Background: PEEP is titrated to improve oxygenation during mechanical ventilation. It is clinically desirable to identify factors that are associated with a clinical improvement or deterioration following a PEEP change. However, these factors have not been adequately described in the literature.
View Article and Find Full Text PDFObjectives: Increases in positive end-expiratory pressure are implemented to improve oxygenation through the recruitment and stabilization of collapsed alveoli. However, the time it takes for a positive end-expiratory pressure change to have maximum effect upon oxygenation and pulmonary compliance has not been adequately described in children. Therefore, we sought to quantify the time required for oxygenation and pulmonary system compliance changes in children requiring mechanical ventilation.
View Article and Find Full Text PDFPurpose: Many pacifier companies advertise that their product is the "best choice" to support proper sucking, feeding, and dental development; however, very little evidence exists to support these claims. As the primary differences across pacifiers are structural and mechanical, the goals of this study were to measure such properties of commercially available pacifiers and to examine how these properties alter suck patterning in healthy, full-term infants.
Method: Seven commonly utilized pacifiers were mechanically tested for pull and compression stiffness levels and categorized into nipple shape types based on their aspect ratio.
Proc Math Phys Eng Sci
August 2017
The impact mechanics of micrometre-scale metal particles with flat metal surfaces is investigated for high-velocity impacts ranging from 50 m s to more than 1 km s, where impact causes predominantly plastic deformation. A material model that includes high strain rate and temperature effects on the yield stress, heat generation due to plasticity, material damage due to excessive plastic strain and heat transfer is used in the numerical analysis. The coefficient of restitution is predicted by the classical work using elastic-plastic deformation analysis with quasi-static impact mechanics to be proportional to [Formula: see text] and [Formula: see text] for the low and moderate impact velocities that span the ranges of 0-10 and 10-100 m s, respectively.
View Article and Find Full Text PDFBackground: Although effective in the neonatal population, exogenous pulmonary surfactant has not demonstrated a benefit in pediatric and adult subjects with hypoxic lung injury despite a sound physiologic rationale. Importantly, neonatal surfactant replacement therapy is administered in conjunction with low fractional F while pediatric/adult therapy is administered with high F . We suspected a connection between F and surfactant performance.
View Article and Find Full Text PDFPurpose: High-frequency airway clearance therapy is a positive pressure secretion clearance modality used in pediatric and adult applications. However, pressure attenuation across different size endotracheal tubes (ETT) has not been adequately described. This study quantifies attenuation in an in vitro model.
View Article and Find Full Text PDFDetection of changes in micrographia as a manifestation of symptomatic progression or therapeutic response in Parkinson's disease (PD) is challenging as such changes can be subtle. A computerized toolkit based on quantitative analysis of handwriting samples would be valuable as it could supplement and support clinical assessments, help monitor micrographia, and link it to PD. Such a toolkit would be especially useful if it could detect subtle yet relevant changes in handwriting morphology, thus enhancing resolution of the detection procedure.
View Article and Find Full Text PDFJPEN J Parenter Enteral Nutr
May 2015
Thermally sprayed ceramics, when infiltrated with polymer, exhibit synergistic increases in strength and toughness. The structure of such composites-a dense, brick-mortar arrangement-is strikingly similar to that of nacre, as are the mechanisms underlying the robust mechanical behavior. This industrial-scale process thus presents an exciting tool for bio-mimetic exploration.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
May 2012
Lung imaging and assessment of alveoli geometry in the lung tissue is of great importance. Optical coherence tomography (OCT) is a real-time imaging technique used for this purpose, based on near-infrared interferometry, that can image several layers of distal alveoli in the lung tissue. The OCT measurements use low coherence interferometry, where light reflections from surfaces in the tissue are used to construct 2D images of the tissue.
View Article and Find Full Text PDFA multiscale, multiphysics model generates synthetic images of alveolar compression under spherical indentation at the visceral pleura of an inflated lung. A mechanical model connects the millimeter scale of an indenter tip to the behavior of alveoli, walls, and membrane at the micrometer scale. A finite-difference model of optical coherence tomography (OCT) generates the resulting images.
View Article and Find Full Text PDFA flexible, low-cost, high-brightness light source for biological and biomedical imaging is presented. The illuminating device consists of a custom-size square plastic pouch 10 to 20 mm on a side and 1 to 3 mm thick that can be inserted fully or partially into both in situ or in vitro specimens to be imaged. The pouch contains a silicone-based gel medium embedded with silica particles that scatters light and provides a reasonably uniform, planar light source.
View Article and Find Full Text PDFHyaluronan (HA) is a natural polysaccharide abundant in biological tissues and it can be modified to prepare biomaterials. In this work, HA modified with glycidyl methacrylate was photocrosslinked to form the first network (PHA), and then a series of highly porous PHA/N,N-dimethylacrylamide (DAAm) hydrogels (PHA/DAAm) with high mechanical strength were obtained by incorporating a second network of photocrosslinked DAAm into PHA network. Due to the synergistic effect produced by double network (DN) structure, despite containing 90% of water, the resulting PHA/DAAm hydrogel showed a compressive modulus and a fracture stress over 0.
View Article and Find Full Text PDFTo function normally, the lungs, heart, and other organs must undergo changes in shape and size, sliding against surrounding body walls. It is not known whether the delicate mesothelial surfaces covering these organs and body wall are in contact during sliding, or if hydrodynamic pressure in the lubricating liquid increases separation between their surfaces. To address this question, we measured the coefficient of friction (mu) of the mesothelial surface of nine rat-abdominal walls sliding in saline on a smooth glass surface.
View Article and Find Full Text PDFJ Appl Physiol (1985)
December 2003
To address the role of the parietal pleura in reduction of mesothelial shear stresses during breathing, we measured the stiffness of the parietal pleural surface of mammalian chest walls using microindentation. The pleural surface was indented over ribs and intercostal spaces with rigid flat punches (tip radii of 0.01, 0.
View Article and Find Full Text PDFRespir Physiol Neurobiol
August 2003
To examine effects of lung motion on the separation of pleural surfaces during breathing, we modeled the pleural space in two dimensions as a thin layer of fluid separating a stationary elastic solid and a sliding flat solid surface. The undeformed elastic solid contained a series of bumps, to represent tissue surface features, introducing unevenness in fluid layer thickness. We computed the extent of deformation of the solid as a function of sliding velocity, solid elastic modulus, and bump geometry (wavelength and amplitude).
View Article and Find Full Text PDFWe describe a novel synchronous detection approach to map the transmission of mechanical stresses within the cytoplasm of an adherent cell. Using fluorescent protein-labeled mitochondria or cytoskeletal components as fiducial markers, we measured displacements and computed stresses in the cytoskeleton of a living cell plated on extracellular matrix molecules that arise in response to a small, external localized oscillatory load applied to transmembrane receptors on the apical cell surface. Induced synchronous displacements, stresses, and phase lags were found to be concentrated at sites quite remote from the localized load and were modulated by the preexisting tensile stress (prestress) in the cytoskeleton.
View Article and Find Full Text PDFRespir Physiol Neurobiol
August 2002
The pleural space is modeled in two dimensions as a thin layer of fluid separating a deformable membrane and a rigid surface containing a bump. We computed the steady-state membrane configuration and fluid pressure distribution during relative sliding of the two surfaces. For physiologically relevant values of membrane tension, shear flow-induced pressures near the bump and far-field pressure gradients are similar to those measured in vivo within the pleural space (e.
View Article and Find Full Text PDF