Pointwise transinformation (PTI) provides a quantitative nonlinear approach to spatiotemporal synchronization patterns of the rhythms of coupled cortical oscillators. We applied PTI to the waking and sleep EEGs of 21 healthy sleepers; we calculated the mean levels and distances of synchronized episodes and estimated the dominant frequency shift from unsynchronized to synchronized EEG segments by spectral analysis. Recurrent EEG synchronization appeared and ceased abruptly in the anterior, central, and temporal derivations; in the posterior derivations it appeared more fluctuating.
View Article and Find Full Text PDFThe osteointegration rate of titanium (Ti; TI01) and duplex Ti plus HA (HT01) coating systems with high surface roughness was investigated in healthy, aged, and oestrogen-deficient sheep. After having evaluated the bone quality, TI01 and HT01 rods were implanted in the tibial diaphyses (two implants for each tibia) and epiphyses (1 implant for each tibia) of five young (YOUNG), five aged (AGED), and five aged and ovariectomized (OVX) sheep. The iliac crest trabecular bone volume (BV/TV) and number (Tb.
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
November 2005
The aim of this study was to characterize and compare various titanium (Ti) and hydroxyapatite (HA) coatings on Ti6Al4V, in view of their application on noncemented orthopedic implants. Two innovative vacuum plasma sprayed (VPS) coatings, the first of ultrahigh rough and dense Ti (PG60, Ra=74 microm) and the second of ultrahigh rough and dense Ti coated with HA (HPG60, Ra=52 microm), have been developed, and the response of osteoblast-like cells (MG-63) seeded on these new coatings was evaluated in comparison to: a low roughness and sandblasted (Ti/SA, Ra=4 microm) Ti6Al4V surface; Ti medium (TI01, Ra=18 microm), and high (TI60, Ra=40 microm) roughness VPS coatings; and the relative Ti plus HA duplex coatings (HT01, Ra=12 microm and HT60, Ra=36 microm respectively), also obtained by VPS. PG60 coating presented no open porosity, making it dense and potentially intrinsically stronger.
View Article and Find Full Text PDFA new implant surface has been developed with the purpose of avoiding as much stress shielding as possible, and thus prolong the prosthesis lifespan. The aim of this study was to investigate the in vitro effect of this new ultra-high roughness and dense Titanium (Ti) surface (PG60, Ra = 74 microm) in comparison with medium (TI01, Ra = 18 microm) and high (TI60, Ra = 40 microm) roughness and open porous coatings; all the coatings were obtained by vacuum plasma spraying. MG63 osteoblast-like cells were seeded on the tested materials and polystyrene, as control, for 3 and 7 days.
View Article and Find Full Text PDF