Publications by authors named "Andrew Bowdle"

Mechanomyography is currently the accepted laboratory reference standard for quantitative neuromuscular blockade monitoring. Mechanomyographs are not commercially available. Previously, a mechanomyograph was built by our laboratory and used in several clinical studies.

View Article and Find Full Text PDF

Background: The accuracy and precision of currently available, widely used acceleromyograph and electromyograph neuromuscular blockade monitors have not been well studied. In addition, the normalization of the train-of-four ratio from acceleromyography (train-of-four ratio [T4/T1] divided by the baseline train-of-four ratio) has not been validated in comparison to mechanomyography.

Methods: Enrolled patients had surgery under general anesthesia with a supraglottic airway and without any neuromuscular blocking drugs.

View Article and Find Full Text PDF

The COVID-19 pandemic has transformed our understanding of aerosol transmissible disease and the measures required to minimise transmission. Anaesthesia providers are often in close proximity to patients and other hospital staff for prolonged periods while working in operating and procedure rooms. Although enhanced ventilation provides some protection from aerosol transmissible disease in these work areas, close proximity and long duration of exposure have the opposite effect.

View Article and Find Full Text PDF

Commercial aviation practices including the role of the pilot monitoring, the sterile flight deck rule, and computerised checklists have direct applicability to anaesthesia care. The pilot monitoring performs specific tasks that complement the pilot flying who is directly controlling the aircraft flight path. The anaesthesia care team, with two providers, can be organised in a manner that is analogous to the two-pilot flight deck.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to compare the Stimpod electromyograph neuromuscular blockade monitor to mechanomyography, which is widely considered to be the reference standard.

Methods: The Stimpod electromyograph was used with its designated electrode array on the same hand as the mechanomyograph. Pairs of train-of-four measurements were recorded every 0.

View Article and Find Full Text PDF

Background: Millions of catheters for invasive arterial pressure monitoring are placed annually in intensive care units, emergency rooms, and operating rooms to guide medical treatment decision-making. Accurate assessment of arterial blood pressure requires an IV pole-attached pressure transducer placed at the same height as a reference point on the patient's body, typically, the heart. Every time a patient moves, or the bed is adjusted, a nurse or physician must adjust the height of the pressure transducer.

View Article and Find Full Text PDF

Background: Mechanomyography is the traditional gold standard research technique for quantitative assessment of neuromuscular blockade. Mechanomyography directly measures the isometric force generated by the thumb in response to ulnar nerve stimulation. Researchers must construct their own mechanomyographs since commercial instruments are no longer available.

View Article and Find Full Text PDF

Background: The dose of sugammadex recommended by the manufacturer for reversal of rocuronium is 2 mg/kg when the train-of-four count is 2 or more and 4 mg/kg when it is less than 2 but there is a posttetanic count of at least 1. The purpose of this dose-finding study was to titrate sugammadex to produce a train-of-four ratio 0.9 or greater at the conclusion of cardiac surgery, and to continue monitoring neuromuscular blockade in the intensive care unit to identify recurrent paralysis.

View Article and Find Full Text PDF

An error in the administration of an anaesthetic medication related to an automated dispensing cabinet resulted in a patient fatality and a highly publicised criminal prosecution of a healthcare worker, which concluded in 2022. Urgent action is required to re-engineer systems and workflows to prevent such errors. Exhortation, blame, and criminal prosecution are unlikely to advance the cause of patient safety.

View Article and Find Full Text PDF

Commercially available bite blocks used for invasive imaging procedures have design limitations, including bulky profile, being made of hard plastic that may damage surrounding tissue, and tendency to dislodge. We designed a novel bite block to address these limitations and evaluated this bite block in 50 patients undergoing diagnostic or intraprocedural transesophageal echocardiography examinations. Nine of 11 (82%) imagers who used the redesigned bite block preferred it over the standard bite block used at our institution.

View Article and Find Full Text PDF

Respiratory viruses are transmitted via respiratory particles that are emitted when people breath, speak, cough, or sneeze. These particles span the size spectrum from visible droplets to airborne particles of hundreds of nanometers. Barrier face coverings ("cloth masks") and surgical masks are loose-fitting and provide limited protection from airborne particles since air passes around the edges of the mask as well as through the filtering material.

View Article and Find Full Text PDF