, to plan interventions such as occlusion and to evaluate LAA flow for thrombogenic risk analysis. A current problem here is defining a reproducible boundary between the LAA and the left atrium.

View Article and Find Full Text PDF

We present an anthropomorphically accurate left ventricular (LV) phantom derived from human computed tomography (CT) data to serve as the ground truth for the optimization and the spatial resolution quantification of a CT-derived regional strain metric (SQUEEZ) for the detection of regional wall motion abnormalities. Displacements were applied to the mesh points of a clinically derived end-diastolic LV mesh to create analytical end-systolic poses with physiologically accurate endocardial strains. Normal function and regional dysfunction of four sizes [1, 2/3, 1/2, and 1/3 American Heart Association (AHA) segments as core diameter], each exhibiting hypokinesia (70% reduction in strain) and subtle hypokinesia (40% reduction in strain), were simulated.

View Article and Find Full Text PDF

Purpose: Coronary x-ray computed tomography angiography (CCTA) continues to develop as a noninvasive method for the assessment of coronary vessel geometry and the identification of physiologically significant lesions. The uncertainty of quantitative lesion diameter measurement due to limited spatial resolution and vessel motion reduces the accuracy of CCTA diagnoses. In this paper, we introduce a new technique called computed tomography (CT)-number-Calibrated Diameter to improve the accuracy of the vessel and stenosis diameter measurements with CCTA.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionkti3rromfgieq4mgtaok93lqdfnaa111): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once