Publications by authors named "Andrew Copland"

Background And Aims: Gastric variceal bleeding occurs less commonly than bleeding from esophageal varices (EVs), although it is associated with higher morbidity and mortality. Bleeding from gastroesophageal varices type 1 (GOV1) is treated like EVs. In contrast, other forms of gastric variceal bleeding, including gastroesophageal varices type 2 (GOV2) and isolated gastric varices types 1 (IGV1) and 2 (IGV2), are treated with varying endoscopic approaches.

View Article and Find Full Text PDF
Submucosal injection fluid and tattoo agents.

Gastrointest Endosc

November 2024

Background And Aims: EMR and endoscopic submucosal dissection (ESD) are minimally invasive endoscopic techniques, developed for the removal of benign and early malignant lesions throughout the GI tract. Submucosal injection of a marking agent can help to identify lesions during surgery. Endoscopic resection frequently involves "lifting" of the lesions by injection of a substance within the submucosal space to create a cushion for safe resection.

View Article and Find Full Text PDF

Description: In this Clinical Practice Update (CPU), we provide guidance on the appropriate use of different polypectomy techniques. We focus on polyps <2 cm in size that are most commonly encountered by the practicing endoscopist, including use of classification systems to characterize polyps and various polypectomy methods. We review characteristics of polyps that require complex polypectomy techniques and provide guidance on which types of polyps require more advanced management by a therapeutic endoscopist or surgeon.

View Article and Find Full Text PDF

Introduction: Technical burdens and time-intensive review processes limit the practical utility of video capsule endoscopy (VCE). Artificial intelligence (AI) is poised to address these limitations, but the intersection of AI and VCE reveals challenges that must first be overcome. We identified five challenges to address.

View Article and Find Full Text PDF

Background And Aims: Esophageal function testing is an integral component of the evaluation of refractory GERD and esophageal motility disorders. This review summarizes the current technologies available for esophageal function testing, including the functional luminal imaging probe (FLIP), high-resolution esophageal manometry (HRM), and multichannel intraluminal impedance (MII) and pH monitoring.

Methods: We performed a MEDLINE, PubMed, and MAUDE database literature search to identify pertinent clinical studies through March 2021 using the following key words: esophageal manometry, HRM, esophageal impedance, FLIP, MII, and esophageal pH testing.

View Article and Find Full Text PDF
Article Synopsis
  • Video capsule endoscopy (VCE) is a minimally invasive method that allows doctors to thoroughly examine the entire gastrointestinal tract by capturing real-time images as the capsule travels through it.
  • While VCE provides detailed images for diagnosis, analyzing up to eight hours of footage can be labor-intensive and costly, suggesting a need for automation.
  • The study compared four deep learning models for identifying the anatomical regions in VCE images, finding that VGG-Net outperformed others like GoogLeNet, AlexNet, and ResNet in accuracy and other performance metrics.
View Article and Find Full Text PDF

Background And Aims: Endoscopic management of acute cholecystitis has expanded in patients who are considered nonoperative candidates. Traditionally managed with percutaneous cholecystostomy (PC), improvement in techniques and devices has led to increased use of endoscopic methods for gallbladder drainage. This document reviews technical aspects of endoscopic transpapillary gallbladder drainage (ET-GBD) and EUS-guided GBD (EUS-GBD) as well as their respective technical/clinical success and adverse event rates.

View Article and Find Full Text PDF
Lumen-apposing metal stents (with videos).

Gastrointest Endosc

September 2021

Background And Aims: Lumen-apposing metal stents (LAMSs) are a novel class of devices that have expanded the spectrum of endoscopic GI interventions. LAMSs with their dumbbell configuration, short saddle length, and large inner luminal diameter provide favorable stent characteristics to facilitate anastomosis formation between the gut lumen and adjacent structures.

Methods: The MEDLINE database was searched through April 2021 for articles related to LAMSs by using additional relevant keywords such as "walled-off pancreatic necrosis," "pseudocysts," "pancreatic fluid collection," "cholecystitis," "gastroenterostomy," in addition to "endoscopic treatment" and "endoscopic management," among others.

View Article and Find Full Text PDF

Background And Aims: Multidrug-resistant infectious outbreaks associated with duodenoscopes have been documented internationally. Single-use duodenoscopes, disposable distal ends, or distal end cap sealants could eliminate or reduce exogenous patient-to-patient infection associated with ERCP.

Methods: This document reviews technologies that have been developed to help reduce or eliminate exogenous infections because of duodenoscopes.

View Article and Find Full Text PDF

A subcommittee of the Association for Bariatric Endoscopy, a division of the American Society for Gastrointestinal Endoscopy (ASGE) comprising experts in the subject area, performed this systematic review and meta-analysis. The systematic review and meta-analysis was reviewed by the ASGE Technology Committee and was ultimately submitted to the ASGE Governing Board for approval. The systematic review and meta-analysis underwent peer review by outside experts in statistics and meta-analysis before receiving final ASGE Governing Board approval.

View Article and Find Full Text PDF

An over-the-scope clip is a type of endoscopically placed clip used to treat gastrointestinal perforation, bleeding, or fistula. After the defect heals, the clip usually passes uneventfully through the gastrointestinal tract. An uncommon complication of over-the-scope clip placement is intestinal obstruction caused by luminal stenosis at the site of clip placement.

View Article and Find Full Text PDF

Background: Video capsule endoscopy provides noninvasive visualization of the small bowel, but yield is often limited by debris. At our institution, preparation with polyethylene glycol (PEG) and simethicone is used to improve visualization.

Aims: We hypothesized that linaclotide and simethicone would yield equal to better results.

View Article and Find Full Text PDF

Purpose Of Review: Investigation of the esophageal microbiome is a relatively new field. This review will outline data characterizing the esophageal microbiome in both health and disease states, including gastroesophageal reflux disease (GERD), Barrett's esophagus, esophageal cancer, eosinophilic esophagitis, and motility disorders.

Recent Findings: While the esophagus was previously considered devoid of a significant bacterial population, development of culture-independent techniques, specifically 16S rRNA gene sequencing, as well as novel, minimally invasive microbial sampling modalities, has facilitated characterization of the esophageal microbiome in both health and several disease states.

View Article and Find Full Text PDF

Cytomegalovirus (CMV) can precipitate and exacerbate gastrointestinal (GI) mucosal injury. The gold standard for CMV detection in formalin-fixed, paraffin-embedded (FFPE) tissue is immunohistochemistry (IHC). Although CMV polymerase chain reaction (PCR) on fresh tissue may be a valuable adjunct to IHC, its utility is unknown for FFPE tissues.

View Article and Find Full Text PDF

Background: Vital signs are critical data in the care of hospitalized patients, but the accuracy with which respiratory rates are recorded in this population remains uncertain. We used a novel flash mob research approach to evaluate the accuracy of recorded respiratory rates in inpatients.

Methods: This was a single-day, resident-led, prospective observational study of recorded vs directly observed vital signs in nonventilated patients not in the ICU on internal medicine teaching services at six large tertiary-care centers across the United States.

View Article and Find Full Text PDF

Background: Tandem colonoscopy is regarded as the reference standard for the evaluation of the adenoma detection rate (ADR) and adenoma miss rate (AMR) during colonoscopy. Pooled results from previous tandem studies yield AMRs of 22%. The AMR of trainees is important to estimate the number of colonoscopies required to develop competence in screening for colorectal neoplasms.

View Article and Find Full Text PDF