Turk J Anaesthesiol Reanim
April 2018
Objective: During assisted ventilation and spontaneous breathing, functional haemodynamic parameters, including stroke volume variation (SVV) and pulse pressure variation (PPV), are of limited value to predict fluid responsiveness, and the passive leg raising (PLR) manoeuvre has been advocated as a surrogate method. We aimed to study the predictive value of SVV, PPV and PLR for fluid responsiveness during weaning from mechanical ventilation after cardiac surgery.
Methods: Haemodynamic variables and fluid responsiveness were assessed in 34 patients.
Objective: The aim of this study was to analyze the accuracy, precision, and trending ability of the following 4 pulse wave analysis devices to measure continuous cardiac output: PiCCO ([PCCO]; Pulsion Medical System, Munich, Germany); LiDCO ([LCCO]; LiDCO Ltd, London, UK); FloTrac/Vigileo ([FCCO]; Edwards Lifesciences, Irvine, CA); and Nexfin ([NCCO]; BMEYE, Amsterdam, The Netherlands).
Design: Prospective, observational clinical study.
Setting: Intensive care unit of a single-center, teaching hospital.
Introduction: Out of hospital cardiac arrest (OHCA) occurs frequently and the outcome is often dismal. Early defibrillation saves lives and brain function in OHCA. The Zurich city police (STAPO) forces were instructed and equipped to provide basic life support (BLS) and to use an AED in 2009.
View Article and Find Full Text PDFWe describe the first case of a pregnant woman presenting with an acute inverted takotsubo-like cardiomyopathy caused by a postpartum diagnosed hemorrhagic pheochromocytoma, successfully treated with percutaneous venoarterial extracorporeal membrane oxygenation (va-ECMO). During admission, an emergency cesarean delivery had to be performed. The fetus needed resuscitation for 5 minutes.
View Article and Find Full Text PDFBackground: The benefit of the post-anaesthesia care unit (PACU) with respect to an early detection of postoperative complications is beyond dispute. From a patient perspective, prevention and optimal management of pain, nausea and vomiting (PONV) are also of utmost importance. The aims of the study were therefore to prospectively measure pain and PONV on arrival to the PACU and before discharge and to determine the relationship of pain and PONV to the length of stay in the PACU.
View Article and Find Full Text PDFAnasthesiol Intensivmed Notfallmed Schmerzther
February 2012
The variety of minimally invasive cardiac output (CO) monitoring devices is growing rendering it difficult to keep track of new developments. In this article technical principles, limitations and validation procedures considering new aspects are reviewed. An integrated approach for their use is proposed since no single device can comply with all clinical needs.
View Article and Find Full Text PDFBy measuring the ocular pulse amplitude (OPA), the dynamic contour tonometer (DCT) assesses intraocular pressure (IOP). Hypothesizing that OPA is characteristic for the IOP when considered with the systemic arterial blood pressure, we assumed the ratio of ocular and arterial pulsation amplitudes is larger in glaucoma patients. Bi-ocular DCT-OPA assessment was synchronized with arterial pulsations using Finapres® technology, thereby enabling blood pressure determination for each corresponding IOP value every 0.
View Article and Find Full Text PDFExpert Rev Med Devices
September 2010
Platelets play a central role in primary hemostasis. Analysis of platelet function is therefore a cornerstone in the global assessment of the coagulation status in the perioperative setting, primarily in patients receiving antiplatelet medication, such as cyclooxygenase-1 inhibitors, adenosine diphosphate antagonists and glycoprotein IIb/IIIa inhibitors. In these patients, knowledge of residual platelet function is highly warranted in order to maintain an optimal and individual balance perioperatively between platelet function and inhibition - that is, bleeding and thrombosis.
View Article and Find Full Text PDFIntroduction: Open, right-sided, transthoracic esophagectomy with one-lung ventilation (OLV) triggers a massive inflammatory reaction. The influence of the OLV on the inflammatory cascade is unclear. Data on the inflammatory response in the ventilated left and collapsed right lung, respectively, are scarce.
View Article and Find Full Text PDFObjectives: Arterial pressure waveform analysis is a less invasive alternative to the pulmonary artery catheter for continuous cardiac output (CO) measurement. Uncalibrated and calibrated systems are actually available (ie, the FloTrac/Vigileo system [Edwards Lifesciences, Irvine, CA] and the PiCCOplus system [Pulsion Medical Systems, Munich, Germany]). According to the FloTrac/Vigileo manufacturer, reliable measurements can be performed using any existing arterial catheter.
View Article and Find Full Text PDFIntroduction: The FloTrac/Vigileo (Edwards Lifesciences, Irvine, CA, USA) allows pulse pressure-derived cardiac output measurement without external calibration. Software modifications were performed in order to eliminate initially observed deficits. The aim of this study was to assess changes in cardiac output determined by the FloTrac/Vigileo system (FCO) with an initially released (FCOA) and a modified (FCOB) software version, as well as changes in cardiac output from the PiCCOplus system (PCO; Pulsion Medical Systems, Munich, Germany).
View Article and Find Full Text PDFA 37-yr-old patient scheduled for elective bursectomy developed fulminant malignant hyperthermia (MH) under sevoflurane anesthesia. The first sign was a dramatic increase in end-tidal CO(2). Symptomatic and specific therapy was rapidly instituted.
View Article and Find Full Text PDFObjectives: Recombinant activated factor VII (rFVIIa) is increasingly being given to treat massive bleeding. However, there is no clear guidance on which patients are suitable for treatment and how the effects of treatment should be monitored. The aim of this in vitro study was to assess the coagulation status of severely hemodiluted blood samples before and after treatment with therapeutic doses of rFVIIa and/or fibrinogen with 2 viscoelastic point-of-care coagulation analyzers: ROTEM (Pentapharm GmbH, Munich, Germany) and Sonoclot (Sienco Inc, Arvada, CO).
View Article and Find Full Text PDFIntroduction: Stroke volume variation (SVV) has repeatedly been shown to be a reliable predictor of fluid responsiveness. Various devices allow automated clinical assessment of SVV. The aim of the present study was to compare prediction of fluid responsiveness using SVV, as determined by the FloTrac/Vigileo system and the PiCCOplus system.
View Article and Find Full Text PDFObjectives: The aim of this study was to compare the following approaches to assess left ventricular preload by transesophageal echocardiography (TEE): left ventricular end-diastolic volume index (LVEDVI) determined by using the method of disc summation (LVEDVI(Md)) and left ventricular end-diastolic area index (LVEDAI) were compared with LVEDVI assessed by the modified Simpson formula (LVEDVI(Si)). Global end-diastolic volume index (GEDVI) and stroke volume index (SVI) measured by the PiCCO(plus) system (Pulsion Medical Systems, Munich, Germany) were used as TEE-independent reference variables.
Design: Prospective observational study.
Study Objectives: To continuously measure arterial blood gases (ABGs), to calculate the percentage of anticipated changes over time, and to develop recommendations for sampling frequencies of arterial blood gases in patients undergoing thoracoscopic surgery.
Design: Prospective, observational clinical trial.
Setting: University hospital.
Objectives: In vivo data for the kaolin-based ACT test from the Sonoclot Analyzer (SkACT, Sienco Inc, Arvada, CO) are lacking. The aim of this study was to compare SkACT with an established kaolin-based ACT from Hemochron (HkACT) and anti-Xa activity in patients undergoing cardiopulmonary bypass (CPB).
Design: Prospective observational study.
Background: Neuraxial blockade is used as primary anesthetic technique in one third of surgical procedures. The authors tested whether bisoprolol would protect patients at risk for cardiovascular complications undergoing surgery with spinal block.
Methods: The authors performed a double-blinded, placebo-controlled, multicenter trial to compare the effect of bisoprolol with that of placebo on 1-yr composite outcome including cardiovascular mortality, nonfatal myocardial infarction, unstable angina, congestive heart failure, and cerebrovascular insult.
Purpose Of Review: Several less invasive cardiac output monitoring techniques are now commercially available and have the potential to replace the pulmonary artery catheter under certain clinical circumstances. The aim of this review is to give a synopsis of the currently available cardiac output measurement methods. This information should help in selecting the appropriate technique in a particular clinical setting.
View Article and Find Full Text PDFBackground: Anesthetic gases modulate gene expression and provide organ protection. This study aimed at identifying myocardial transcriptional phenotypes to predict cardiovascular biomarkers and function in patients undergoing off-pump coronary artery bypass graft surgery.
Methods: In a prospective randomized trial, patients undergoing elective off-pump coronary artery bypass graft surgery were allocated to receive either the anesthetic gas sevoflurane (n = 10) or the intravenous anesthetic propofol (n = 10).
Objective: Reliable platelet function monitoring is desirable in patients treated with glycoprotein IIb/IIIa receptor inhibitors. The aim of the present laboratory-based study was to assess platelet function after administration of clinically relevant doses of the glycoprotein IIb/IIIa antagonist tirofiban with or without heparin by using Sonoclot (Sienco Inc) and platelet aggregometry.
Methods: Tirofiban (0-100 ng x mL(-1)) and heparin (0 or 1 U x mL(-1)) were added to blood samples obtained from 20 healthy volunteers.